Data Warehouse Health Service Availability (Heartbeat) Synchronization State Reader Recovery State

Microsoft.SystemCenter.DataWarehouse.Synchronization.HealthServiceOutage.StateReadState.RecoveryState (UnitMonitor)

This monitor switches to warning state once Data Warehouse health service availability (heartbeat) synchronization state reader process experiences a problem and does not recover from that problem in a configured amount of time

Element properties:

TargetMicrosoft.SystemCenter.DataWarehouseSynchronizationService
Parent MonitorMicrosoft.SystemCenter.DataWarehouse.Synchronization.HealthServiceOutage.StateReadState.Rollup
CategoryStateCollection
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeMicrosoft.SystemCenter.DataWarehouse.2SingleEventLogTimed2StateUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Data Warehouse health service availability data synchronization process failed to read state
Data Warehouse health service availability data synchronization process failed to read state from the Data Warehouse database. {0}
RunAsDefault

Source Code:

<UnitMonitor ID="Microsoft.SystemCenter.DataWarehouse.Synchronization.HealthServiceOutage.StateReadState.RecoveryState" Accessibility="Internal" Enabled="true" Target="Microsoft.SystemCenter.DataWarehouseSynchronizationService" ParentMonitorID="Microsoft.SystemCenter.DataWarehouse.Synchronization.HealthServiceOutage.StateReadState.Rollup" TypeID="DataWarehouse!Microsoft.SystemCenter.DataWarehouse.2SingleEventLogTimed2StateUnitMonitorType" ConfirmDelivery="true">
<Category>StateCollection</Category>
<AlertSettings AlertMessage="Microsoft.SystemCenter.DataWarehouse.Synchronization.HealthServiceOutage.StateReadState.AlertMessage">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Item0Context/DataItem/EventDescription$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="Good" MonitorTypeStateID="SecondEventRaised" HealthState="Success"/>
<OperationalState ID="Bad" MonitorTypeStateID="FirstEventRaisedAndNoSecondEventRaisedInTimeInterval" HealthState="Error"/>
</OperationalStates>
<Configuration>
<WorkflowName>Microsoft.SystemCenter.DataWarehouse.Synchronization.HealthServiceOutage</WorkflowName>
<FirstEventId>31557</FirstEventId>
<SecondEventId>31558</SecondEventId>
<TimeIntervalSeconds>300</TimeIntervalSeconds>
</Configuration>