MECM Site component manager fails to read Active Directory objects Event Rule

MECM.SiteComponentManager.CanNotFindObjectInAD.Event.Rule (Rule)

This rule generates alerts if the site component manager fails to read objects in Active Directory.

Knowledge Base article:

Summary

This rule generates an alert if the site component manager fails to read objects in Active Directory.

Causes

Resolutions

Element properties:

TargetMECM.SiteComponentManager
CategoryEventCollection
EnabledTrue
Event_ID4909
Event SourceSMS Server
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
RemotableTrue
Alert Message
MECM Failed to read Active Directory alert
The site server failed to read objects in Active Directory.
Event Description: {0}
Event LogApplication

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
Alert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="MECM.SiteComponentManager.CanNotFindObjectInAD.Event.Rule" Enabled="true" Target="MECM.SiteComponentManager" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Application</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">4909</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">SMS Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="Alert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>2</Severity>
<AlertName/>
<AlertDescription/>
<AlertOwner/>
<AlertMessageId>$MPElement[Name="MECM.SiteComponentManager.CanNotFindObjectInAD.Event.Rule.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
<Custom1/>
<Custom2/>
<Custom3/>
<Custom4/>
<Custom5/>
<Custom6/>
<Custom7/>
<Custom8/>
<Custom9/>
<Custom10/>
</WriteAction>
</WriteActions>
</Rule>