| DisplayName | Description | ID | Target | Category | Enabled | Instance Name | Counter Name | Frequency | Event_ID | Event Source | Alert Generate | Alert Severity | Alert Priority | Remotable | Event Log |
| HPE Windows (WMI) Memory degraded. | The Advanced Memory Protection (AMP) system is operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail. | HewlettPackard.Servers.ProLiant.WMI.Advanced_Memory_Protection_degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIMemory | Alert | True | | | 0 | 3 | HP Memory | True | Warning | High | True | System |
| HPE Windows (WMI) ASR reboot occurred. | The system has rebooted from a Automatic Server Recovery (ASR) event. | HewlettPackard.Servers.ProLiant.WMI.ASR_reboot_occurred_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessors | Alert | True | | | 0 | 1 | HP System | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Controller battery failed. | A Smart Array controller battery status changed to Failed. | HewlettPackard.Servers.ProLiant.WMI.Controller_battery_status_Failed_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 8 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array controller battery degraded. | A Smart Array controller Battery status has changed to Not Fully Charged. | HewlettPackard.Servers.ProLiant.WMI.Controller_Battery_Status_set_to_Not_fully_Charged_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 7 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array controller degraded. | A Smart Array controller redundancy state has changed from Standby to Active. | HewlettPackard.Servers.ProLiant.WMI.Controller_redundancy_state_set_to_Active_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array controller failed. | A Smart Array controller status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.Controller_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 2 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Fan degraded. | Cooling redundancy has been lost. | HewlettPackard.Servers.ProLiant.WMI.Cooling_redundancy_lost_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMICooling | Alert | True | | | 0 | 6 | HP Sensor | True | Warning | High | True | System |
| HPE Windows (WMI) Enable x2APIC mode for optimal system performance. | The system is not configured for optimal performance as its x2APIC mode is currently disabled. Enabling x2APIC allows better performance in the delivery and handling of interrupts, both in hardware and software, thus improving overall system performance. | HewlettPackard.Servers.ProLiant.WMI.Enable_x2APIC_mode_for_optimal_system_performance_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 8010 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) NIC teaming degraded. | An Ethernet team's redundancy has decreased. A team member has changed to failed or degraded state. | HewlettPackard.Servers.ProLiant.WMI.Ethernet_teams_redundancy_decreased_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworks | Alert | True | | | 0 | 4 | HP Ethernet | True | Warning | High | True | System |
| HPE Windows (WMI) NIC teaming failed. | An Ethernet team's redundancy status changed to Redundancy Lost. All members of an Ethernet team, except one, are failed. | HewlettPackard.Servers.ProLiant.WMI.Ethernet_team_lost_redundancy_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworks | Alert | True | | | 0 | 5 | HP Ethernet | True | Error | High | True | System |
| HPE Windows (WMI) NIC team member dropped. | A team member was dropped from the team via the HPE Network Configuration Utility (NCU). This is an optional indication that can be disabled via the Ethernet Event Provider settings. | HewlettPackard.Servers.ProLiant.WMI.Ethernet_team_member_dropped_from_team_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworks | Alert | True | | | 0 | 8 | HP Ethernet | True | Warning | High | True | System |
| HPE Windows (WMI) Fan degraded. | A fan has failed. | HewlettPackard.Servers.ProLiant.WMI.Fan_Degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMICooling | Alert | True | | | 0 | 9 | HP Sensor | True | Warning | High | True | System |
| HPE Windows (WMI) Fan failed. | A fan has failed. | HewlettPackard.Servers.ProLiant.WMI.Fan_failed_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMICooling | Alert | True | | | 0 | 3 | HP Sensor | True | Error | High | True | System |
| HPE Windows (WMI) FC Storage system failed. |
A fibre channel port has changed to a failed status.Replace the fibre channel HBA card. | HewlettPackard.Servers.ProLiant.WMI.FC_System_failed_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 7 | HP Fibre Channel | True | Error | High | True | System |
| HPE Windows (WMI) FC storage system link down. | A fibre channel HBA port has changed to a state of link down.Check the FC cabling to this port. Reinsert the FC GBIC if it has been unplugged. Replace FC cabling or the FC GBIC if failure continues. | HewlettPackard.Servers.ProLiant.WMI.FC_System_link_down_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 6 | HP Fibre Channel | True | Error | High | True | System |
| HPE Windows (WMI) SAS controller failed. | A SAS/SATA HBA status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.HBA_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 2 | HP SAS | True | Error | High | True | System |
