連續取樣模組初始化失敗

Microsoft.SystemCenter.ConsecutiveSamplesModule.FailedInitialization.Alert (Rule)

當連續取樣模組發生初始化失敗時,此規則會產生警示。

Knowledge Base article:

摘要

連續取樣模組初始化時發生錯誤。 因此該模組會卸載,造成相關規則也跟著卸載。

原因

失敗的發生可能是由多種原因所造成。 失敗相關資訊可於相關事件中取得。

失敗的原因可能是:

.

解決方式

檢查相關事件描述,識別並更正造成問題的設定。

作法有:

Element properties:

TargetMicrosoft.SystemCenter.HealthService
CategoryAlert
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityNormal
RemotableTrue
Alert Message
連續取樣模組無法初始化
{0}
Event LogOperations Manager

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="Microsoft.SystemCenter.ConsecutiveSamplesModule.FailedInitialization.Alert" Enabled="true" Target="SCLibrary!Microsoft.SystemCenter.HealthService" ConfirmDelivery="true" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/NetworkName$</ComputerName>
<LogName>Operations Manager</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">Health Service Modules</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<Value Type="String">$Target/ManagementGroup/Name$</Value>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<XPathQuery Type="String">Params/Param[1]</XPathQuery>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">10110</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDescription</XPathQuery>
</ValueExpression>
<Operator>ContainsSubstring</Operator>
<Pattern>ConsecutiveSamples</Pattern>
</RegExExpression>
</Expression>
</And>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>1</Priority>
<Severity>1</Severity>
<AlertMessageId>$MPElement[Name="Microsoft.SystemCenter.ConsecutiveSamplesModule.FailedInitialization.AlertMessage"]$</AlertMessageId>
<AlertParameters>
<AlertParameter1>$Data/EventDescription$</AlertParameter1>
</AlertParameters>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>