Dell PRO-enabled Management Pack

Dell.Connections.hyperv.PROPack :: 5.0.0.6 (Management Pack)


Dell PRO-pack optimizes the Microsoft System Center Operation Manager (or Essentials) and Virtual Machine Manager interaction with Dell Server and Storage product lines. When events originating from the Dell Hardware are reported, PRO Tips are generated and provided to the SCVMM console for remedial actions to be taken. Copyright© 2008-2017 Dell Inc. All Rights Reserved.

Summary

DELL PRO-enabled Management Pack for PRO Tips Implementation.

Configuration

N/A

Management Pack Elements

Classes (1)

 DisplayNameIDBase ClassAbstractHostedSingletonGroupExtensionAccessibility
Dell.Propack.DellManagedHostDell PROPack Class for DiscoveryDell.Propack.DellManagedHostMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.PublicFalseTrueFalseFalseFalsePublic

DataSource Modules (2)

 DisplayNameIDIsolationAccessibility
Dell.Propack.DellManagedHost.DiscoveryRuleDell PROPack Discovery ModuleDell.Propack.DellManagedHost.DiscoveryRuleAnyInternal
DellPROEnabledMonitorEventLogDell PROPack Monitors Event LogDellPROEnabledMonitorEventLogAnyInternal

WriteAction Modules (2)

 DisplayNameIDIsolationAccessibility
DellPROEnabled.CreateEventIDDell PROPack Event IDDellPROEnabled.CreateEventIDAnyPublic
DellPROPack.RecoveryActionDell PROPack Recovery ActionDellPROPack.RecoveryActionAnyInternal

Discoveries (1)

 DisplayNameIDTargetEnabled
Dell.Propack.DellManagedHost.DiscoveryDell PROPack Server DiscoveryDell.Propack.DellManagedHost.DiscoveryMicrosoft.SystemCenter.VirtualMachineManager.VMHostTrue

Unit Monitors (97)

