All Unit Monitors in SCUtils.APC.UPS Management Pack

 DisplayNameDescriptionIDTargetParent MonitorCategoryEnabledInstance NameCounter NameFrequencyAlert GenerateAlert SeverityAlert PriorityAlert Auto ResolveMonitor TypeRemotableAccessibilityRunAs
SCUtils.APC.EMU.Monitor.emsProbeStatusProbeCommStatusThe state of communications to the probe The state of communications to the probe. commNeverDiscovered(1) indicates there has never been communications with this device. commsEstablished(2) indicates communication is normal and active with this device. commsLost(3) indicates communication had been established, but is no longer SCUtils.APC.EMU.Monitor.emsProbeStatusProbeCommStatusSCUtils.APC.EMUProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic
SCUtils.APC.EMU.Monitor.EMUHardwareStatusAPC EMU Hardware Status Monitor The status of the EMS hardware. This integer should be interpreted as a bit map, with each bit representing the presence or absence of a specific hardware error condition. 0 indicates there are no error conditions detected in the EMS hardware. 1 indicates a Current Limit error condition related to the Alink port. 2 indicates incorrect hardware is plugged into an EMS port. 3 indicates that both of these error conditions are present. SCUtils.APC.EMU.Monitor.EMUHardwareStatusSCUtils.APC.EMUSystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic
SCUtils.APC.EMU.Monitor.EMUProbeHighHumidityEMU Probe HighHumidity MonitorProbe humidity reading. Values are represented in whole number percentage.SCUtils.APC.EMU.Monitor.EMUProbeHighHumiditySCUtils.APC.EMUProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.GreaterThanThresholdProbeTruePublic
SCUtils.APC.EMU.Monitor.EMUProbeHighTempAPC EMU Probe High Temperature MonitorProbe temperature reading. Values are represented in whole number degrees. Units are displayed in the scale shown in the emsStatusSysTempUnits OID (Celsius or Fahrenheit). SCUtils.APC.EMU.Monitor.EMUProbeHighTempSCUtils.APC.EMUProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.EMUProbeTemperatureTruePublic
SCUtils.APC.EMU.Monitor.EMUProbeLowHumidityAPC EMU Probe Low Humidity MonitorProbe humidity reading. Values are represented in whole number percentage.SCUtils.APC.EMU.Monitor.EMUProbeLowHumiditySCUtils.APC.EMUProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.LessThanThresholdProbeTruePublic
SCUtils.APC.EMU.Monitor.EMUSensorStatusAPC EMU Sensor Status MonitorGetting this variable will return the sensor state. If the sensor is faulted, the sensorFaultedEMS (1) value will be returned. If the sensor is not faulted, the sensorOKEMS (2) value will be returned. If the sensor is not installed, the sensorNotInstalledEMS (3) value will be returned. SCUtils.APC.EMU.Monitor.EMUSensorStatusSCUtils.APC.EMUSensorSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic
SCUtils.APC.UPS.Monitor.iemStatusProbeCurrentHumidyHighiem Status Probe Current Humidy High The current humidity reading from the probe in percent relative humidity. Healthy if than 40-55. SCUtils.APC.UPS.Monitor.iemStatusProbeCurrentHumidyHighSCUtils.APC.UPS.IEM.ProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.GreaterThanThresholdProbeTruePublic
SCUtils.APC.UPS.Monitor.iemStatusProbeCurrentHumidyLowiem Status Probe Current Humidy Low The current humidity reading from the probe in percent relative humidity. Healthy if than 40-55. SCUtils.APC.UPS.Monitor.iemStatusProbeCurrentHumidyLowSCUtils.APC.UPS.IEM.ProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.LessThanThresholdProbeTruePublic
SCUtils.APC.UPS.Monitor.iemStatusProbeHighTempiem Status Probe High Temperature Probe temperature reading. SCUtils.APC.UPS.Monitor.iemStatusProbeHighTempSCUtils.APC.UPS.IEM.ProbeSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.IntEnvMonProbeTemperatureTruePublic
SCUtils.APC.UPS.Monitor.upsAdvBatteryCapacityUPS Battery Capacity Healthy if greater than or equal to 60 percent. The remaining battery capacity expressed in percent of full capacity. SCUtils.APC.UPS.Monitor.upsAdvBatteryCapacitySCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.LessThanThresholdProbeTruePublic
SCUtils.APC.UPS.Monitor.upsAdvBatteryNumOfBadBattPacksUPS Number Of Bad Battery PacksThe number of external battery packs connected to the UPS that are defective. If the UPS does not use smart cells then the agent reports ERROR_NO_SUCH_NAME.SCUtils.APC.UPS.Monitor.upsAdvBatteryNumOfBadBattPacksSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic
SCUtils.APC.UPS.Monitor.upsAdvBatteryReplaceIndicatorUPS Battery Replacement Indicator Healthy if not equal to 2. Monitor warning indicates that there is a UPS battery that needs to be changed. The UPS may not perform as desired should a power failure occur. SCUtils.APC.UPS.Monitor.upsAdvBatteryReplaceIndicatorSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic
SCUtils.APC.UPS.Monitor.upsAdvBatteryRunTimeRemainingUPS Battery RunTime RemainingSCUtils.APC.UPS.Monitor.upsAdvBatteryRunTimeRemainingSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueErrorNormalTrueSCUtils.APC.UPS.MonitorType.BatteryRunTimeTruePublic
SCUtils.APC.UPS.Monitor.upsAdvBatteryTemperatureUPS Battery TemperatureSCUtils.APC.UPS.Monitor.upsAdvBatteryTemperatureSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.GreaterThanThresholdProbeTruePublic
SCUtils.APC.UPS.Monitor.upsAdvOutputLoadUPS Output Load Healthy if less than 50.The current UPS load expressed in percent of rated capacity. SCUtils.APC.UPS.Monitor.upsAdvOutputLoadSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.GreaterThanThresholdProbeTruePublic
SCUtils.APC.UPS.Monitor.upsBasicBatteryStatusUPS Basic Battery Status Healthy if equal to 2. Monitor warning indicates that the battery status is either 'Unknown' (communication with the UPS has been lost) or that the battery is running low and will turn off shortly. This is used as a final warning condition. SCUtils.APC.UPS.Monitor.upsBasicBatteryStatusSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueErrorNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic
SCUtils.APC.UPS.Monitor.upsBasicOutputStatusUPS Basic Output Status Healthy if equal to 2. Monitor warning indicates that the UPS is running on battery (3) or is not providing line voltage to any attached devices. SCUtils.APC.UPS.Monitor.upsBasicOutputStatusSCUtils.APC.UPS.SystemSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueWarningNormalTrueSCUtils.APC.UPS.MonitorType.StatusProbeTruePublic