Windows Physical Disk Discovery

Microsoft.Windows.Server.2008.PhysicalDiskDiscovery.ModuleType (DataSourceModuleType)

Element properties:

TypeDataSourceModuleType
IsolationAny
AccessibilityInternal
RunAsSystem.PrivilegedMonitoringAccount
OutputTypeSystem.Discovery.Data

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource System.CommandExecuterDiscoveryDataSource Default

Overrideable Parameters:

IDParameterTypeSelectorDisplay NameDescription
IntervalSecondsint$Config/IntervalSeconds$Interval Seconds
TimeoutSecondsint$Config/TimeoutSeconds$Timeout Seconds

Source Code:

<DataSourceModuleType ID="Microsoft.Windows.Server.2008.PhysicalDiskDiscovery.ModuleType" RunAs="System!System.PrivilegedMonitoringAccount" Accessibility="Internal">
<Configuration>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="ComputerName" type="xsd:string"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="ComputerID" type="xsd:string"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="IntervalSeconds" type="xsd:integer"/>
<xsd:element xmlns:xsd="http://www.w3.org/2001/XMLSchema" name="TimeoutSeconds" type="xsd:int"/>
</Configuration>
<OverrideableParameters>
<OverrideableParameter ID="IntervalSeconds" Selector="$Config/IntervalSeconds$" ParameterType="int"/>
<OverrideableParameter ID="TimeoutSeconds" ParameterType="int" Selector="$Config/TimeoutSeconds$"/>
</OverrideableParameters>
<ModuleImplementation>
<Composite>
<MemberModules>
<DataSource ID="DS" TypeID="System!System.CommandExecuterDiscoveryDataSource">
<IntervalSeconds>$Config/IntervalSeconds$</IntervalSeconds>
<ApplicationName>%windir%\System32\cscript.exe</ApplicationName>
<WorkingDirectory/>
<CommandLine>$file/DiscoverWindows2008PhysicalDisks.vbs$ $MPElement$ $Target/Id$ $Config/ComputerName$ $Config/ComputerID$</CommandLine>
<TimeoutSeconds>$Config/TimeoutSeconds$</TimeoutSeconds>
<RequireOutput>true</RequireOutput>
<Files>
<File>
<Name>DiscoverWindows2008PhysicalDisks.vbs</Name>
<Contents><Script>
'Copyright (c) Microsoft Corporation. All rights reserved.

' Parameters that should be passed to this script
' 0 MPElement ID ($MPElement$)
' 1 Target Id for ME this rule is running against ($Target/Id$)
' 2 Computer (FQDN) that the Physical Disk will be hosted on
' 3 Computer ID (Key) that the Physical Disk will be hosted on

Option Explicit
SetLocale("en-us")

' WMI Constants
Const wbemCimtypeUseDefault = 0 'Use Default Type CIM type - Custom
Const wbemCimtypeSint16 = 2 'Signed 16-bit integer
Const wbemCimtypeSint32 = 3 'Signed 32-bit integer
Const wbemCimtypeReal32 = 4 '32-bit real number
Const wbemCimtypeReal64 = 5 '64-bit real number
Const wbemCimtypeString = 8 'String
Const wbemCimtypeBoolean = 11 'Boolean value
Const wbemCimtypeObject = 13 'CIM object
Const wbemCimtypeSint8 = 16 'Signed 8-bit integer
Const wbemCimtypeUint8 = 17 'Unsigned 8-bit integer
Const wbemCimtypeUint16 = 18 'Unsigned 16-bit integer
Const wbemCimtypeUint32 = 19 'Unsigned 32-bit integer
Const wbemCimtypeSint64 = 20 'Signed 64-bit integer
Const wbemCimtypeUint64 = 21 'Unsigned 64-bit integer
Const wbemCimtypeDatetime = 101 'Date/time value
Const wbemCimtypeReference = 102 'Reference to a CIM object
Const wbemCimtypeChar16 = 103 '16-bit character

Const ErrAction_None = 0
Const ErrAction_Trace = 1
Const ErrAction_ThrowError = 16
Const ErrAction_Abort = 32
Const ErrAction_ThrowErrorAndAbort = 48

Call Main()

Sub Main()

Dim oArgs
Set oArgs = WScript.Arguments
if oArgs.Count &lt;&gt; 4 Then
Quit()
End If

Dim SourceID, ManagedEntityId, TargetComputer, TargetComputerID

SourceID = oArgs(0)
ManagedEntityId = oArgs(1)
TargetComputer = oArgs(2)
TargetComputerID = oArgs(3)