 DisplayNameIDTargetCategoryEnabledAlert GenerateAccessibility
DellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerDell OpenManage Storage Services(OMSS) Event: A block on the physical disk has been punctured by the controller.DellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ACPowerSupplyCableFailureDell OpenManage Storage Services(OMSS) Event: The AC power supply cable has been removed.DellProPack.UnitMonitor.ACPowerSupplyCableFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ARedundantPathBrokenDell OpenManage Storage Services(OMSS) Event: A redundant path is broken. DellProPack.UnitMonitor.ARedundantPathBrokenDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BadBlockTable80PercentFullDell OpenManage Storage Services(OMSS) Event: Bad block table is 80\% full. DellProPack.UnitMonitor.BadBlockTable80PercentFullDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BadBlockTableFullDell OpenManage Storage Services(OMSS) Event: Bad block table is full. Unable to log block.DellProPack.UnitMonitor.BadBlockTableFullDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BadDiskBlockReassignErrorDell OpenManage Storage Services(OMSS) Event: A bad disk block could not be reassigned during a write operation. DellProPack.UnitMonitor.BadDiskBlockReassignErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BadPHYDell OpenManage Storage Services(OMSS) Event: Bad PHY DellProPack.UnitMonitor.BadPHYDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BatterySensorWarningDell OpenManage Server Administrator(OMSA) Event: Battery sensor detected a warning value.DellProPack.UnitMonitor.BatterySensorWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BGICompletedWithErrorsDell OpenManage Storage Services(OMSS) Event: The background initialization (BGI) completed with uncorrectable errors.DellProPack.UnitMonitor.BGICompletedWithErrorsDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BGIFailedErrorDell OpenManage Storage Services(OMSS) Event: Background Initialization failed.DellProPack.UnitMonitor.BGIFailedErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.BroadcomNICLinkDownDell OMNIC Broadcom Network Interface Link Down DellProPack.UnitMonitor.BroadcomNICLinkDownDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveDell OpenManage Storage Services(OMSS) Event: Cache device missing and unresponsive.DellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CachedLUNRWFailureDell OpenManage Storage Services(OMSS) Event: Cached LUN Read-Write has failed.DellProPack.UnitMonitor.CachedLUNRWFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CCCompletedUncorrectableErrorDell OpenManage Storage Services(OMSS) Event: The Check Consistency completed with uncorrectable errors.DellProPack.UnitMonitor.CCCompletedUncorrectableErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorDell OpenManage Storage Services(OMSS) Event: The Check Consistency detected uncorrectable multiple medium errors.DellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CommunicationTimeOutWarningDell OpenManage Storage Services(OMSS) Event: Controller communication timeout.DellProPack.UnitMonitor.CommunicationTimeOutWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CommunicationWithEnclosureLostDell OpenManage Storage Services(OMSS) Event: Communication with the enclosure has been lost. DellProPack.UnitMonitor.CommunicationWithEnclosureLostDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControlleDisconnectedFromItsVDDell OpenManage Storage Services(OMSS) Event: Controller cache pinned for missing or offline VD. DellProPack.UnitMonitor.ControlleDisconnectedFromItsVDDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControllerBatteryDegradedDell OpenManage Storage Services(OMSS) Event: The controller battery is degraded. DellProPack.UnitMonitor.ControllerBatteryDegradedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControllerBatteryLearnCycleTimeoutDell OpenManage Storage Services(OMSS) Event: The controller battery Learn cycle has timed out. DellProPack.UnitMonitor.ControllerBatteryLearnCycleTimeoutDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControllerBatteryLowDell OpenManage Storage Services(OMSS) Event: Controller battery low.DellProPack.UnitMonitor.ControllerBatteryLowDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControllerBatteryTempAboveNormalDell OpenManage Storage Services(OMSS) Event: The controller battery temperature is above normal.DellProPack.UnitMonitor.ControllerBatteryTempAboveNormalDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControllerBatteyRemovedDell OpenManage Storage Services(OMSS) Event: The controller battery has been removed.DellProPack.UnitMonitor.ControllerBatteyRemovedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.controllerDIMMCriticallyDegraded Dell OpenManage Storage Services(OMSS) Event: Single-bit ECC error. The controller DIMM is critically degraded. DellProPack.UnitMonitor.controllerDIMMCriticallyDegradedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.ControllerLostCommunicationWithHotSpare Dell OpenManage Storage Services(OMSS) Event: Controller lost communication with hot spare. DellProPack.UnitMonitor.ControllerLostCommunicationWithHotSpareDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CurrentSensorDetectedFailureValueDell OpenManage Server Administrator(OMSA) Event: Current sensor detected a failure value.DellProPack.UnitMonitor.CurrentSensorDetectedFailureValueDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CurrentSensorFailureDell OpenManage Server Administrator(OMSA) Event: A current sensor has failed.DellProPack.UnitMonitor.CurrentSensorFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.CurrentSensorWarningDell OpenManage Server Administrator(OMSA) Event: Current sensor detected a warning valueDellProPack.UnitMonitor.CurrentSensorWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.DCPowerSupplySwitchedOffDell OpenManage Storage Services(OMSS) Event: The DC power supply is switched off.DellProPack.UnitMonitor.DCPowerSupplySwitchedOffDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.DedicatedHotSpareFailedDell OpenManage Storage Services(OMSS) Event: A dedicated hot spare failed.DellProPack.UnitMonitor.DedicatedHotSpareFailedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.DeviceFailedErrorDell OpenManage Storage Services(OMSS) Event: Device failed.DellProPack.UnitMonitor.DeviceFailedErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.DeviceInUnknownStateDell OpenManage Storage Services(OMSS) Event: A device is in an unknown state.DellProPack.UnitMonitor.DeviceInUnknownStateDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.DeviceIsMissingDell OpenManage Storage Services(OMSS) Event: A device is missing. DellProPack.UnitMonitor.DeviceIsMissingDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.DiskMediumErrorDell OpenManage Storage Services(OMSS) Event: Disk medium error detected.DellProPack.UnitMonitor.DiskMediumErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.EMMFailureDell OpenManage Storage Services(OMSS) Event: The Enclosure Management Module has failed.DellProPack.UnitMonitor.EMMFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.EnclosureComponentFailedDell OpenManage Storage Services(OMSS) Event: The enclosure is not responding.DellProPack.UnitMonitor.EnclosureComponentFailedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.EnclosureHardwareErrorDell OpenManage Storage Services(OMSS) Event: The enclosure has a hardware error. DellProPack.UnitMonitor.EnclosureHardwareErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.EnclosureShutdownDell OpenManage Storage Services(OMSS) Event: Enclosure shutdown.DellProPack.UnitMonitor.EnclosureShutdownDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.FanNotFunctioningCorrectlyDell OpenManage Server Administrator(OMSA) Event: A fan is not functioning correctly.DellProPack.UnitMonitor.FanNotFunctioningCorrectlyDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.FanSensorDetectedFailureValueDell OpenManage Server Administrator(OMSA) Event: Fan sensor detected a failure value. DellProPack.UnitMonitor.FanSensorDetectedFailureValueDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.FanSensorFailureDell OpenManage Server Administrator(OMSA) Event: A fan sensor has failed.DellProPack.UnitMonitor.FanSensorFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.GlobalHotSpareFailedDell OpenManage Storage Services(OMSS) Event: A global hot spare failed.DellProPack.UnitMonitor.GlobalHotSpareFailedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.InconsistentParityDataDell OpenManage Storage Services(OMSS) Event: The Check consistency found inconsistent parity data. DellProPack.UnitMonitor.InconsistentParityDataDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.IntelNICLinkDownDell OMNIC Intel Network Interface Link Down DellProPack.UnitMonitor.IntelNICLinkDownDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.MemoryDeviceErrorDell OpenManage Server Administrator(OMSA) Event: Memory device is in error state.DellProPack.UnitMonitor.MemoryDeviceErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.MemoryDeviceStatusWarningDell OpenManage Server Administrator(OMSA) Event: Memory device is in warning stateDellProPack.UnitMonitor.MemoryDeviceStatusWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.MultiBitECCErrorDell OpenManage Storage Services(OMSS) Event: Multi-bit ECC error on controller DIMM.DellProPack.UnitMonitor.MultiBitECCErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.NVRAMHasCorruptData_2328 Dell OpenManage Storage Services(OMSS) Event: The NVRAM has corrupt data. The controller is unable to correct the situation. DellProPack.UnitMonitor.NVRAMHasCorruptData_2328Dell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.NVRAMHasCorruptedData Dell OpenManage Storage Services(OMSS) Event: The NVRAM has corrupted data. The controller is reinitializing the