Monitor REC_RAID6_NOT_COMPLIANT_SVM (359)

NetAppESeries.FailureID_0359_Monitor (UnitMonitor)

A RAID 6 SAFE key has been imported to the storage array on a set of foreign drives, and the storage array is now out of compliance; or the RAID 6 SAFE key has been removed, and there are still RAID 6 volume groups present in the storage array (i.e., "not within limits"). This enumeration value is unique to firmware that supports virtualization.

Knowledge Base article:

Undocumented error: REC_RAID6_NOT_COMPLIANT_SVM

There is no documentation for the REC_RAID6_NOT_COMPLIANT_SVM alert

Element properties:

TargetNetAppESeries.StorageArray
Parent MonitorNetAppESeries.StorageArrayAvailability
CategoryCustom
EnabledTrue
Alert GenerateTrue
Alert SeverityError
Alert PriorityNormal
Alert Auto ResolveTrue
Monitor TypeNetAppESeries.FailureUnitMonitorType
RemotableTrue
AccessibilityInternal
Alert Message
Alert: REC_RAID6_NOT_COMPLIANT_SVM
A RAID 6 SAFE key has been imported to the storage array on a set of foreign drives, and the storage array is now out of compliance; or the RAID 6 SAFE key has been removed, and there are still RAID 6 volume groups present in the storage array (i.e., "not within limits"). This enumeration value is unique to firmware that supports virtualization. Alert Value: {0}
RunAsDefault
CommentMachine generated entity

Source Code:

<UnitMonitor ID="NetAppESeries.FailureID_0359_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_RAID6_NOT_COMPLIANT_SVM_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateId67400ADFC5B0316AF86A67F7E666BB3E" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateId32254AE4B7AAD6F74CB8D940CCC085F6" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>359</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>