| HPE Windows (WMI) HPE Power Regulator mode is not in an optimal setting | The HPE Power Regulator mode should be set to OS Control mode | HewlettPackard.Servers.ProLiant.WMI.HP_Power_Regulator_mode_is_not_in_an_optimal_setting_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 8014 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) Interrupt redirection mode should be set to physical destination mode | When x2APIC is enabled on DL980 system, the interrupt redirection mode should be set to physical destination mode, which is not the default mode. | HewlettPackard.Servers.ProLiant.WMI.Interrupt_redirection_mode_should_be_set_to_physical_destination_mode_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 8016 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) SAS logical drive degraded. | A logical drive is in a degraded state. Device is still servicing I/O, but redundancy may be degraded or lost. | HewlettPackard.Servers.ProLiant.WMI.Logical_drive_degraded_state_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 103 | HP SAS | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array logical drive degraded - Multipath. | A logical drive is in a degraded state. Multipath support is Lost. Either cable is removed or not configured. | HewlettPackard.Servers.ProLiant.WMI.Logical_drive_in_degraded_multipath_state_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 104 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array logical drive degraded. | A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost. | HewlettPackard.Servers.ProLiant.WMI.Logical_drive_in_degraded_state_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 103 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) logical processor configuration should be changed for optimal performance. | The system does not have the logical processor configuration set for optimal performance. Either some logical processors are disabled, or processor cores are not evenly enabled across sockets. | HewlettPackard.Servers.ProLiant.WMI.logical_processor_configuration_should_be_changed_for_optimal_performance_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 0 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) Management Processor reset failed | The Management Processor has not reset successfully and may not be operational. | HewlettPackard.Servers.ProLiant.WMI.Management_Processor_Reset_Failed_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIManagementProcessors | Alert | True | | | 0 | 3 | HP MgmtProc | True | Error | High | True | System |
| HPE Windows (WMI) Memory board failed. | A memory board has an error. | HewlettPackard.Servers.ProLiant.WMI.Memory_board_error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIMemory | Alert | True | | | 0 | 2 | HP Memory | True | Error | High | True | System |
| HPE Windows (WMI) Memory failed. | A memory module has failed or is predicted to fail. | HewlettPackard.Servers.ProLiant.WMI.Memory_module_has_failed_or_is_predicted_to_fail_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIMemory | Alert | True | | | 0 | 1 | HP Memory | True | Error | High | True | System |
| HPE Windows (WMI) Network interface failed. | A network interface has failed. An Ethernet adapter's status changed from OK to Error, or an Ethernet team's status changed to Error from another state. | HewlettPackard.Servers.ProLiant.WMI.Network_interface_lost_connectivity_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworks | Alert | True | | | 0 | 2 | HP Ethernet | True | Error | High | True | System |
| HPE Windows (WMI) Network interface degraded. | A network interface is no longer available. An Ethernet adapter was removed or an Ethernet team or VLAN was removed via the HPE Network Configuration Utility (NCU). | HewlettPackard.Servers.ProLiant.WMI.Network_interface_no_longer_available_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerNetworks | Alert | True | | | 0 | 12 | HP Ethernet | True | Warning | High | True | System |
| HPE Windows (WMI) SCSI physical drive failed. | A SCSI physical drive has a status of Error. | HewlettPackard.Servers.ProLiant.WMI.Physical_drive_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP SCSI | True | Error | High | True | System |
| HPE Windows (WMI) SAS physical drive predictive failure. | A physical drive status has changed to Predictive Failure. | HewlettPackard.Servers.ProLiant.WMI.Physical_drive_predictive_failure_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP SAS | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array physical drive secure erase. | A Physical Drive is Currently Offline but operational, Secure Erase is in Progress. | HewlettPackard.Servers.ProLiant.WMI.Physical_drive_secure_erase_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 205 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array physical drive status degraded. | A physical drive was not authenticated and could not be valideted to be a genuine HPE hard drive. | HewlettPackard.Servers.ProLiant.WMI.Physical_drive_status_Degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 312 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array physical drive predictive failure. | A physical drive status has changed to Predictive Failure. | HewlettPackard.Servers.ProLiant.WMI.Physical_drive_status_Predictive_Failure_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) POST errors occurred. | Power-On-Self-Test (POST) errors occurred during the last system startup. | HewlettPackard.Servers.ProLiant.WMI.POST_errors_occurred_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessors | Alert | True | | | 0 | 1001 | HP System | True | Warning | High | True | System |
