Monitor REC_IMPENDING_DRIVE_FAILURE_RISK_LOW (26)

NetAppESeries.FailureID_0026_Monitor (UnitMonitor)

Monitor Description for (26)

Knowledge Base article:

Impending Drive Failure (Unassigned or Standby Hot Spare)

What Caused the Problem?

A drive is reporting internal errors that could cause the drive to fail. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.

 Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touch the components without using a proper ground may damage the equipment.

Important Notes

Recovery Steps

1

Remove the affected drive.

Note: The Service Action Allowed status in the Details area is always NO for this problem because the drive is not yet failed. In this situation, it is acceptable to remove the component even though the Service Action Allowed is NO.

2

Wait 30 seconds, then insert the new drive. Its fault indicator light may be lit for a short time (one minute or less).

3

Click the

Recheck

button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your Technical Support Representative.

Element properties:

TargetNetAppESeries.StorageArray
Parent MonitorNetAppESeries.StorageArrayAvailability
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeNetAppESeries.FailureUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Alert: REC_IMPENDING_DRIVE_FAILURE_RISK_LOW
Alert Value: {0}
RunAsDefault
CommentMachine generated entity

Source Code:

<UnitMonitor ID="NetAppESeries.FailureID_0026_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_IMPENDING_DRIVE_FAILURE_RISK_LOW_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateId54E7257DD100A3FF693343D8A088927B" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateId826041B6BA8E57B7E6A35B2D8EA4D60" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>26</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>