The drive has an incompatible Protection Information type.
What Caused the Problem?
A Protection Information-formatted (PI) drive was inserted into the storage array. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.
Important Notes
PI drives are incompatible with the storage array and are locked out. The Details area identifies whether the PI drive is type 1 or type 2.
A critical MEL event is generated from each PI-formatted.
You can replace the drive while the storage array is receiving I/O.
Recovery Steps
1 | Review the Recovery Guru Details area to identify the affected PI drive. |
2 | Remove the drive. |
3 | Insert a non-PI-formatted drive into the storage array. |
4 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, recheck your cabling and, if necessary, contact your Technical Support Representative. |
Target | NetAppESeries.StorageArray | ||
Parent Monitor | NetAppESeries.StorageArrayAvailability | ||
Category | Custom | ||
Enabled | True | ||
Alert Generate | True | ||
Alert Severity | Error | ||
Alert Priority | Normal | ||
Alert Auto Resolve | True | ||
Monitor Type | NetAppESeries.FailureUnitMonitorType | ||
Remotable | True | ||
Accessibility | Internal | ||
Alert Message |
| ||
RunAs | Default | ||
Comment | Machine generated entity |
<UnitMonitor ID="NetAppESeries.FailureID_0392_Monitor" Accessibility="Internal" Enabled="true" Target="NetAppESeries.StorageArray" ParentMonitorID="NetAppESeries.StorageArrayAvailability" Remotable="true" Priority="Normal" TypeID="NetAppESeries.FailureUnitMonitorType" ConfirmDelivery="true" Comment="Machine generated entity">
<Category>Custom</Category>
<AlertSettings AlertMessage="NetAppESeries.REC_DRIVE_INCOMPATIBLE_PI_TYPE_AlertMessageResourceID">
<AlertOnState>Error</AlertOnState>
<AutoResolve>true</AutoResolve>
<AlertPriority>Normal</AlertPriority>
<AlertSeverity>Error</AlertSeverity>
<AlertParameters>
<AlertParameter1>$Data/Context/Property[@Name='FailureDescription']$</AlertParameter1>
</AlertParameters>
</AlertSettings>
<OperationalStates>
<OperationalState ID="NetAppESeries.StateIdFA275F2D3E826EBF9F590629293AEE8D" MonitorTypeStateID="NoIssue" HealthState="Success"/>
<OperationalState ID="NetAppESeries.StateId1BEDBD9CB2F1C8D3DCC951EA2387455B" MonitorTypeStateID="IssueFound" HealthState="Error"/>
</OperationalStates>
<Configuration>
<FailureID>392</FailureID>
<IntervalSeconds>59</IntervalSeconds>
<TimeoutSeconds>300</TimeoutSeconds>
<Trace>0</Trace>
</Configuration>
</UnitMonitor>