Dim oAPI, oDiscoveryData

Set oAPI = MOMCreateObject("MOM.ScriptAPI")
set oDiscoveryData = oAPI.CreateDiscoveryData(0, SourceID, ManagedEntityId)

If DoDiscovery(TargetComputer, TargetComputerID, oDiscoveryData) &gt;= 0 Then
Call oAPI.Return(oDiscoveryData)
Else
Quit()
End If

End Sub

Function DoDiscovery(ByVal sTargetComputer, ByVal sTargetComputerID, ByVal oDisc)

Dim WMISet, owObj, oDiskInstance
Set WMISet = WMIGetInstance("winmgmts:\\" + sTargetComputer + "\root\cimv2", "Win32_DiskDrive")
for each owObj in WMISet
Set oDiskInstance = oDisc.CreateClassInstance("$MPElement[Name='Microsoft.Windows.Server.2008.PhysicalDisk']$")
With oDiskInstance
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.Computer']/PrincipalName$", sTargetComputerID
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.LogicalDevice']/DeviceID$", GetWMIProperty(owObj, "DeviceID", wbemCimtypeUseDefault, ErrAction_Abort)
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.LogicalDevice']/Name$", GetWMIProperty(owObj, "Name", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='Windows!Microsoft.Windows.LogicalDevice']/Description$", GetWMIProperty(owObj, "Description", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/Caption$", GetWMIProperty(owObj, "Caption", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/Index$", GetWMIProperty(owObj, "Index", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/InterfaceType$", GetWMIProperty(owObj, "InterfaceType", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/Manufacturer$", GetWMIProperty(owObj, "Manufacturer", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/Model$", GetWMIProperty(owObj, "Model", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/SCSIBus$", GetWMIProperty(owObj, "SCSIBus", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/SCSILogicalUnit$", GetWMIProperty(owObj, "SCSILogicalUnit", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/SCSIPort$", GetWMIProperty(owObj, "SCSIPort", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/SCSITargetID$", GetWMIProperty(owObj, "SCSITargetID", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/Size$", GetWMIProperty(owObj, "Size", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/TotalCylinders$", GetWMIProperty(owObj, "TotalCylinders", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/TotalHeads$", GetWMIProperty(owObj, "TotalHeads", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/TotalSectors$", GetWMIProperty(owObj, "TotalSectors", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/TotalTracks$", GetWMIProperty(owObj, "TotalTracks", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/TracksPerCylinder$", GetWMIProperty(owObj, "TracksPerCylinder", wbemCimtypeUseDefault, ErrAction_None)
.AddProperty "$MPElement[Name='WindowsServer!Microsoft.Windows.Server.PhysicalDisk']/PerfmonInstance$", GetPerfmonInstance(sTargetComputer, GetWMIProperty(owObj, "DeviceID", wbemCimtypeUseDefault, ErrAction_None),GetWMIProperty(owObj, "Index", wbemCimtypeUseDefault, ErrAction_Abort))
.AddProperty "$MPElement[Name='System!System.Entity']/DisplayName$", "Disk " + GetWMIProperty(owObj, "Index", wbemCimtypeUseDefault, ErrAction_None)
End With
call oDisc.AddInstance(oDiskInstance)
next
DoDiscovery = 0
End Function


Function WMIGetObject(ByVal sNamespace)
'
' WMIGetObject :: Returns the WMI object requested.
'
'
Dim oWMI
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" &amp; sNamespace &amp; "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If

Set WMIGetObject = oWMI

End Function



Function WMIGetInstance(ByVal sNamespace, ByVal sInstance)
'
' WMIGetInstance :: Returns WMI Instance requested.
'
'
Dim oWMI, oInstance, nInstanceCount
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" &amp; sNamespace &amp; "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If

On Error Resume Next
Set oInstance = oWMI.InstancesOf(sInstance)
e.Save
On Error Goto 0
If IsEmpty(oInstance) Or e.Number &lt;&gt; 0 Then
ThrowScriptError "The class name '" &amp; sInstance &amp; "' returned no instances. Please check to see if this is a valid WMI class name.", e
End If

'Determine if we queried a valid WMI class - Count will return 0 or empty

On Error Resume Next
nInstanceCount = oInstance.Count
e.Save
On Error Goto 0
If e.Number &lt;&gt; 0 Then
ThrowScriptError "The class name '" &amp; sInstance &amp; "' did not return any valid instances. Please check to see if this is a valid WMI class name.", e
End If