NVRAM. DellProPack.UnitMonitor.NVRAMHasCorruptedDataDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureDell OpenManage Storage Services(OMSS) Event: OMSS - FluidCache communications Failure.DellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorDell OpenManage Storage Services(OMSS) Event: Patrol read found an uncorrectable media error. DellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureDell OpenManage Storage Services(OMSS) Event: A PCIeSSD cache device is no longer functional.DellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PhysicalDiskRebuildFailedDell OpenManage Storage Services(OMSS) Event: Physical disk rebuild failed.DellProPack.UnitMonitor.PhysicalDiskRebuildFailedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PowerSupplyDetectedFailureDell OpenManage Server Administrator(OMSA) Event: Power supply detected a failure.DellProPack.UnitMonitor.PowerSupplyDetectedFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasACFailureDell OpenManage Storage Services(OMSS) Event: A power supply in the enclosure has an AC failure.DellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasACFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasDCFailureDell OpenManage Storage Services(OMSS) Event: A power supply in the enclosure has a DC failure.DellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasDCFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PowerSupplySensorWarningDell OpenManage Server Administrator(OMSA) Event: Power supply sensor warningDellProPack.UnitMonitor.PowerSupplySensorWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.PredictiveDriveError Dell OpenManage Storage Services(OMSS) Event: Predictive Failure reported. DellProPack.UnitMonitor.PredictiveDriveErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.RechargeCountMaximumExceededDell OpenManage Storage Services(OMSS) Event: Recharge count maximum exceeded.DellProPack.UnitMonitor.RechargeCountMaximumExceededDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.RedundancyDegradedDell OpenManage Storage Services(OMSS) Event: Redundancy degraded error.DellProPack.UnitMonitor.RedundancyDegradedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.RedundancyDegradedWarningDell OpenManage Server Administrator(OMSA) Event: Redundancy degraded warningDellProPack.UnitMonitor.RedundancyDegradedWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.RedundancyLostDell OpenManage Storage Services(OMSS) Event: Redundancy lost.DellProPack.UnitMonitor.RedundancyLostDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.RedundancyLostErrorDell OpenManage Server Administrator(OMSA) Event: Redundancy lost errorDellProPack.UnitMonitor.RedundancyLostErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SASComponentsFailureDell OpenManage Storage Services(OMSS) Event: The initialization sequence of SAS components failed during system startup. SAS management and monitoring is not possible. DellProPack.UnitMonitor.SASComponentsFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SASDisksCannotReplaceSATADisksDell OpenManage Storage Services(OMSS) Event: The only hot spare available is a SAS disk. SAS disks cannot replace SATA disks. DellProPack.UnitMonitor.SASDisksCannotReplaceSATADisksDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SASExpanderErrorDell OpenManage Storage Services(OMSS) Event: SAS expander error. DellProPack.UnitMonitor.SASExpanderErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SASPortReportWarningDell OpenManage Storage Services(OMSS) Event: SAS port report warning.DellProPack.UnitMonitor.SASPortReportWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SASSMPCommunicationsErrorDell OpenManage Storage Services(OMSS) Event: SAS SMP communications error.DellProPack.UnitMonitor.SASSMPCommunicationsErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SATADisksCannotReplaceSASDisksDell OpenManage Storage Services(OMSS) Event: The only hot spare available is a SATA disk. SATA disks cannot replace SAS disks.DellProPack.UnitMonitor.SATADisksCannotReplaceSASDisksDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2187Dell OpenManage Storage Services(OMSS) Event: Single-bit ECC error limit exceeded on the controller DIMM.DellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2187Dell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2319Dell OpenManage Storage Services(OMSS) Event: Single-bit ECC error on controller DIMM.DellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2319Dell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperationDell OpenManage Storage Services(OMSS) Event: Single-bit Encountered Error during IO operation. DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperationDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.StorageBatteryChargerErrorDell OpenManage Storage Services(OMSS) Event: The controller battery needs to be replaced.DellProPack.UnitMonitor.StorageBatteryChargerErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.StorageDeviceInaccessibleDell OpenManage Storage Services(OMSS) Event: A storage device is either inaccessible or is no longer functional.DellProPack.UnitMonitor.StorageDeviceInaccessibleDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.StorageManagementcommunicationErrorDell OpenManage Storage Services(OMSS) Event: Storage management has lost communication with the controller.DellProPack.UnitMonitor.StorageManagementcommunicationErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureDroppedBelowMinimumWarningThresholdDell OpenManage Storage Services(OMSS) Event: Temperature dropped below the minimum warning threshold value.DellProPack.UnitMonitor.TemperatureDroppedBelowMinimumWarningThresholdDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdDell OpenManage Storage Services(OMSS) Event: Temperature dropped below the minimum failure threshold value.DellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueDell OpenManage Storage Services(OMSS) Event: Temperature exceeded the maximum failure threshold value.DellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureExceededMaximumWarningThresholdDell OpenManage Storage Services(OMSS) Event: Temperature exceeded the maximum warning threshold.DellProPack.UnitMonitor.TemperatureExceededMaximumWarningThresholdDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureSensorDetectedFailureDell OpenManage Server Administrator(OMSA) Event: Temperature sensor detected a failure valueDellProPack.UnitMonitor.TemperatureSensorDetectedFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureSensorDetectedWarningValueDell OpenManage Server Administrator(OMSA) Event: Temperature sensor detected a warning valueDellProPack.UnitMonitor.TemperatureSensorDetectedWarningValueDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TemperatureSensorFailureDell OpenManage Server Administrator(OMSA) Event: A temperature sensor has failed.DellProPack.UnitMonitor.TemperatureSensorFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TheBatteryHealthPoorDell OpenManage Storage Services(OMSS) Event: The Battery health is poor.DellProPack.UnitMonitor.TheBatteryHealthPoorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalDell OpenManage Storage Services(OMSS) Event: Single-bit ECC error. The controller DIMM is nonfunctional. There will be no further reporting.DellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TheControllerUnableToRecoverDataDell OpenManage Storage Services(OMSS) Event: The controller is unable to recover cached data from the battery backup unit (BBU).DellProPack.UnitMonitor.TheControllerUnableToRecoverDataDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.TheEnclosureHasABadSensorDell OpenManage Storage Services(OMSS) Event: The enclosure has a bad sensor. DellProPack.UnitMonitor.TheEnclosureHasABadSensorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.UnrecoverableDiskMediaErrorDell OpenManage Storage Services(OMSS) Event: Unrecoverable disk media error during the rebuild or recovery operation.DellProPack.UnitMonitor.UnrecoverableDiskMediaErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDDell OpenManage Storage Services(OMSS) Event: There is an unrecoverable medium error detected on virtual disk.DellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.UnstableEnclosureFailureDell OpenManage Storage Services(OMSS) Event: The enclosure is unstable.DellProPack.UnitMonitor.UnstableEnclosureFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VDBadBlockMediumErrorDell OpenManage Storage Services(OMSS) Event: A virtual disk bad block error is detected.DellProPack.UnitMonitor.VDBadBlockMediumErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VirtuaDiskRebuildFailedDell OpenManage Storage Services(OMSS) Event: Virtual disk rebuild failed.DellProPack.UnitMonitor.VirtuaDiskRebuildFailedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedDell OpenManage Storage Services(OMSS) Event: Virtual disk check consistency failed.DellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VirtualDiskDegradedWarningDell OpenManage Storage Services(OMSS) Event: Virtual disk degraded. DellProPack.UnitMonitor.VirtualDiskDegradedWarningDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VirtualDiskFailedErrorDell OpenManage Storage Services(OMSS) Event: Virtual disk failed.DellProPack.UnitMonitor.VirtualDiskFailedErrorDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedDell OpenManage Storage Services(OMSS) Event: A virtual disk is permanently degraded.DellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VoltageSensorDetectedFailureValueDell OpenManage Server Administrator(OMSA) Event: Voltage sensor detected a failure value. DellProPack.UnitMonitor.VoltageSensorDetectedFailureValueDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal
DellProPack.UnitMonitor.VoltageSensorFailureDell OpenManage Server Administrator(OMSA) Event: A voltage sensor has failed.DellProPack.UnitMonitor.VoltageSensorFailureDell.Propack.DellManagedHostAvailabilityHealthFalseTrueInternal