| HPE Windows (WMI) Power sub-system degraded. | Power redundancy has been lost. | HewlettPackard.Servers.ProLiant.WMI.Power_redundancy_lost_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIPowerSupplies | Alert | True | | | 0 | 1006 | HP Sensor | True | Warning | High | True | System |
| HPE Windows (WMI) Power supply failed. | A power supply has failed. | HewlettPackard.Servers.ProLiant.WMI.Power_supply_failed_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIPowerSupplies | Alert | True | | | 0 | 1003 | HP Sensor | True | Error | High | True | System |
| HPE Windows (WMI) Power supply input power lost. | A power supply has failed input power lost. | HewlettPackard.Servers.ProLiant.WMI.Power_supply_input_power_lost_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIPowerSupplies | Alert | True | | | 0 | 1009 | HP Sensor | True | Error | High | True | System |
| HPE Windows (WMI) Processor degraded. | A processor has been disabled by ROM Based Setup (RBSU). | HewlettPackard.Servers.ProLiant.WMI.Processor_deconfigured_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessors | Alert | True | | | 0 | 2 | HP Processor | True | Error | High | True | System |
| HPE Windows (WMI) Processor failed. | A processor has failed. | HewlettPackard.Servers.ProLiant.WMI.Processor_failed_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessors | Alert | True | | | 0 | 1 | HP Processor | True | Error | High | True | System |
| HPE Windows (WMI) SAS storage system fan degraded. | A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans. | HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 305 | HP SAS | True | Warning | High | True | System |
| HPE Windows (WMI) SAS storage system fan failed. | A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. | HewlettPackard.Servers.ProLiant.WMI.SAS_Fan_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 306 | HP SAS | True | Error | High | True | System |
| HPE Windows (WMI) SAS logical drive failed. | A logical drive status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.SAS_Logical_drive_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 102 | HP SAS | True | Error | High | True | System |
| HPE Windows (WMI) SAS physical drive status degraded. | A physical drive was not able to be authenticated and could not be validated to be a genuine HPE hard drive. | HewlettPackard.Servers.ProLiant.WMI.SAS_Physical_drive_status_degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 312 | HP SAS | True | Warning | High | True | System |
| HPE Windows (WMI) SAS physical drive failed. | A physical drive status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.SAS_Physical_drive_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 202 | HP SAS | True | Error | High | True | System |
| HPE Windows (WMI) SAS storage system power supply degraded. | A Storage Enclosure Power Subsystem status has changed to non-redundant. | HewlettPackard.Servers.ProLiant.WMI.SAS_Power_Supply_status_Non_Redundant_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP SAS | True | Warning | High | True | System |
| HPE Windows (WMI) SAS storage system temperature failed. | A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. | HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Critical_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 309 | HP SAS | True | Error | High | True | System |
| HPE Windows (WMI) SAS storage system temperature degraded. | A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. | HewlettPackard.Servers.ProLiant.WMI.SAS_Temperature_sensor_status_Warning_Condition_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 308 | HP SAS | True | Warning | High | True | System |
| HPE Windows (WMI) SATA physical drive degraded. | A physical drive is degraded. | HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 604 | HP SATA | True | Warning | High | True | System |
| HPE Windows (WMI) SATA physical drive failed. | A physical drive status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP SATA | True | Error | High | True | System |
