ConfigMgr 2007 Status: Site VSS Writer aborted the backup

SMSv4_Status__Site_VSS_Writer_aborted_the_backup_1_Rule (Rule)

Element properties:

TargetMicrosoft.SystemCenter.ConfigurationManager.2007.Microsoft_SMSv4_Site_Database_Servers_Installation
CategoryEventCollection
EnabledTrue
Alert GenerateFalse
RemotableTrue
CommentMom2005ID='{FF16954E-C37B-4C53-AFA6-75C1ED1440B0}';MOM2005ComputerGroupID={15348338-2E39-4B34-9DFF-4719AE7F1CCE}

Member Modules:

ID Module Type TypeId RunAs 
_F320DA51_13BF_11D3_B2CD_00A0C92A28B4_ DataSource System.Mom.BackwardCompatibility.FilteredEvent.DataProvider Default
GenerateAlert WriteAction System.Mom.BackwardCompatibility.AlertResponse Default

Source Code:

<Rule ID="SMSv4_Status__Site_VSS_Writer_aborted_the_backup_1_Rule" Target="Microsoft.SystemCenter.ConfigurationManager.2007.Microsoft_SMSv4_Site_Database_Servers_Installation" Enabled="true" ConfirmDelivery="false" Comment="Mom2005ID='{FF16954E-C37B-4C53-AFA6-75C1ED1440B0}';MOM2005ComputerGroupID={15348338-2E39-4B34-9DFF-4719AE7F1CCE}">
<Category>EventCollection</Category>
<DataSources>
<DataSource ID="_F320DA51_13BF_11D3_B2CD_00A0C92A28B4_" Comment="{F320DA51-13BF-11D3-B2CD-00A0C92A28B4}" TypeID="MomBackwardCompatibility!System.Mom.BackwardCompatibility.FilteredEvent.DataProvider">
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="Integer">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>6832</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>ConfigMgr 2007 Monitor SMS Status Messages</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="System.Mom.BackwardCompatibility.AlertResponse">
<GenerateAlert>true</GenerateAlert>
<Owner/>
<Description>
$Data/Params/Param[1]$
- ConfigMgr 2007 Status: Site VSS Writer aborted the backup.


$Data/EventDescription$


The status message contains message properties

Machine Name:
$Data/Params/Param[1]$

Module Name:
$Data/Params/Param[2]$

Component:
$Data/Params/Param[3]$

Message ID:
$Data/Params/Param[4]$

Win32 Error:
$Data/Params/Param[5]$

Top Level Site Code:
$Data/Params/Param[6]$

Database Record ID:
$Data/Params/Param[7]$
</Description>
<AlertLevel>30</AlertLevel>
<ResolutionState/>
<Source>
$Data/PublisherName$
</Source>
<Name>ConfigMgr 2007 Status: Site VSS Writer aborted the backup</Name>
<InvokerType>0</InvokerType>
</WriteAction>
</WriteActions>
</Rule>