The failure type is Removed Temp Sensor.
What Caused the Problem?
A power-fan canister has been removed from a tray in the storage array. The Recovery Guru Details area provides specific information you will need as you follow the Recovery Steps.
Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.
Important Note
The storage array currently does not have redundant power-fan canisters. Depending on the model of your storage array, a power-fan canister typically contains a power supply, a cooling fan, a temperature sensor, and a battery charging unit. When this canister is removed, redundancy is lost for the storage array's power and cooling systems, and the battery pack(s) associated with the charging unit will not charge until the canister is replaced. The storage array will continue to operate with the remaining power-fan canister. However, failure of the remaining Power-fan canister will result in a loss of access to the storage array. Therefore, make sure you correct this problem as soon as possible.
Recovery Steps
1 |
| ||||||
2 | Reinsert the power-fan canister securely back into place. | ||||||
3 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your technical support representative. |
Target | NetAppESeries.StorageArray | ||
Parent Monitor | NetAppESeries.StorageArrayAvailability | ||
Category | Custom | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | NetAppESeries.FailureUnitMonitorType | ||
Remotable | True | ||
Accessibility | Internal | ||
Alert Message |
| ||
RunAs | Default | ||
Comment | Machine generated entity |
<UnitMonitor ID="NetAppESeries.FailureID_0086_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_REMOVED_TEMP_SENSOR_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateId8A15E73A1442188599911BB1E5D508C0" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateIdE6D68C12A21A365D9C5DD65BD7E00567" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>86</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>