| HPE Windows (WMI) SATA physical drive predictive failure. | A physical drive status has changed to Predictive Failure. | HewlettPackard.Servers.ProLiant.WMI.SATA_Physical_drive_status_Predictive_Failure_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 605 | HP SATA | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array controller ASIC encryption self test failed status. | A Smart Array Controller ASIC encryption self test status has changed to Failed because of ASIC encryption self tests failure. | HewlettPackard.Servers.ProLiant.WMI.SA_controller_ASIC_encryption_self_test_status_failed | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 14 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array controller cache status not configured. | A Smart Array Controller Cache status has changed to not configured. This may be caused by a configuration change. | HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_not_configured | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 12 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array controller cache status degraded. | A Smart Array Controller Cache status has changed to Degraded. | HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_status_degraded | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 10 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array controller cache status failed. | A Smart Array Controller Cache status has changed to Failed. The controller has detected a problem with the cache and has failed the cache. | HewlettPackard.Servers.ProLiant.WMI.SA_controller_cache_status_failed | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 11 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array controller encryption CSP NVRAM status detection failed. | A Smart Array Controller encryption CSP NVRAM status has changed to Failed because of CSP NVRAM detection failure. | HewlettPackard.Servers.ProLiant.WMI.SA_controller_encryption_CSP_NVRAM_status_detection_failed | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 16 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array storage system fan degraded. | A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there may a problem with one or more of the fans. | HewlettPackard.Servers.ProLiant.WMI.SA_Fan_status_Degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 305 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array storage system fan failed. | A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. | HewlettPackard.Servers.ProLiant.WMI.SA_Fan_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 306 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive degraded - Expanding. | A logical drive status has changed to Expanding. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Expanding_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 105 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive in degraded state - Not yet available. | A logical drive status has changed to Not Yet Available. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Not_yet_available | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 107 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive in degraded state - Queued for Expansion. | A logical drive status has changed to Queued for Expansion. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_Queued_for_Expansion | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 106 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive in degraded state - RPI in progress. | A logical drive status has changed to Rapid Parity Initialization in progress. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_RPI_in_progress | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 111 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive in degraded state - RPI Queued. | A logical drive status has changed to Rapid Parity Initialization Queued. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_in_degraded_state_RPI_Queued | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 112 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive status Degraded - New Logical Drive Key Rekey In Progress. | A logical drive status has changed to New Logical Drive Key Rekey In Progress. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_Degraded_New_Logical_Drive_Key_Rekey_In_Progress | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 113 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive status Degraded - transforming from Unencrypted to Encrypted. | A logical drive status has changed to transforming from Unencrypted to Encrypted. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_Degraded_transforming_from_Unencrypted_to_Encrypted | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 109 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive failed. | A logical drive status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 102 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive status error - No Access - Encrypted with Controller Encryption Not Enabled. | A logical drive status has changed to No Access - Encrypted with Controller Encryption Not Enabled. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_No_Access_Encrypted_with_Controller_Encryption_Not_Enabled | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 110 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array Logical drive status error - No Access - Encrypted with No Controller Key. | A logical drive status has changed to No Access- Encrypted with No Controller Key. | HewlettPackard.Servers.ProLiant.WMI.SA_Logical_drive_status_No_Access_Encrypted_with_No_Controller_Key | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 108 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array physical drive failed. | A physical drive status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.SA_Physical_drive_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 202 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array storage system power supply degraded. | A Storage Enclosure Power Subsystem status has changed to non-redundant. | HewlettPackard.Servers.ProLiant.WMI.SA_Power_Supply_status_Non_Redundant_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) Smart Array storage system temperature failed. | A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. | HewlettPackard.Servers.ProLiant.WMI.SA_Temperature_sensor_status_Critical_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 309 | HP Smart Array | True | Error | High | True | System |