Rules (1)

 DisplayNameIDTargetCategoryEnabledAlert Generate
DellPro.MaintenanceMode.VMHostEventLogMonitoringRuleDell PROPack Rule - Execute PowerShell Script on Operations Manager ServerDellPro.MaintenanceMode.VMHostEventLogMonitoringRuleDell.Propack.DellManagedHostEventCollectionTrueFalse

Recoveries (97)

 DisplayNameIDTargetMonitorReset MonitorCategoryEnabledAccessibility
DellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheControllerDell PROPack: Block on the physical disk punctured by the controller - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheControllerDell.Propack.DellManagedHostDellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ACPowerSupplyCableFailureDell PROPack: AC Power supply cable failure - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.ACPowerSupplyCableFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.ACPowerSupplyCableFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ARedundantPathBrokenDell PROPack: Redundant Path Broken - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.ARedundantPathBrokenDell.Propack.DellManagedHostDellProPack.UnitMonitor.ARedundantPathBrokenFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ASSMPCommunicationsErrorDell OpenManage Storage Services(OMSS) Event: ASSMP Communications Error - Place server in restricted modeDellProPack.Recovery.ASSMPCommunicationsErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.SASSMPCommunicationsErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BadBlockTable80PercentFullDell OpenManage Storage Services(OMSS) Event: Bad Block Table 80\% Full - Place server in restricted modeDellProPack.Recovery.BadBlockTable80PercentFullDell.Propack.DellManagedHostDellProPack.UnitMonitor.BadBlockTable80PercentFullFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BadBlockTableFullDell OpenManage Storage Services(OMSS) Event: Bad Block Table Full - Place server in restricted modeDellProPack.Recovery.BadBlockTableFullDell.Propack.DellManagedHostDellProPack.UnitMonitor.BadBlockTableFullFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BadDiskBlockReassignErrorDell OpenManage Storage Services(OMSS) Event: Bad Disk Block Reassign Error - Place server in restricted modeDellProPack.Recovery.BadDiskBlockReassignErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.BadDiskBlockReassignErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BadPHYDell OpenManage Storage Services(OMSS) Event: Bad PHY - Place server in restricted modeDellProPack.Recovery.BadPHYDell.Propack.DellManagedHostDellProPack.UnitMonitor.BadPHYFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BatterySensorWarningDell PROPack: Battery Sensor Warning - Place server in restricted modeDellProPack.Recovery.BatterySensorWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.BatterySensorWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BGICompletedWithErrorsDell PROPack: BGI Completed with errors - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.BGICompletedWithErrorsDell.Propack.DellManagedHostDellProPack.UnitMonitor.BGICompletedWithErrorsFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BGIFailedErrorDell PROPack: BGI Failed Error - Place server in restricted modeDellProPack.Recovery.BGIFailedErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.BGIFailedErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.BroadcomNICLinkDownDell OMNIC Broadcom Network Interface Link Down - Place server in restricted modeDellProPack.Recovery.BroadcomNICLinkDownDell.Propack.DellManagedHostDellProPack.UnitMonitor.BroadcomNICLinkDownFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CacheDeviceMissingUnresponsiveDell PROPack: Cache device missing and unresponsive - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.CacheDeviceMissingUnresponsiveDell.Propack.DellManagedHostDellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CachedLUNRWFailureDell PROPack: Cached LUN Read-Write has failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.CachedLUNRWFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.CachedLUNRWFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CCCompletedUncorrectableErrorDell OpenManage Storage Services(OMSS) Event: The Check Consistency completed with uncorrectable errors - Restrict and Migrate Virtual Machine(s)from this host.DellProPack.Recovery.CCCompletedUncorrectableErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.CCCompletedUncorrectableErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CCDetectedUncorrectableMeduimErrorDell OpenManage Storage Services(OMSS) Event: The Check Consistency detected uncorrectable multiple medium errors - Place server in restricted mode.DellProPack.Recovery.CCDetectedUncorrectableMeduimErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CommunicationTimeOutWarningDell PROPack: Communication Timeout Warning - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.CommunicationTimeOutWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.CommunicationTimeOutWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CommunicationWithEnclosureLostDell PROPack: Communication with the enclosure has been lost - Restrict and Migrate Virtual Machine(s)from this host.DellProPack.Recovery.CommunicationWithEnclosureLostDell.Propack.DellManagedHostDellProPack.UnitMonitor.CommunicationWithEnclosureLostFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControlleDisconnectedFromItsVDDell OpenManage Storage Services(OMSS) Event: Controller disconnected from its VD - Place server in restricted modeDellProPack.Recovery.ControlleDisconnectedFromItsVDDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControlleDisconnectedFromItsVDFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControllerBatteryDegradedDell OpenManage Storage Services(OMSS) Event: Controller Battery Degraded - Place server in restricted modeDellProPack.Recovery.ControllerBatteryDegradedDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControllerBatteryDegradedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControllerBatteryLearnCycleTimeoutDell OpenManage Storage Services(OMSS) Event: Controller Battery Learn Cycle Timeout - Place server in restricted modeDellProPack.Recovery.ControllerBatteryLearnCycleTimeoutDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControllerBatteryLearnCycleTimeoutFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControllerBatteryLowDell OpenManage Storage Services(OMSS) Event: Controller Battery Low - Place server in restricted modeDellProPack.Recovery.ControllerBatteryLowDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControllerBatteryLowFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControllerBatteryTempAboveNormalDell OpenManage Storage Services(OMSS) Event: Controller Battery Temperature Above Normal - Place server in restricted modeDellProPack.Recovery.ControllerBatteryTempAboveNormalDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControllerBatteryTempAboveNormalFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControllerBatteyRemovedDell PROPack: Controller Battery Removed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.ControllerBatteyRemovedDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControllerBatteyRemovedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.controllerDIMMCriticallyDegradedDell PROPack: Controller DIMM Critically Degraded - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.controllerDIMMCriticallyDegradedDell.Propack.DellManagedHostDellProPack.UnitMonitor.controllerDIMMCriticallyDegradedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.ControllerLostCommunicationWithHotSpareDell OpenManage Storage Services(OMSS) Event: Controller Lost Communication with Hot Spare - Place server in restricted modeDellProPack.Recovery.ControllerLostCommunicationWithHotSpareDell.Propack.DellManagedHostDellProPack.UnitMonitor.ControllerLostCommunicationWithHotSpareFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CurrentSensorDetectedFailureValueDell PROPack: Current Sensor Detected Failure Value - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.CurrentSensorDetectedFailureValueDell.Propack.DellManagedHostDellProPack.UnitMonitor.CurrentSensorDetectedFailureValueFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CurrentSensorFailureDell PROPack: A current sensor has failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.CurrentSensorFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.CurrentSensorFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.CurrentSensorWarningDell PROPack: Current Sensor Warning - Place server in restricted modeDellProPack.Recovery.CurrentSensorWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.CurrentSensorWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.DCPowerSupplySwitchedOffDell PROPack: DC PowerSupply Switched Off - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.DCPowerSupplySwitchedOffDell.Propack.DellManagedHostDellProPack.UnitMonitor.DCPowerSupplySwitchedOffFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.DedicatedHotSpareFailedDell OpenManage Storage Services(OMSS) Event: Dedicated Hot Spare Failed - Place server in restricted modeDellProPack.Recovery.DedicatedHotSpareFailedDell.Propack.DellManagedHostDellProPack.UnitMonitor.DedicatedHotSpareFailedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.DeviceFailedErrorDell PROPack: Device Failed Error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.DeviceFailedErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.DeviceFailedErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.DeviceInUnknownStateDell PROPack: Device in unknown state - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.DeviceInUnknownStateDell.Propack.DellManagedHostDellProPack.UnitMonitor.DeviceInUnknownStateFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.DeviceIsMissingDell OpenManage Storage Services(OMSS) Event: Device is missing - Place server in restricted modeDellProPack.Recovery.DeviceIsMissingDell.Propack.DellManagedHostDellProPack.UnitMonitor.DeviceIsMissingFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.DiskMediumErrorDell OpenManage Storage Services(OMSS) Event: Disk medium error detected - Place server in restricted mode.DellProPack.Recovery.DiskMediumErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.DiskMediumErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.EMMFailureDell PROPack: EMM Failure - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.EMMFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.EMMFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.EnclosureComponentFailedDell PROPack: Enclosure Component Failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.EnclosureComponentFailedDell.Propack.DellManagedHostDellProPack.UnitMonitor.EnclosureComponentFailedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.EnclosureHardwareErrorDell PROPack: Enclosure Hardware Error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.EnclosureHardwareErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.EnclosureHardwareErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.EnclosureShutdownDell PROPack: Enclosure Shutdown - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.EnclosureShutdownDell.Propack.DellManagedHostDellProPack.UnitMonitor.EnclosureShutdownFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.FanNotFunctioningCorrectlyDell PROPack: A fan is not functioning correctly - Place server in restricted mode.DellProPack.Recovery.FanNotFunctioningCorrectlyDell.Propack.DellManagedHostDellProPack.UnitMonitor.FanNotFunctioningCorrectlyFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.FanSensorDetectedFailureValueDell PROPack: Fan Sensor Detected Failure Value - Place server in restricted modeDellProPack.Recovery.FanSensorDetectedFailureValueDell.Propack.DellManagedHostDellProPack.UnitMonitor.FanSensorDetectedFailureValueFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.FanSensorFailureDell PROPack: A fan sensor has failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.FanSensorFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.FanSensorFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.GlobalHotSpareFailedDell OpenManage Storage Services(OMSS) Event: Global Hot Spare Failed - Place server in restricted modeDellProPack.Recovery.GlobalHotSpareFailedDell.Propack.DellManagedHostDellProPack.UnitMonitor.GlobalHotSpareFailedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.InconsistentParityDataDell PROPack: Inconsistent parity data - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.InconsistentParityDataDell.Propack.DellManagedHostDellProPack.UnitMonitor.InconsistentParityDataFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.IntelNICLinkDownDell OMNIC Intel Network Interface Link Down - Place server in restricted modeDellProPack.Recovery.IntelNICLinkDownDell.Propack.DellManagedHostDellProPack.UnitMonitor.IntelNICLinkDownFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.MemoryDeviceErrorDell PROPack: Memory Device Error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.MemoryDeviceErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.MemoryDeviceErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.MemoryDeviceStatusWarningDell PROPack: Memory Device Status Warning - Place server in restricted modeDellProPack.Recovery.MemoryDeviceStatusWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.MemoryDeviceStatusWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.MultiBitECCErrorDell PROPack: Multi Bit ECC Error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.MultiBitECCErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.MultiBitECCErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.NVRAMHasCorruptData_2328Dell PROPack: NVRAM has corrupt data - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.NVRAMHasCorruptData_2328Dell.Propack.DellManagedHostDellProPack.UnitMonitor.NVRAMHasCorruptData_2328FalseAvailabilityHealthfalseInternal
