Alert monitor for Lenovo BladeCenter power module DC faults

IBM.BladeCenter.PowerModuleDC.Failed (UnitMonitor)


Alert monitor for Lenovo BladeCenter power module DC faults

Element properties:

TargetIBM.BladeCenter.PowerModule
Parent MonitorSystem.Health.AvailabilityState
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityMatchMonitorHealth
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeIBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModule
RemotableTrue
AccessibilityPublic
Alert Message
Lenovo BladeCenter power module DC faults

{0} -- EventID = {1}
RunAsDefault

Source Code:

<UnitMonitor ID="IBM.BladeCenter.PowerModuleDC.Failed" Accessibility="Public" Enabled="true" Target="IBM.BladeCenter.PowerModule" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="IBM.BladeCenter.SNMPTrap.3StateMonitorTypeForModule" ConfirmDelivery="false">
<Category>Custom</Category>
<AlertSettings AlertMessage="IBM.BladeCenter.PowerModuleDC.Failed.AlertMessageID">
<AlertOnState>Warning</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/SnmpVarBinds/SnmpVarBind[OID='.1.3.6.1.4.1.2.6.158.3.1.1.8']/Value$</AlertParameter1>
<AlertParameter2>$Data/Context/SnmpVarBinds/SnmpVarBind[OID='.1.3.6.1.4.1.2.6.158.3.1.1.14']/Value$</AlertParameter2>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="ComponentSuccess" MonitorTypeStateID="SuccessEventRaised" HealthState="Success"/>
<OperationalState ID="ComponentWarning" MonitorTypeStateID="WarningEventRaised" HealthState="Warning"/>
<OperationalState ID="ComponentError" MonitorTypeStateID="ErrorEventRaised" HealthState="Error"/>
</OperationalStates>
<Configuration>
<EventIds>134381569|13438157[0-2]</EventIds>
</Configuration>
</UnitMonitor>