Health rollup of Lenovo hardware components

IBM.SystemX.HWComponent.Health.Rollup (DependencyMonitor)


Health rollup of Lenovo hardware components

Element properties:

TargetIBM.SystemX.BaseSystem
Parent MonitorSystem.Health.EntityState
AlgorithmWorstOf
Source MonitorSystem.Health.EntityState
RelationshipIBM.Relation.SystemX.HWComponentVsBaseSystem
CategoryCustom
EnabledTrue
Alert GenerateFalse
Alert Auto ResolveFalse
RemotableTrue
AccessibilityPublic

Source Code:

<DependencyMonitor ID="IBM.SystemX.HWComponent.Health.Rollup" Accessibility="Public" Enabled="true" Target="IBM.SystemX.BaseSystem" ParentMonitorID="Health!System.Health.EntityState" Remotable="true" Priority="Normal" RelationshipType="IBM.Relation.SystemX.HWComponentVsBaseSystem" MemberMonitor="Health!System.Health.EntityState">
<Category>Custom</Category>
<Algorithm>WorstOf</Algorithm>
<MemberUnAvailable>Error</MemberUnAvailable>
</DependencyMonitor>