Monitor REC_NATIVE_VG_FOREIGN_DRIVE_MUTUAL_REF (215)

NetAppESeries.FailureID_0215_Monitor (UnitMonitor)

A volume group in the partial state along with its missing drive are present in the same storage array. Their respective metadata are in agreement with respect to volume group membership; however, the storage array considers the volume group as native and the drive as foreign.

Knowledge Base article:

Native Volume Group And Foreign Drive Refer to Each Other

What Caused the Problem?

A Partially Complete Volume Group considers a foreign drive to be a member of the volume group and the foreign drive also considers itself a member of the Partially Complete Volume Group. A foreign drive is a drive that has been exported from this storage array or not yet completely imported into the storage array. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.

Caution: Electronic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.

Important Notes

Recovery Steps

1

Refer to the Details area to find which drive slot is reporting the foreign drive.

2

Remove the foreign drive.

The affected volume group transitions to a Partially Complete Volume Group state because it has a Missing drive instead of a reference to a Foreign drive.

3

Important

: Read all of the following steps thoroughly or click the

Save As

button before taking action, because you will lose access to these Recovery Steps once you click

Recheck

a

Click

Recheck

to rerun the Recovery Guru.

b

Select the "Partially Complete Volume Group" problem in the Summary area.

c

Complete the Recovery Steps for this problem to transition the volume group to an Optimal state.

Note: Choose the option in the Recovery Steps that explains how to replace the missing drive using the Replace Drives dialog.

Element properties:

TargetNetAppESeries.StorageArray
Parent MonitorNetAppESeries.StorageArrayAvailability
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeNetAppESeries.FailureUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Alert: REC_NATIVE_VG_FOREIGN_DRIVE_MUTUAL_REF
A volume group in the partial state along with its missing drive are present in the same storage array. Their respective metadata are in agreement with respect to volume group membership; however, the storage array considers the volume group as native and the drive as foreign. Alert Value: {0}
RunAsDefault
CommentMachine generated entity

Source Code:

<UnitMonitor ID="NetAppESeries.FailureID_0215_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_NATIVE_VG_FOREIGN_DRIVE_MUTUAL_REF_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateIdD801971C6F81FAA3D2E2A3B34E695F51" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateIdB3FCA0EE1A22CC31AEBF5FC4B74C928A" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>215</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>