DellProPack.Recovery.NVRAMHasCorruptedDataDell PROPack: NVRAM has corrupted data - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.NVRAMHasCorruptedDataDell.Propack.DellManagedHostDellProPack.UnitMonitor.NVRAMHasCorruptedDataFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.OMSSFluidCacheCommunicationsFailureDell PROPack: OMSS - FluidCache communications Failure - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.OMSSFluidCacheCommunicationsFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PatrolReadUncorrectableMediaErrorDell PROPack: Patrol Read Uncorrectable Media Error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.PatrolReadUncorrectableMediaErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PCIeSSDCacheDeviceFailureDell PROPack: A PCIeSSD cache device is no longer functional - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.PCIeSSDCacheDeviceFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PhysicalDiskRebuildFailedDell PROPack: Physical Disk Rebuild Failed - Place server in restricted modeDellProPack.Recovery.PhysicalDiskRebuildFailedDell.Propack.DellManagedHostDellProPack.UnitMonitor.PhysicalDiskRebuildFailedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PowerSupplyDetectedFailureDell PROPack: Power Supply Detected Failure - Place server in restricted modeDellProPack.Recovery.PowerSupplyDetectedFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.PowerSupplyDetectedFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PowerSupplyInTheEnclosureHasACFailureDell OpenManage Storage Services(OMSS) Event: PowerSupply in the Enclosure has AC Failure - Place server in restricted modeDellProPack.Recovery.PowerSupplyInTheEnclosureHasACFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasACFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PowerSupplyInTheEnclosureHasDCFailureDell OpenManage Storage Services(OMSS) Event: PowerSupply in the Enclosure has DC Failure - Place server in restricted modeDellProPack.Recovery.PowerSupplyInTheEnclosureHasDCFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasDCFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PowerSupplySensorWarningDell PROPack: Power Supply Sensor Warning - Place server in restricted modeDellProPack.Recovery.PowerSupplySensorWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.PowerSupplySensorWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.PredictiveDriveErrorDell OpenManage Storage Services(OMSS) Event: Predictive Failure reported - Place server in restricted modeDellProPack.Recovery.PredictiveDriveErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.PredictiveDriveErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.RechargeCountMaximumExceededDell OpenManage Storage Services(OMSS) Event: Recharge Count Maximum Exceeded - Place server in restricted modeDellProPack.Recovery.RechargeCountMaximumExceededDell.Propack.DellManagedHostDellProPack.UnitMonitor.RechargeCountMaximumExceededFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.RedundancyDegradedDell OpenManage Storage Services(OMSS) Event: Redundancy Degraded - Place server in restricted modeDellProPack.Recovery.RedundancyDegradedDell.Propack.DellManagedHostDellProPack.UnitMonitor.RedundancyDegradedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.RedundancyDegradedWarningDell PROPack: Redundancy Degraded Warning - Place server in restricted modeDellProPack.Recovery.RedundancyDegradedWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.RedundancyDegradedWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.RedundancyLostDell OpenManage Storage Services(OMSS) Event: Redundancy Lost - Place server in restricted modeDellProPack.Recovery.RedundancyLostDell.Propack.DellManagedHostDellProPack.UnitMonitor.RedundancyLostFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.RedundancyLostErrorDell PROPack: Redundancy Lost Error - Place server in restricted modeDellProPack.Recovery.RedundancyLostErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.RedundancyLostErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SASComponentsFailureDell PROPack: SAS Components Failure - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.SASComponentsFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.SASComponentsFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SASDisksCannotReplaceSATADisksDell OpenManage Storage Services(OMSS) Event: SAS Disks cannot replace SATA Disks - Place server in restricted modeDellProPack.Recovery.SASDisksCannotReplaceSATADisksDell.Propack.DellManagedHostDellProPack.UnitMonitor.SASDisksCannotReplaceSATADisksFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SASExpanderErrorDell OpenManage Storage Services(OMSS) Event: SAS Expander Error - Place server in restricted modeDellProPack.Recovery.SASExpanderErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.SASExpanderErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SASPortReportWarningDell PROPack: SAS Port Report Warning - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.SASPortReportWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.SASPortReportWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SATADisksCannotReplaceSASDisksDell OpenManage Storage Services(OMSS) Event: SATA Disks cannot replace SAS Disks - Place server in restricted modeDellProPack.Recovery.SATADisksCannotReplaceSASDisksDell.Propack.DellManagedHostDellProPack.UnitMonitor.SATADisksCannotReplaceSASDisksFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2187Dell PROPack: Single bit ECC error on controller DIMM - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2187Dell.Propack.DellManagedHostDellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2187FalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2319Dell OpenManage Storage Services(OMSS) Event: Single Bit ECC Error On Controller DIMM - Place server in restricted modeDellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2319Dell.Propack.DellManagedHostDellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2319FalseAvailabilityHealthfalseInternal
DellProPack.Recovery.SingleBitEncounteredErrorDuringIOoperationDell OpenManage Storage Services(OMSS) Event: Single bit encountered error during IO operation - Place server in restricted modeDellProPack.Recovery.SingleBitEncounteredErrorDuringIOoperationDell.Propack.DellManagedHostDellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperationFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.StorageBatteryChargerErrorDell PROPack: The controller battery needs to be replaced - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.StorageBatteryChargerErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.StorageBatteryChargerErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.StorageDeviceInaccessibleDell PROPack: A storage device is either inaccessible or is no longer functional - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.StorageDeviceInaccessibleDell.Propack.DellManagedHostDellProPack.UnitMonitor.StorageDeviceInaccessibleFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.StorageManagementcommunicationErrorDell PROPack: Storage management communication error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.StorageManagementcommunicationErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.StorageManagementcommunicationErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureDroppedBelowMinimumWarningThresholdDell PROPack: Temperature dropped below minimum warning threshold - Place server in restricted modeDellProPack.Recovery.TemperatureDroppedBelowMinimumWarningThresholdDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureDroppedBelowMinimumWarningThresholdFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThresholdDell PROPack: Temperature dropped below the minimum failure threshold - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThresholdDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureExceededMaximumThresholdValueDell PROPack: Temperature exceeded maximum threshold value - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.TemperatureExceededMaximumThresholdValueDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureExceededMaximumWarningThresholdDell PROPack: Temperature exceeded maximum warning threshold - Place server in restricted modeDellProPack.Recovery.TemperatureExceededMaximumWarningThresholdDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureExceededMaximumWarningThresholdFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureSensorDetectedFailureDell PROPack: Temperature Sensor Detected Failure - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.TemperatureSensorDetectedFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureSensorDetectedFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureSensorDetectedWarningValueDell PROPack: Temperature Sensor Detected Warning Value - Place server in restricted modeDellProPack.Recovery.TemperatureSensorDetectedWarningValueDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureSensorDetectedWarningValueFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TemperatureSensorFailureDell PROPack: A temperature sensor has failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.TemperatureSensorFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.TemperatureSensorFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TheBatteryHealthPoorDell OpenManage Storage Services(OMSS) Event: Battery Health Poor - Place server in restricted modeDellProPack.Recovery.TheBatteryHealthPoorDell.Propack.DellManagedHostDellProPack.UnitMonitor.TheBatteryHealthPoorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TheControllerDIMMIsnonfunctionalDell PROPack: Controller DIMM is nonfunctional - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.TheControllerDIMMIsnonfunctionalDell.Propack.DellManagedHostDellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TheControllerUnableToRecoverDataDell OpenManage Storage Services(OMSS) Event: Controller unable to recover data - Place server in restricted modeDellProPack.Recovery.TheControllerUnableToRecoverDataDell.Propack.DellManagedHostDellProPack.UnitMonitor.TheControllerUnableToRecoverDataFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.TheEnclosureHasABadSensorDell OpenManage Storage Services(OMSS) Event: Enclosure has a Bad Sensor - Place server in restricted modeDellProPack.Recovery.TheEnclosureHasABadSensorDell.Propack.DellManagedHostDellProPack.UnitMonitor.TheEnclosureHasABadSensorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.UnrecoverableDiskMediaErrorDell OpenManage Storage Services(OMSS) Event: Unrecoverable Disk Media Error - Place server in restricted modeDellProPack.Recovery.UnrecoverableDiskMediaErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.UnrecoverableDiskMediaErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.UnrecoverableMediumErrorDetectedVDDell OpenManage Storage Services(OMSS) Event: There is an unrecoverable medium error detected on virtual disk - Restrict and Migrate Virtual Machine(s)from this host.DellProPack.Recovery.UnrecoverableMediumErrorDetectedVDDell.Propack.DellManagedHostDellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.UnstableEnclosureFailureDell PROPack: Unstable Enclosure Failure - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.UnstableEnclosureFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.UnstableEnclosureFailureFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VDBadBlockMediumErrorDell OpenManage Storage Services(OMSS) Event: Virtual disk bad block medium error is detected - Restrict and Migrate Virtual Machine(s)from this host.DellProPack.Recovery.VDBadBlockMediumErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.VDBadBlockMediumErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VirtuaDiskRebuildFailedDell PROPack: Virtual Disk Rebuild Failed - Place server in restricted modeDellProPack.Recovery.VirtuaDiskRebuildFailedDell.Propack.DellManagedHostDellProPack.UnitMonitor.VirtuaDiskRebuildFailedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VirtualDiskCheckConsistencyFailedDell PROPack: Virtual disk check consistency failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.VirtualDiskCheckConsistencyFailedDell.Propack.DellManagedHostDellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VirtualDiskDegradedWarningDell PROPack: Virtual disk degraded warning - Place server in restricted modeDellProPack.Recovery.VirtualDiskDegradedWarningDell.Propack.DellManagedHostDellProPack.UnitMonitor.VirtualDiskDegradedWarningFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VirtualDiskFailedErrorDell PROPack: Virtual disk failed error - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.VirtualDiskFailedErrorDell.Propack.DellManagedHostDellProPack.UnitMonitor.VirtualDiskFailedErrorFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VirtualDiskPermanentlyDegradedDell PROPack: Virtual Disk Permanently Degraded - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.VirtualDiskPermanentlyDegradedDell.Propack.DellManagedHostDellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VoltageSensorDetectedFailureValueDell PROPack: Voltage Sensor Detected Failure Value - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.VoltageSensorDetectedFailureValueDell.Propack.DellManagedHostDellProPack.UnitMonitor.VoltageSensorDetectedFailureValueFalseAvailabilityHealthfalseInternal
DellProPack.Recovery.VoltageSensorFailureDell PROPack: A voltage sensor has failed - Restrict and Migrate Virtual Machine(s) from this host.DellProPack.Recovery.VoltageSensorFailureDell.Propack.DellManagedHostDellProPack.UnitMonitor.VoltageSensorFailureFalseAvailabilityHealthfalseInternal

