MomUIGeneratedRule07f9fe0749334f0292daea8591a0470dupsAdvInputLineVoltageDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvInputLineVoltage Name upsAdvInputLineVoltage Oid 1.3.6.1.4.1.318.1.1.1.3.2.1.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsInput . upsAdvInput . upsAdvInputLineVoltage Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The current utility line voltage in VAC.MomUIGeneratedRule07f9fe0749334f0292daea8591a0470dCustom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule1b9a0e513d6c44ea97c2a416f675b9cbupsAdvBatteryCapacityDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvBatteryCapacity Name upsAdvBatteryCapacity Oid 1.3.6.1.4.1.318.1.1.1.2.2.1.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryCapacity Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The remaining battery capacity expressed in percent of full capacity.MomUIGeneratedRule1b9a0e513d6c44ea97c2a416f675b9cbCustom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule2d09167ff37a46e3865a15199244b5cfupsAdvOutputLoadDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvOutputLoad Name upsAdvOutputLoad Oid 1.3.6.1.4.1.318.1.1.1.4.2.3.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputLoad Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The current UPS load expressed in percent of rated capacity.MomUIGeneratedRule2d09167ff37a46e3865a15199244b5cfCustom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule31a30b93bd594a2392756f3cb6594fc9upsBasicBatteryStatusDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsBasicBatteryStatus Name upsBasicBatteryStatus Oid 1.3.6.1.4.1.318.1.1.1.2.1.1.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsBasicBattery . upsBasicBatteryStatus Base-Type integer Known-Values unknown (1) batteryNormal (2) batteryLow (3) Access read-only Status mandatory Description -------------------------------------------------------------------------------- The status of the UPS batteries. A batteryLow(3) value indicates the UPS will be unable to sustain the current load, and its services will be lost if power is not restored. The amount of run time in reserve at the time of low battery can be configured by the upsAdvConfigLowBatteryRunTime.MomUIGeneratedRule31a30b93bd594a2392756f3cb6594fc9Custom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule4addd78055e9417a99de96c4757ead22upsAdvBatteryRunTimeRemainingDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvBatteryRunTimeRemaining Name upsAdvBatteryRunTimeRemaining Oid 1.3.6.1.4.1.318.1.1.1.2.2.3.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryRunTimeRemaining Type TimeTicks Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The UPS battery run time remaining before battery exhaustion.MomUIGeneratedRule4addd78055e9417a99de96c4757ead22Custom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule5afcd98df6554058b3190d8862338e2cupsAdvOutputCurrentDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvOutputCurrent Name upsAdvOutputCurrent Oid 1.3.6.1.4.1.318.1.1.1.4.2.4.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputCurrent Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The current in amperes drawn by the load on the UPS.MomUIGeneratedRule5afcd98df6554058b3190d8862338e2cCustom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule5db9c9c2fe0f45a8be25f649dc32dab7upsAdvOutputFrequencyDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvOutputFrequency Name upsAdvOutputFrequency Oid 1.3.6.1.4.1.318.1.1.1.4.2.2.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputFrequency Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The current output frequency of the UPS system in Hz.MomUIGeneratedRule5db9c9c2fe0f45a8be25f649dc32dab7Custom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule7069bd8d26e34994b4a2d168d782e28dupsAdvInputFrequencyDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvInputFrequency Name upsAdvInputFrequency Oid 1.3.6.1.4.1.318.1.1.1.3.2.4.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsInput . upsAdvInput . upsAdvInputFrequency Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The current input frequency to the UPS system in Hz.MomUIGeneratedRule7069bd8d26e34994b4a2d168d782e28dCustom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule865bfdd4dad841f3b164c76793a50357upsAdvBatteryTemperatureDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvBatteryTemperature Name upsAdvBatteryTemperature Oid 1.3.6.1.4.1.318.1.1.1.2.2.2.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsAdvBattery . upsAdvBatteryTemperature Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The current internal UPS temperature expressed in Celsius.MomUIGeneratedRule865bfdd4dad841f3b164c76793a50357Custom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRule96b04072e6554cc282ed6c26f991f14cupsAdvOutputVoltageDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsAdvOutputVoltage Name upsAdvOutputVoltage Oid 1.3.6.1.4.1.318.1.1.1.4.2.1.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsOutput . upsAdvOutput . upsAdvOutputVoltage Type Gauge Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The output voltage of the UPS system in VAC.MomUIGeneratedRule96b04072e6554cc282ed6c26f991f14cCustom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue
MomUIGeneratedRulebdd069c9d0ff47eb854bd0952a1638d0upsBasicBatteryTimeOnBatteryDate: 2012-03-21 Author: Justin Bennett Web: http://justin-bennett-msjc.blogspot.com/ Description: SCOM Rule that polls and logs APC UPS Units using Ralph Burri's custom snmp provider library. The OID's for the APC UPS units where looked up from SolarWinds. References: http://rburri.wordpress.com/2008/04/29/snmp-discovery-provider-for-opsmgr-2007/ http://support.ipmonitor.com/mibs/POWERNET-MIB/info.aspx POWERNET-MIB :: upsBasicBatteryTimeOnBattery Name upsBasicBatteryTimeOnBattery Oid 1.3.6.1.4.1.318.1.1.1.2.1.2.0 Path iso . org . dod . internet . private . enterprises . apc . products . hardware . ups . upsBattery . upsBasicBattery . upsBasicBatteryTimeOnBattery Type TimeTicks Value-Ranges 0 to 4294967295 Access read-only Status mandatory Description -------------------------------------------------------------------------------- The elapsed time since the UPS has switched to battery power.MomUIGeneratedRulebdd069c9d0ff47eb854bd0952a1638d0Custom.JB.APC.Management.Pack.SNMPDeviceCustomTrue00FalseTrue