Set WMIGetInstance = oInstance

End Function

Function WMIExecQuery(ByVal sNamespace, ByVal sQuery)
'
' WMIExecQuery :: Executes the WMI query and returns the result set.
'
'
Dim oWMI, oQuery, nInstanceCount
Dim e
Set e = New Error
On Error Resume Next
Set oWMI = GetObject(sNamespace)
e.Save
On Error Goto 0
If IsEmpty(oWMI) Then
ThrowScriptError "Unable to open WMI Namespace '" &amp; sNamespace &amp; "'. Check to see if the WMI service is enabled and running, and ensure this WMI namespace exists.", e
End If

On Error Resume Next
Set oQuery = oWMI.ExecQuery(sQuery)
e.Save
On Error Goto 0
If IsEmpty(oQuery) Or e.Number &lt;&gt; 0 Then
ThrowScriptError "The Query '" &amp; sQuery &amp; "' returned an invalid result set. Please check to see if this is a valid WMI Query.", e
End If

'Determine if we queried a valid WMI class - Count will return 0 or empty
On Error Resume Next
nInstanceCount = oQuery.Count
e.Save
On Error Goto 0
If e.Number &lt;&gt; 0 Then
ThrowScriptError "The Query '" &amp; sQuery &amp; "' did not return any valid instances. Please check to see if this is a valid WMI Query.", e
End If

Set WMIExecQuery = oQuery

End Function

Function WMIGetInstanceNoAbort(ByVal sNamespace, ByVal sInstance)
'
' WMIGetInstanceNoAbort :: Returns WMI Instance requested.
'
'
Dim oWMI, oInstance, nInstanceCount

On Error Resume Next
Set oWMI = GetObject(sNamespace)
If Not IsEmpty(oWMI) Then

Set oInstance = oWMI.InstancesOf(sInstance)
If Not IsEmpty(oInstance) And Err.Number = 0 Then

'Determine if we queried a valid WMI class - Count will return 0 or empty
nInstanceCount = oInstance.Count
If Err.Number = 0 Then
Set WMIGetInstanceNoAbort = oInstance
Exit Function
End If
End If
End If
On Error Goto 0

Set WMIGetInstanceNoAbort = Nothing

End Function

Function GetWMIProperty(oWmi, sPropName, nCIMType, ErrAction)
Dim sValue, oWmiProp

If Not IsValidObject(oWmi) Then
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "Accessing property on invalid WMI object.", Err

If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()

GetWMIProperty = ""
Exit Function
End If

On Error Resume Next
Set oWmiProp = oWmi.Properties_.Item(sPropName)
If Err.Number &lt;&gt; 0 Then
If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "An error occurred while accessing WMI property: '" &amp; sPropName &amp; "'.", Err

If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()
End If
On Error Goto 0

If IsValidObject(oWmiProp) Then
sValue = oWmiProp.Value

If IsNull(sValue) Then
'
' If value is null, return blank to avoid any issues
'
GetWMIProperty = ""

Else

Select Case (oWmiProp.CIMType)
Case wbemCimtypeString, wbemCimtypeSint16, wbemCimtypeSint32, wbemCimtypeReal32, wbemCimtypeReal64, wbemCimtypeSint8, wbemCimtypeUint8, wbemCimtypeUint16, wbemCimtypeUint32, wbemCimtypeSint64, wbemCimtypeUint64:
If Not oWmiProp.IsArray Then
GetWMIProperty = Trim(CStr(sValue))
Else
GetWMIProperty = Join(sValue, ", ")
End If
Case wbemCimtypeBoolean:
If sValue = 1 Or UCase(sValue) = "TRUE" Then
GetWMIProperty = "True"
Else
GetWMIProperty = "False"
End If
Case wbemCimtypeDatetime:

Dim sTmpStrDate

'
' First attempt to convert the whole wmi date string
'
sTmpStrDate = Mid(sValue, 5, 2) &amp; "/" &amp; _
Mid(sValue, 7, 2) &amp; "/" &amp; _
Left(sValue, 4) &amp; " " &amp; _
Mid (sValue, 9, 2) &amp; ":" &amp; _
Mid(sValue, 11, 2) &amp; ":" &amp; _
Mid(sValue, 13, 2)
If IsDate(sTmpStrDate) Then
GetWMIProperty = CDate(sTmpStrDate)
Else

'
' Second, attempt just to convert the YYYYMMDD
'
sTmpStrDate = Mid(sValue, 5, 2) &amp; "/" &amp; _
Mid(sValue, 7, 2) &amp; "/" &amp; _
Left(sValue, 4)
If IsDate(sTmpStrDate) Then
GetWMIProperty = CDate(sTmpStrDate)
Else
'
' Nothing works - return passed in string
'
GetWMIProperty = sValue
End If