| HPE Windows (WMI) Smart Array storage system temperature degraded. | A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. | HewlettPackard.Servers.ProLiant.WMI.SA_Temperature_sensor_status_Warning_Condition_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 308 | HP Smart Array | True | Warning | High | True | System |
| HPE Windows (WMI) SCSI storage system fan degraded. | A fan has failed, but there are enough fans in the fan subsystem to keep the enclosure cool. | HewlettPackard.Servers.ProLiant.WMI.SCSI_Fan_status_Degraded_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 305 | HP SCSI | True | Warning | High | True | System |
| HPE Windows (WMI) SCSI storage system fan failed. | A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool. | HewlettPackard.Servers.ProLiant.WMI.SCSI_Fan_status_Error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 306 | HP SCSI | True | Error | High | True | System |
| HPE Windows (WMI) SCSI controller failed. | A SCSI HBA status has changed to Error. | HewlettPackard.Servers.ProLiant.WMI.SCSI_HBA_status_error_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 3 | HP SCSI | True | Error | High | True | System |
| HPE Windows (WMI) SCSI physical drive predictive failure. | A SCSI physical drive status is now set to Predictive Failure. | HewlettPackard.Servers.ProLiant.WMI.SCSI_physical_drive_predictive_failure_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 8 | HP SCSI | True | Error | High | True | System |
| HPE Windows (WMI) SCSI storage system power supply degraded. | A Storage Enclosure Power Supply status has changed to non-redundant. | HewlettPackard.Servers.ProLiant.WMI.SCSI_Power_Supply_status_Non_Redundant_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 0 | HP SCSI | True | Warning | High | True | System |
| HPE Windows (WMI) SCSI storage system temperature failed. | A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation. A shutdown is imminent. Action is required before loss of data occurs. | HewlettPackard.Servers.ProLiant.WMI.SCSI_Temperature_sensor_status_Critical_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 309 | HP SCSI | True | Error | High | True | System |
| HPE Windows (WMI) SCSI storage system temperature degraded. | A Storage Enclosure Temperature sensor Status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally. | HewlettPackard.Servers.ProLiant.WMI.SCSI_Temperature_sensor_status_Warning_Condition_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIServerStorage | Alert | True | | | 0 | 308 | HP SCSI | True | Warning | High | True | System |
| HPE Windows (WMI) system configuration should be changed for optimal performance. | The system is not configured for optimal performance as its address mode is currently set to 40-bit instead of the Windows recommended 44-bit mode.
In addition to the larger addressable physical address space, the 44-bit mode improves the system performance by generating less address decoding faults.
| HewlettPackard.Servers.ProLiant.WMI.system_configuration_should_be_changed_for_optimal_performance_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 0 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) System error has been detected . | _Description_ | HewlettPackard.Servers.ProLiant.WMI.System_error_has_been_detected_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 8012 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) system is missing one or more critical QFEs (Quick Fix Engineerings). | Need to update system with critical QFE \%s. | HewlettPackard.Servers.ProLiant.WMI.system_is_missing_one_or_more_critical_QFEs_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 8013 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) System Optimization Alert is disabled. | The user has disabled System Optimization Alert feature. | HewlettPackard.Servers.ProLiant.WMI.System_Optimization_Alert_is_disabled_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIAdvancedServerSettings | Alert | True | | | 0 | 8011 | HP MCHealth | True | Warning | High | True | System |
| HPE Windows (WMI) Temperature threshold exceeded. | A temperature sensor has detected that the temperature has exceeded the normal operating range. | HewlettPackard.Servers.ProLiant.WMI.Temperature_threshold_exceeded_detected_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMITemperatureSensors | Alert | True | | | 0 | 2001 | HP Sensor | True | Error | High | True | System |
| HPE Windows (WMI) Thermal reboot occurred. | The system has rebooted from a thermal shutdown event. | HewlettPackard.Servers.ProLiant.WMI.Thermal_reboot_occurred_Rule | HewlettPackard.Servers.ProLiant.WMI.HPProLiantWMIProcessors | Alert | True | | | 0 | 2 | HP System | True | Warning | High | True | System |