Monitor Property Overrides (152)

 IDContextTarget
DellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerCDellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheController
DellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerWCDellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheControllerWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ABlockOnThePhysicalDiskpuncturedByTheController
DellProPack.UnitMonitor.ACPowerSupplyCableFailureWCDellProPack.UnitMonitor.ACPowerSupplyCableFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ACPowerSupplyCableFailure
DellProPack.UnitMonitor.ARedundantPathBrokenWCDellProPack.UnitMonitor.ARedundantPathBrokenWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ARedundantPathBroken
DellProPack.UnitMonitor.BadBlockTable80PercentFullWCDellProPack.UnitMonitor.BadBlockTable80PercentFullWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BadBlockTable80PercentFull
DellProPack.UnitMonitor.BadBlockTableFullCDellProPack.UnitMonitor.BadBlockTableFullCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.BadBlockTableFull
DellProPack.UnitMonitor.BadBlockTableFullWCDellProPack.UnitMonitor.BadBlockTableFullWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BadBlockTableFull
DellProPack.UnitMonitor.BadDiskBlockReassignErrorCDellProPack.UnitMonitor.BadDiskBlockReassignErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.BadDiskBlockReassignError
DellProPack.UnitMonitor.BadDiskBlockReassignErrorWCDellProPack.UnitMonitor.BadDiskBlockReassignErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BadDiskBlockReassignError
DellProPack.UnitMonitor.BadPHYWCDellProPack.UnitMonitor.BadPHYWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BadPHY
DellProPack.UnitMonitor.BatterySensorWarningWCDellProPack.UnitMonitor.BatterySensorWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BatterySensorWarning
DellProPack.UnitMonitor.BGICompletedWithErrorsCDellProPack.UnitMonitor.BGICompletedWithErrorsCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.BGICompletedWithErrors
DellProPack.UnitMonitor.BGICompletedWithErrorsWCDellProPack.UnitMonitor.BGICompletedWithErrorsWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BGICompletedWithErrors
DellProPack.UnitMonitor.BGIFailedErrorCDellProPack.UnitMonitor.BGIFailedErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.BGIFailedError
DellProPack.UnitMonitor.BGIFailedErrorWCDellProPack.UnitMonitor.BGIFailedErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BGIFailedError
DellProPack.UnitMonitor.BroadcomNICLinkDownCDellProPack.UnitMonitor.BroadcomNICLinkDownCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.BroadcomNICLinkDown
DellProPack.UnitMonitor.BroadcomNICLinkDownWCDellProPack.UnitMonitor.BroadcomNICLinkDownWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.BroadcomNICLinkDown
DellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveCDellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CacheDeviceMissingUnresponsive
DellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveWCDellProPack.UnitMonitor.CacheDeviceMissingUnresponsiveWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CacheDeviceMissingUnresponsive
DellProPack.UnitMonitor.CachedLUNRWFailureCDellProPack.UnitMonitor.CachedLUNRWFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CachedLUNRWFailure
DellProPack.UnitMonitor.CachedLUNRWFailureWCDellProPack.UnitMonitor.CachedLUNRWFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CachedLUNRWFailure
DellProPack.UnitMonitor.CCCompletedUncorrectableErrorCDellProPack.UnitMonitor.CCCompletedUncorrectableErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CCCompletedUncorrectableError
DellProPack.UnitMonitor.CCCompletedUncorrectableErrorWCDellProPack.UnitMonitor.CCCompletedUncorrectableErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CCCompletedUncorrectableError
DellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorCDellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CCDetectedUncorrectableMeduimError
DellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorWCDellProPack.UnitMonitor.CCDetectedUncorrectableMeduimErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CCDetectedUncorrectableMeduimError
DellProPack.UnitMonitor.CommunicationTimeOutWarningWCDellProPack.UnitMonitor.CommunicationTimeOutWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CommunicationTimeOutWarning
DellProPack.UnitMonitor.CommunicationWithEnclosureLostCDellProPack.UnitMonitor.CommunicationWithEnclosureLostCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CommunicationWithEnclosureLost
DellProPack.UnitMonitor.CommunicationWithEnclosureLostWCDellProPack.UnitMonitor.CommunicationWithEnclosureLostWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CommunicationWithEnclosureLost
DellProPack.UnitMonitor.ControlleDisconnectedFromItsVDWcDellProPack.UnitMonitor.ControlleDisconnectedFromItsVDWcMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControlleDisconnectedFromItsVD
DellProPack.UnitMonitor.ControllerBatteryDegradedWCDellProPack.UnitMonitor.ControllerBatteryDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControllerBatteryDegraded
DellProPack.UnitMonitor.ControllerBatteryLearnCycleTimeoutWCDellProPack.UnitMonitor.ControllerBatteryLearnCycleTimeoutWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControllerBatteryLearnCycleTimeout
DellProPack.UnitMonitor.ControllerBatteryLowWCDellProPack.UnitMonitor.ControllerBatteryLowWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControllerBatteryLow
DellProPack.UnitMonitor.ControllerBatteryTempAboveNormalWCDellProPack.UnitMonitor.ControllerBatteryTempAboveNormalWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControllerBatteryTempAboveNormal
DellProPack.UnitMonitor.ControllerBatteyRemovedWCDellProPack.UnitMonitor.ControllerBatteyRemovedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControllerBatteyRemoved
DellProPack.UnitMonitor.controllerDIMMCriticallyDegradedCDellProPack.UnitMonitor.controllerDIMMCriticallyDegradedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.controllerDIMMCriticallyDegraded
DellProPack.UnitMonitor.controllerDIMMCriticallyDegradedWCDellProPack.UnitMonitor.controllerDIMMCriticallyDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.controllerDIMMCriticallyDegraded
DellProPack.UnitMonitor.ControllerLostCommunicationWithHotSpareWCDellProPack.UnitMonitor.ControllerLostCommunicationWithHotSpareWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.ControllerLostCommunicationWithHotSpare
DellProPack.UnitMonitor.CurrentSensorDetectedFailureValueCDellProPack.UnitMonitor.CurrentSensorDetectedFailureValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CurrentSensorDetectedFailureValue
DellProPack.UnitMonitor.CurrentSensorDetectedFailureValueWCDellProPack.UnitMonitor.CurrentSensorDetectedFailureValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CurrentSensorDetectedFailureValue
DellProPack.UnitMonitor.CurrentSensorFailureCDellProPack.UnitMonitor.CurrentSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.CurrentSensorFailure
DellProPack.UnitMonitor.CurrentSensorFailureWCDellProPack.UnitMonitor.CurrentSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CurrentSensorFailure
DellProPack.UnitMonitor.CurrentSensorWarningWCDellProPack.UnitMonitor.CurrentSensorWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.CurrentSensorWarning
DellProPack.UnitMonitor.DCPowerSupplySwitchedOffWCDellProPack.UnitMonitor.DCPowerSupplySwitchedOffWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.DCPowerSupplySwitchedOff
DellProPack.UnitMonitor.DedicatedHotSpareFailedWCDellProPack.UnitMonitor.DedicatedHotSpareFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.DedicatedHotSpareFailed
DellProPack.UnitMonitor.DeviceFailedErrorCDellProPack.UnitMonitor.DeviceFailedErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.DeviceFailedError
DellProPack.UnitMonitor.DeviceFailedErrorWCDellProPack.UnitMonitor.DeviceFailedErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.DeviceFailedError
DellProPack.UnitMonitor.DeviceInUnknownStateCDellProPack.UnitMonitor.DeviceInUnknownStateCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.DeviceInUnknownState
DellProPack.UnitMonitor.DeviceInUnknownStateWCDellProPack.UnitMonitor.DeviceInUnknownStateWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.DeviceInUnknownState
DellProPack.UnitMonitor.DeviceIsMissingWCDellProPack.UnitMonitor.DeviceIsMissingWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.DeviceIsMissing
DellProPack.UnitMonitor.DiskMediumErrorCDellProPack.UnitMonitor.DiskMediumErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.DiskMediumError
DellProPack.UnitMonitor.DiskMediumErrorWCDellProPack.UnitMonitor.DiskMediumErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.DiskMediumError
DellProPack.UnitMonitor.EMMFailureCDellProPack.UnitMonitor.EMMFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.EMMFailure
DellProPack.UnitMonitor.EMMFailureWCDellProPack.UnitMonitor.EMMFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.EMMFailure
DellProPack.UnitMonitor.EnclosureComponentFailedCDellProPack.UnitMonitor.EnclosureComponentFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.EnclosureComponentFailed
DellProPack.UnitMonitor.EnclosureComponentFailedWCDellProPack.UnitMonitor.EnclosureComponentFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.EnclosureComponentFailed
DellProPack.UnitMonitor.EnclosureHardwareErrorCDellProPack.UnitMonitor.EnclosureHardwareErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.EnclosureHardwareError
DellProPack.UnitMonitor.EnclosureHardwareErrorWCDellProPack.UnitMonitor.EnclosureHardwareErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.EnclosureHardwareError
DellProPack.UnitMonitor.EnclosureShutdownCDellProPack.UnitMonitor.EnclosureShutdownCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.EnclosureShutdown
DellProPack.UnitMonitor.EnclosureShutdownWCDellProPack.UnitMonitor.EnclosureShutdownWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.EnclosureShutdown
DellProPack.UnitMonitor.FanNotFunctioningCorrectlyCDellProPack.UnitMonitor.FanNotFunctioningCorrectlyCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.FanNotFunctioningCorrectly
DellProPack.UnitMonitor.FanNotFunctioningCorrectlyWCDellProPack.UnitMonitor.FanNotFunctioningCorrectlyWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.FanNotFunctioningCorrectly
DellProPack.UnitMonitor.FanSensorDetectedFailureValueCDellProPack.UnitMonitor.FanSensorDetectedFailureValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.FanSensorDetectedFailureValue
DellProPack.UnitMonitor.FanSensorDetectedFailureValueWCDellProPack.UnitMonitor.FanSensorDetectedFailureValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.FanSensorDetectedFailureValue
DellProPack.UnitMonitor.FanSensorFailureCDellProPack.UnitMonitor.FanSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.FanSensorFailure
DellProPack.UnitMonitor.FanSensorFailureWCDellProPack.UnitMonitor.FanSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.FanSensorFailure
DellProPack.UnitMonitor.GlobalHotSpareFailedWCDellProPack.UnitMonitor.GlobalHotSpareFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.GlobalHotSpareFailed
DellProPack.UnitMonitor.InconsistentParityDataWCDellProPack.UnitMonitor.InconsistentParityDataWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.InconsistentParityData
DellProPack.UnitMonitor.IntelNICLinkDownCDellProPack.UnitMonitor.IntelNICLinkDownCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.IntelNICLinkDown
DellProPack.UnitMonitor.IntelNICLinkDownWCDellProPack.UnitMonitor.IntelNICLinkDownWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.IntelNICLinkDown
DellProPack.UnitMonitor.MemoryDeviceErrorCDellProPack.UnitMonitor.MemoryDeviceErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.MemoryDeviceError
DellProPack.UnitMonitor.MemoryDeviceErrorWCDellProPack.UnitMonitor.MemoryDeviceErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.MemoryDeviceError
DellProPack.UnitMonitor.MemoryDeviceStatusWarningWCDellProPack.UnitMonitor.MemoryDeviceStatusWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.MemoryDeviceStatusWarning
DellProPack.UnitMonitor.MultiBitECCErrorCDellProPack.UnitMonitor.MultiBitECCErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.MultiBitECCError
DellProPack.UnitMonitor.MultiBitECCErrorWCDellProPack.UnitMonitor.MultiBitECCErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.MultiBitECCError
DellProPack.UnitMonitor.NVRAMHasCorruptData_2328WCDellProPack.UnitMonitor.NVRAMHasCorruptData_2328WCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.NVRAMHasCorruptData_2328
DellProPack.UnitMonitor.NVRAMHasCorruptedDataWCDellProPack.UnitMonitor.NVRAMHasCorruptedDataWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.NVRAMHasCorruptedData
DellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureCDellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailure
DellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureWCDellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.OMSSFluidCacheCommunicationsFailure
DellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorCDellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.PatrolReadUncorrectableMediaError
DellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorWCDellProPack.UnitMonitor.PatrolReadUncorrectableMediaErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PatrolReadUncorrectableMediaError
DellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureCDellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.PCIeSSDCacheDeviceFailure
DellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureWCDellProPack.UnitMonitor.PCIeSSDCacheDeviceFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PCIeSSDCacheDeviceFailure
DellProPack.UnitMonitor.PhysicalDiskRebuildFailedCDellProPack.UnitMonitor.PhysicalDiskRebuildFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.PhysicalDiskRebuildFailed
DellProPack.UnitMonitor.PhysicalDiskRebuildFailedWCDellProPack.UnitMonitor.PhysicalDiskRebuildFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PhysicalDiskRebuildFailed
DellProPack.UnitMonitor.PowerSupplyDetectedFailureCDellProPack.UnitMonitor.PowerSupplyDetectedFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.PowerSupplyDetectedFailure
DellProPack.UnitMonitor.PowerSupplyDetectedFailureWCDellProPack.UnitMonitor.PowerSupplyDetectedFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PowerSupplyDetectedFailure
DellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasACFailureWCDellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasACFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasACFailure
DellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasDCFailureWCDellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasDCFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PowerSupplyInTheEnclosureHasDCFailure
DellProPack.UnitMonitor.PowerSupplySensorWarningWCDellProPack.UnitMonitor.PowerSupplySensorWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PowerSupplySensorWarning
DellProPack.UnitMonitor.PredictiveDriveErrorWCDellProPack.UnitMonitor.PredictiveDriveErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.PredictiveDriveError
DellProPack.UnitMonitor.RechargeCountMaximumExceededWCDellProPack.UnitMonitor.RechargeCountMaximumExceededWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.RechargeCountMaximumExceeded
DellProPack.UnitMonitor.RedundancyDegradedWarningWCDellProPack.UnitMonitor.RedundancyDegradedWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.RedundancyDegradedWarning
DellProPack.UnitMonitor.RedundancyDegradedWCDellProPack.UnitMonitor.RedundancyDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.RedundancyDegraded
DellProPack.UnitMonitor.RedundancyLostErrorCDellProPack.UnitMonitor.RedundancyLostErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.RedundancyLostError
DellProPack.UnitMonitor.RedundancyLostErrorWCDellProPack.UnitMonitor.RedundancyLostErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.RedundancyLostError
DellProPack.UnitMonitor.RedundancyLostWCDellProPack.UnitMonitor.RedundancyLostWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.RedundancyLost
DellProPack.UnitMonitor.SASComponentsFailureCDellProPack.UnitMonitor.SASComponentsFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.SASComponentsFailure
DellProPack.UnitMonitor.SASComponentsFailureWCDellProPack.UnitMonitor.SASComponentsFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SASComponentsFailure
DellProPack.UnitMonitor.SASDisksCannotReplaceSATADisksWCDellProPack.UnitMonitor.SASDisksCannotReplaceSATADisksWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SASDisksCannotReplaceSATADisks
DellProPack.UnitMonitor.SASExpanderErrorCDellProPack.UnitMonitor.SASExpanderErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.SASExpanderError
DellProPack.UnitMonitor.SASExpanderErrorWCDellProPack.UnitMonitor.SASExpanderErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SASExpanderError
DellProPack.UnitMonitor.SASPortReportWarningWCDellProPack.UnitMonitor.SASPortReportWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SASPortReportWarning
DellProPack.UnitMonitor.SASSMPCommunicationsErrorCDellProPack.UnitMonitor.SASSMPCommunicationsErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.SASSMPCommunicationsError
DellProPack.UnitMonitor.SASSMPCommunicationsErrorWCDellProPack.UnitMonitor.SASSMPCommunicationsErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SASSMPCommunicationsError
DellProPack.UnitMonitor.SATADisksCannotReplaceSASDisksWCDellProPack.UnitMonitor.SATADisksCannotReplaceSASDisksWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SATADisksCannotReplaceSASDisks
DellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2187WCDellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2187WCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2187
DellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2319WCDellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2319WCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SingleBitECCErrorOnControllerDIMM_2319
DellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperationWCDellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperationWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.SingleBitEncounteredErrorDuringIOoperation
DellProPack.UnitMonitor.StorageBatteryChargerErrorCDellProPack.UnitMonitor.StorageBatteryChargerErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.StorageBatteryChargerError
DellProPack.UnitMonitor.StorageBatteryChargerErrorWCDellProPack.UnitMonitor.StorageBatteryChargerErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.StorageBatteryChargerError
DellProPack.UnitMonitor.StorageDeviceInaccessibleCDellProPack.UnitMonitor.StorageDeviceInaccessibleCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.StorageDeviceInaccessible
DellProPack.UnitMonitor.StorageDeviceInaccessibleWCDellProPack.UnitMonitor.StorageDeviceInaccessibleWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.StorageDeviceInaccessible
DellProPack.UnitMonitor.StorageManagementcommunicationErrorCDellProPack.UnitMonitor.StorageManagementcommunicationErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.StorageManagementcommunicationError
DellProPack.UnitMonitor.StorageManagementcommunicationErrorWCDellProPack.UnitMonitor.StorageManagementcommunicationErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.StorageManagementcommunicationError
DellProPack.UnitMonitor.TemperatureDroppedBelowMinimumWarningThresholdWCDellProPack.UnitMonitor.TemperatureDroppedBelowMinimumWarningThresholdWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureDroppedBelowMinimumWarningThreshold
DellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdCDellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThreshold
DellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdWCDellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThresholdWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureDroppedBelowTheMinimumFailureThreshold
DellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueCDellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValue
DellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueWCDellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureExceededMaximumThresholdValue
DellProPack.UnitMonitor.TemperatureExceededMaximumWarningThresholdWCDellProPack.UnitMonitor.TemperatureExceededMaximumWarningThresholdWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureExceededMaximumWarningThreshold
DellProPack.UnitMonitor.TemperatureSensorDetectedFailureCDellProPack.UnitMonitor.TemperatureSensorDetectedFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.TemperatureSensorDetectedFailure
DellProPack.UnitMonitor.TemperatureSensorDetectedFailureWCDellProPack.UnitMonitor.TemperatureSensorDetectedFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureSensorDetectedFailure
DellProPack.UnitMonitor.TemperatureSensorDetectedWarningValueWCDellProPack.UnitMonitor.TemperatureSensorDetectedWarningValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureSensorDetectedWarningValue
DellProPack.UnitMonitor.TemperatureSensorFailureCDellProPack.UnitMonitor.TemperatureSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.TemperatureSensorFailure
DellProPack.UnitMonitor.TemperatureSensorFailureWCDellProPack.UnitMonitor.TemperatureSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TemperatureSensorFailure
DellProPack.UnitMonitor.TheBatteryHealthPoorWCDellProPack.UnitMonitor.TheBatteryHealthPoorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TheBatteryHealthPoor
DellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalCDellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.TheControllerDIMMIsnonfunctional
DellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalWCDellProPack.UnitMonitor.TheControllerDIMMIsnonfunctionalWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TheControllerDIMMIsnonfunctional
DellProPack.UnitMonitor.TheControllerUnableToRecoverDataCDellProPack.UnitMonitor.TheControllerUnableToRecoverDataCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.TheControllerUnableToRecoverData
DellProPack.UnitMonitor.TheControllerUnableToRecoverDataWCDellProPack.UnitMonitor.TheControllerUnableToRecoverDataWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TheControllerUnableToRecoverData
DellProPack.UnitMonitor.TheEnclosureHasABadSensorWCDellProPack.UnitMonitor.TheEnclosureHasABadSensorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.TheEnclosureHasABadSensor
DellProPack.UnitMonitor.UnrecoverableDiskMediaErrorCDellProPack.UnitMonitor.UnrecoverableDiskMediaErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.UnrecoverableDiskMediaError
DellProPack.UnitMonitor.UnrecoverableDiskMediaErrorWCDellProPack.UnitMonitor.UnrecoverableDiskMediaErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.UnrecoverableDiskMediaError
DellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDCDellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVD
DellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDWCDellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVDWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.UnrecoverableMediumErrorDetectedVD
DellProPack.UnitMonitor.UnstableEnclosureFailureCDellProPack.UnitMonitor.UnstableEnclosureFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.UnstableEnclosureFailure
DellProPack.UnitMonitor.UnstableEnclosureFailureWCDellProPack.UnitMonitor.UnstableEnclosureFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.UnstableEnclosureFailure
DellProPack.UnitMonitor.VDBadBlockMediumErrorCDellProPack.UnitMonitor.VDBadBlockMediumErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VDBadBlockMediumError
DellProPack.UnitMonitor.VDBadBlockMediumErrorWCDellProPack.UnitMonitor.VDBadBlockMediumErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VDBadBlockMediumError
DellProPack.UnitMonitor.VirtuaDiskRebuildFailedCDellProPack.UnitMonitor.VirtuaDiskRebuildFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VirtuaDiskRebuildFailed
DellProPack.UnitMonitor.VirtuaDiskRebuildFailedWCDellProPack.UnitMonitor.VirtuaDiskRebuildFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VirtuaDiskRebuildFailed
DellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedCDellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailed
DellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedWCDellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VirtualDiskCheckConsistencyFailed
DellProPack.UnitMonitor.VirtualDiskDegradedWarningWCDellProPack.UnitMonitor.VirtualDiskDegradedWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VirtualDiskDegradedWarning
DellProPack.UnitMonitor.VirtualDiskFailedErrorCDellProPack.UnitMonitor.VirtualDiskFailedErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VirtualDiskFailedError
DellProPack.UnitMonitor.VirtualDiskFailedErrorWCDellProPack.UnitMonitor.VirtualDiskFailedErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VirtualDiskFailedError
DellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedCDellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VirtualDiskPermanentlyDegraded
DellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedWCDellProPack.UnitMonitor.VirtualDiskPermanentlyDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VirtualDiskPermanentlyDegraded
DellProPack.UnitMonitor.VoltageSensorDetectedFailureValueCDellProPack.UnitMonitor.VoltageSensorDetectedFailureValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VoltageSensorDetectedFailureValue
DellProPack.UnitMonitor.VoltageSensorDetectedFailureValueWCDellProPack.UnitMonitor.VoltageSensorDetectedFailureValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VoltageSensorDetectedFailureValue
DellProPack.UnitMonitor.VoltageSensorFailureCDellProPack.UnitMonitor.VoltageSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableC.GroupDellProPack.UnitMonitor.VoltageSensorFailure
DellProPack.UnitMonitor.VoltageSensorFailureWCDellProPack.UnitMonitor.VoltageSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.EnableWC.GroupDellProPack.UnitMonitor.VoltageSensorFailure