End If

Case Else:
GetWMIProperty = ""
End Select
End If
Else

If (ErrAction And ErrAction_ThrowError) = ErrAction_ThrowError Then _
ThrowScriptErrorNoAbort "An error occurred while accessing WMI property: '" &amp; sPropName &amp; "'.", Err

If (ErrAction And ErrAction_Abort) = ErrAction_Abort Then _
Quit()

GetWMIProperty = ""

End If


If (ErrAction And ErrAction_Trace) = ErrAction_Trace Then _
WScript.Echo " + " &amp; sPropName &amp; " :: '" &amp; GetWMIProperty &amp; "'"

End Function


Class Error
Private m_lNumber
Private m_sSource
Private m_sDescription
Private m_sHelpContext
Private m_sHelpFile
Public Sub Save()
m_lNumber = Err.number
m_sSource = Err.Source
m_sDescription = Err.Description
m_sHelpContext = Err.HelpContext
m_sHelpFile = Err.helpfile
End Sub
Public Sub Raise()
Err.Raise m_lNumber, m_sSource, m_sDescription, m_sHelpFile, m_sHelpContext
End Sub
Public Sub Clear()
m_lNumber = 0
m_sSource = ""
m_sDescription = ""
m_sHelpContext = ""
m_sHelpFile = ""
End Sub
Public Default Property Get Number()
Number = m_lNumber
End Property
Public Property Get Source()
Source = m_sSource
End Property
Public Property Get Description()
Description = m_sDescription
End Property
Public Property Get HelpContext()
HelpContext = m_sHelpContext
End Property
Public Property Get HelpFile()
HelpFile = m_sHelpFile
End Property
End Class


Function ThrowScriptErrorNoAbort(ByVal sMessage, ByVal oErr)
'
' ThrowScriptError :: Creates an event and sends it back to the mom server
'
'

Dim sErrDescription, sErrNumber
sErrDescription = oErr.Description
sErrNumber = oErr.Number

End Function

Function ThrowScriptError(Byval sMessage, ByVal oErr)
'
' ThrowScriptError :: Creates an event and sends it back to the mom server
'
'
On Error Resume Next
ThrowScriptErrorNoAbort sMessage, oErr
Quit()
End Function

Function MomCreateObject(ByVal sProgramId)
Dim oError
Set oError = New Error

On Error Resume Next
Set MomCreateObject = CreateObject(sProgramId)
oError.Save
On Error Goto 0

If oError.Number &lt;&gt; 0 Then ThrowScriptError "Unable to create automation object '" &amp; sProgramId &amp; "'", oError
End Function

Function IsValidObject(ByVal oObject)
IsValidObject = False

If IsObject(oObject) Then
If Not oObject Is Nothing Then
IsValidObject = True
End If
End If
End Function

Function GetPerfmonInstance(ByVal sTargetComputer, ByVal sDeviceID, ByVal sIndex)
Dim owObj, owObj2, oWMISet, oWMISet2, sPerfInstance
Dim sTemp
sPerfInstance = ""
Set oWMISet = WMIExecQuery("winmgmts:\\" + sTargetComputer + "\root\cimv2", "associators of {win32_diskdrive='" &amp; sDeviceID &amp;"'} where ResultClass=win32_diskpartition")
For each owObj in oWMISet
sTemp = GetWMIProperty(owObj, "DeviceID", wbemCimtypeUseDefault, ErrAction_Abort)
Set oWMISet2= WMIExecQuery("winmgmts:\\" + sTargetComputer + "\root\cimv2", "associators of {win32_diskpartition='" &amp; sTemp &amp; "'} where ResultClass=win32_logicaldisk")
For each owObj2 in oWMISet2
sTemp = GetWMIProperty(owObj2, "DeviceID", wbemCimtypeUseDefault, ErrAction_Abort)
If sPerfInstance = "" Then
sPerfInstance = sPerfInstance + sTemp
Else
sPerfInstance = sPerfInstance + " " + sTemp
End If
Next
Next
GetPerfmonInstance = sIndex &amp; " " &amp; sPerfInstance
End Function
Function Quit()

WScript.Quit()

End Function



</Script></Contents>
</File>
</Files>
</DataSource>
</MemberModules>
<Composition>
<Node ID="DS"/>
</Composition>
</Composite>
</ModuleImplementation>
<OutputType>System!System.Discovery.Data</OutputType>
</DataSourceModuleType>