Failed to update the Topology configuration. The service will remain in the broken state until the corrected Topology has been republished.
The new topology likely contains errors.
Review the topology for possible errors or restart the service to see if the problem persists.
Target | Microsoft.LS.2019.Component.DataConf | ||
Category | EventCollection | ||
Enabled | True | ||
Event_ID | 41022 | ||
Event Source | LS Data MCU | ||
Alert Generate | True | ||
Alert Severity | Warning | ||
Alert Priority | Low | ||
Remotable | True | ||
Alert Message |
| ||
Event Log | Lync Server |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
CollectEvent | DataSource | Microsoft.Windows.EventProvider | Default |
WriteAlert | WriteAction | System.Health.GenerateAlert | Default |
WriteToDB | WriteAction | Microsoft.SystemCenter.CollectEvent | Default |
WriteToDW | WriteAction | Microsoft.SystemCenter.DataWarehouse.PublishEventData | Default |
<Rule ID="Microsoft.LS.2019.Monitoring.Rule.InfoEvent.DataConf.EVENT_DATAMCU_TOPOLOGY_UPDATE_FAIL" Enabled="true" Target="SFBDiscovery!Microsoft.LS.2019.Component.DataConf" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="CollectEvent" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Lync Server</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">LS Data MCU</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">41022</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="WriteToDB" TypeID="SC!Microsoft.SystemCenter.CollectEvent"/>
<WriteAction ID="WriteAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>0</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Alert_Failed_to_update_the_Topology_configuration._The_service_will_remain_in_the_broken_state_until_the_corrected_Topology_has_been_republished."]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue>$Data/EventDisplayNumber$</SuppressionValue>
<SuppressionValue>$Data/PublisherName$</SuppressionValue>
<SuppressionValue>$Data/LoggingComputer$</SuppressionValue>
</Suppression>
</WriteAction>
<WriteAction ID="WriteToDW" TypeID="SCDW!Microsoft.SystemCenter.DataWarehouse.PublishEventData"/>
</WriteActions>
</Rule>