LC:USrv - 25 - Conference Mcu Allocator\USrv - 011 - Factory Call Latency (msec)\ perf counter exceeded specified threshold. Current value is {0}
The average time (in milliseconds) taken to complete a MCU factory call.
The Mcu factory might be busy and may not respond immediately.
This might be a temporary condition. If the problem persists please ensure that the hardware and software requirements meet the user usage characteristics.
Target | Microsoft_Office_Communications_Server_2007_R2_Standard_Edition | ||
Parent Monitor | System.Health.PerformanceState | ||
Category | PerformanceHealth | ||
Enabled | True | ||
Instance Name | LC:USrv - 25 - Conference Mcu Allocator | ||
Counter Name | USrv - 011 - Factory Call Latency (msec) | ||
Frequency | 900 | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | System.Performance.ThresholdMonitorType | ||
Remotable | True | ||
Accessibility | Public | ||
Alert Message |
| ||
RunAs | Default |
<UnitMonitor ID="LC_USrv___25___Conference_Mcu_Allocator_USrv___011___Factory_Call_Latency__msec___5000__SE" Accessibility="Public" Enabled="true" Target="Microsoft_Office_Communications_Server_2007_R2_Standard_Edition" ParentMonitorID="SCHealth!System.Health.PerformanceState" Remotable="true" Priority="Normal" TypeID="SCPerformance!System.Performance.ThresholdMonitorType" ConfirmDelivery="false">
<Category>PerformanceHealth</Category>
<AlertSettings AlertMessage="LC_USrv___25___Conference_Mcu_Allocator_USrv___011___Factory_Call_Latency__msec_______The_average_time__in_milliseconds__taken_to_complete_a_MCU_factory_call_">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
</AlertSettings>
<OperationalStates>
<OperationalState ID="LC_USrv___25___Conference_Mcu_Allocator_USrv___011___Factory_Call_Latency__msec___5000__SE_OverThreshold" MonitorTypeStateID="OverThreshold" HealthState="Error"/>
<OperationalState ID="LC_USrv___25___Conference_Mcu_Allocator_USrv___011___Factory_Call_Latency__msec___5000__SE_UnderThresold" MonitorTypeStateID="UnderThreshold" HealthState="Success"/>
</OperationalStates>
<Configuration>
<ComputerName>$Target/Host/Property[Type="SCWindowsLibrary!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<CounterName>USrv - 011 - Factory Call Latency (msec)</CounterName>
<ObjectName>LC:USrv - 25 - Conference Mcu Allocator</ObjectName>
<InstanceName/>
<AllInstances>false</AllInstances>
<Frequency>900</Frequency>
<Threshold>5000</Threshold>
</Configuration>
</UnitMonitor>