Monitor REC_REMOVED_TEMP_SENSOR (86)

NetAppESeries.FailureID_0086_Monitor (UnitMonitor)

The failure type is Removed Temp Sensor.

Knowledge Base article:

Removed Power-Fan Canister

What Caused the Problem?

A power-fan canister has been removed from a tray in the storage array. The Recovery Guru Details area provides specific information you will need as you follow the Recovery Steps.

 Caution: Electrostatic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.

Important Note

The storage array currently does not have redundant power-fan canisters. Depending on the model of your storage array, a power-fan canister typically contains a power supply, a cooling fan, a temperature sensor, and a battery charging unit. When this canister is removed, redundancy is lost for the storage array's power and cooling systems, and the battery pack(s) associated with the charging unit will not charge until the canister is replaced. The storage array will continue to operate with the remaining power-fan canister. However, failure of the remaining Power-fan canister will result in a loss of access to the storage array. Therefore, make sure you correct this problem as soon as possible.

Recovery Steps

1

If...

Then...

You removed the power-fan canister because you were instructed to do so from the Recovery Steps for a Failed Power-fan canister

Disregard this problem in the Summary area, as the problem will no longer appear in the Summary area when you complete the Recovery Steps for the Failed Power-Fan Canister problem.

You removed the power-fan canister, but it is not failed

Go to step 2.

2

Reinsert the power-fan canister securely back into place.

3

Click the

Recheck

button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your technical support representative.

Element properties:

TargetNetAppESeries.StorageArray
Parent MonitorNetAppESeries.StorageArrayAvailability
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeNetAppESeries.FailureUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Alert: REC_REMOVED_TEMP_SENSOR
The failure type is Removed Temp Sensor. Alert Value: {0}
RunAsDefault
CommentMachine generated entity

Source Code:

<UnitMonitor ID="NetAppESeries.FailureID_0086_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_REMOVED_TEMP_SENSOR_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateId8A15E73A1442188599911BB1E5D508C0" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateIdE6D68C12A21A365D9C5DD65BD7E00567" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>86</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>