| DisplayName | Description | ID | Target | Category | Enabled | Instance Name | Counter Name | Frequency | Event_ID | Event Source | Alert Generate | Alert Severity | Alert Priority | Remotable | Event Log |
| upsAdvInputLineVoltage | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvInputLineVoltage
Name
upsAdvInputLineVoltage
Oid
1.3.6.1.4.1.318.1.1.1.3.2.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsInput . upsAdvInput . upsAdvInputLineVoltage
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current utility line voltage in VAC. | MomUIGeneratedRule07f9fe0749334f0292daea8591a0470d | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvBatteryCapacity | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvBatteryCapacity
Name
upsAdvBatteryCapacity
Oid
1.3.6.1.4.1.318.1.1.1.2.2.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryCapacity
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The remaining battery capacity expressed in percent of full capacity. | MomUIGeneratedRule1b9a0e513d6c44ea97c2a416f675b9cb | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvOutputLoad | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvOutputLoad
Name
upsAdvOutputLoad
Oid
1.3.6.1.4.1.318.1.1.1.4.2.3.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputLoad
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current UPS load expressed in percent of rated capacity. | MomUIGeneratedRule2d09167ff37a46e3865a15199244b5cf | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsBasicBatteryStatus | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsBasicBatteryStatus
Name
upsBasicBatteryStatus
Oid
1.3.6.1.4.1.318.1.1.1.2.1.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsBasicBattery . upsBasicBatteryStatus
Base-Type
integer
Known-Values
unknown (1) batteryNormal (2) batteryLow (3)
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime. | MomUIGeneratedRule31a30b93bd594a2392756f3cb6594fc9 | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvBatteryRunTimeRemaining | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvBatteryRunTimeRemaining
Name
upsAdvBatteryRunTimeRemaining
Oid
1.3.6.1.4.1.318.1.1.1.2.2.3.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryRunTimeRemaining
Type
TimeTicks
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The UPS battery run time remaining before battery exhaustion. | MomUIGeneratedRule4addd78055e9417a99de96c4757ead22 | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvOutputCurrent | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvOutputCurrent
Name
upsAdvOutputCurrent
Oid
1.3.6.1.4.1.318.1.1.1.4.2.4.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputCurrent
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current in amperes drawn by the load on the UPS. | MomUIGeneratedRule5afcd98df6554058b3190d8862338e2c | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvOutputFrequency | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvOutputFrequency
Name
upsAdvOutputFrequency
Oid
1.3.6.1.4.1.318.1.1.1.4.2.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputFrequency
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current output frequency of the UPS system in Hz. | MomUIGeneratedRule5db9c9c2fe0f45a8be25f649dc32dab7 | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvInputFrequency | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvInputFrequency
Name
upsAdvInputFrequency
Oid
1.3.6.1.4.1.318.1.1.1.3.2.4.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsInput . upsAdvInput . upsAdvInputFrequency
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current input frequency to the UPS system in Hz. | MomUIGeneratedRule7069bd8d26e34994b4a2d168d782e28d | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvBatteryTemperature | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvBatteryTemperature
Name
upsAdvBatteryTemperature
Oid
1.3.6.1.4.1.318.1.1.1.2.2.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryTemperature
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The current internal UPS temperature expressed in Celsius. | MomUIGeneratedRule865bfdd4dad841f3b164c76793a50357 | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsAdvOutputVoltage | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsAdvOutputVoltage
Name
upsAdvOutputVoltage
Oid
1.3.6.1.4.1.318.1.1.1.4.2.1.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputVoltage
Type
Gauge
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The output voltage of the UPS system in VAC. | MomUIGeneratedRule96b04072e6554cc282ed6c26f991f14c | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |
| upsBasicBatteryTimeOnBattery | Date: 2012-03-21
Author: Justin Bennett
Web: http://justin-bennett-msjc.blogspot.com/
Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds.
References:
http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/
http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx
POWERNET-MIB :: upsBasicBatteryTimeOnBattery
Name
upsBasicBatteryTimeOnBattery
Oid
1.3.6.1.4.1.318.1.1.1.2.1.2.0
Path
iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsBasicBattery . upsBasicBatteryTimeOnBattery
Type
TimeTicks
Value-Ranges
0 to 4294967295
Access
read-only
Status
mandatory
Description
--------------------------------------------------------------------------------
The elapsed time since the UPS has switched to battery power. | MomUIGeneratedRulebdd069c9d0ff47eb854bd0952a1638d0 | Custom.JB.APC.Management.Pack.SNMPDevice | Custom | True | | | 0 | 0 | | False | | | True | |