Alert monitor for Lenovo Flex System Chassis Node power denied due to power budget

IBM.FlexSystem.BladePowerBudget.Denied (UnitMonitor)


Alert monitor for Lenovo Flex System Chassis Node power denied due to power budget

Element properties:

TargetIBM.FlexSystem.BladeModule
Parent MonitorSystem.Health.AvailabilityState
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityMatchMonitorHealth
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeIBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModule
RemotableTrue
AccessibilityPublic
Alert Message
Lenovo Flex System Chassis Node power denied due to power budget

{0} -- EventID = {1}
RunAsDefault

Source Code:

<UnitMonitor ID="IBM.FlexSystem.BladePowerBudget.Denied" Accessibility="Public" Enabled="true" Target="IBM.FlexSystem.BladeModule" ParentMonitorID="Health!System.Health.AvailabilityState" Remotable="true" Priority="Normal" TypeID="IBM.FlexSystem.SNMPTrap.3StateMonitorTypeForModule" ConfirmDelivery="false">
<Category>Custom</Category>
<AlertSettings AlertMessage="IBM.FlexSystem.BladePowerBudget.Denied.AlertMessageID">
<AlertOnState>Warning</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>MatchMonitorHealth</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/SnmpVarBinds/SnmpVarBind[OID='.1.3.6.1.4.1.2.6.158.3.1.1.8']/Value$</AlertParameter1>
<AlertParameter2>$Data/Context/SnmpVarBinds/SnmpVarBind[OID='.1.3.6.1.4.1.2.6.158.3.1.1.14']/Value$</AlertParameter2>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="ComponentSuccess" MonitorTypeStateID="SuccessEventRaised" HealthState="Success"/>
<OperationalState ID="ComponentWarning" MonitorTypeStateID="WarningEventRaised" HealthState="Warning"/>
<OperationalState ID="ComponentError" MonitorTypeStateID="ErrorEventRaised" HealthState="Error"/>
</OperationalStates>
<Configuration>
<EventIds>25170739[3-9]|25170740[0-6]</EventIds>
</Configuration>
</UnitMonitor>