A volume group has
failed during a modification operation, such as dynamic capacity
expansion, RAID level migration, etc. This failure code is used
for volume groups containing volumes with different RAID levels.
It is not supported in the current release of the firmware.
What Caused the Problem?
The failure type cannot be determined.
Recovery Steps
1 | Open the Event Log for this storage array by selecting Monitor > Reports > Event Log in the Array Management Window. Look for any recent entries indicating the nature of the failure. | ||||||
2 | Check the storage array for fault indicator lights or other signs of failures.
|
Target | NetAppESeries.StorageArray | ||
Parent Monitor | NetAppESeries.StorageArrayAvailability | ||
Category | Custom | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | NetAppESeries.FailureUnitMonitorType | ||
Remotable | True | ||
Accessibility | Internal | ||
Alert Message |
| ||
RunAs | Default | ||
Comment | Machine generated entity |
<UnitMonitor ID="NetAppESeries.FailureID_0016_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_FAILED_MODIFYING_MULTI_RAID_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateId99B0D1AD9B3B3E41BA6899AC890B63C3" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateId3E5E52E96D3ABD0CB974969E9B3FA844" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>16</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>