Recovery Property Overrides (154)

 IDContextTarget
DellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheControllerCDellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheControllerCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheController
DellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheControllerWCDellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheControllerWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ABlockOnThePhysicalDiskpuncturedByTheController
DellProPack.Recovery.ACPowerSupplyCableFailureWCDellProPack.Recovery.ACPowerSupplyCableFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ACPowerSupplyCableFailure
DellProPack.Recovery.ARedundantPathBrokenWCDellProPack.Recovery.ARedundantPathBrokenWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ARedundantPathBroken
DellProPack.Recovery.ASSMPCommunicationsErrorWCDellProPack.Recovery.ASSMPCommunicationsErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ASSMPCommunicationsError
DellProPack.Recovery.BadBlockTable80PercentFullWCDellProPack.Recovery.BadBlockTable80PercentFullWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BadBlockTable80PercentFull
DellProPack.Recovery.BadBlockTableFullCDellProPack.Recovery.BadBlockTableFullCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.BadBlockTableFull
DellProPack.Recovery.BadBlockTableFullWCDellProPack.Recovery.BadBlockTableFullWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BadBlockTableFull
DellProPack.Recovery.BadDiskBlockReassignErrorCDellProPack.Recovery.BadDiskBlockReassignErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.BadDiskBlockReassignError
DellProPack.Recovery.BadDiskBlockReassignErrorWCDellProPack.Recovery.BadDiskBlockReassignErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BadDiskBlockReassignError
DellProPack.Recovery.BadPHYWCDellProPack.Recovery.BadPHYWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BadPHY
DellProPack.Recovery.BatterySensorWarningWCDellProPack.Recovery.BatterySensorWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BatterySensorWarning
DellProPack.Recovery.BGICompletedWithErrorsCDellProPack.Recovery.BGICompletedWithErrorsCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.BGICompletedWithErrors
DellProPack.Recovery.BGICompletedWithErrorsWCDellProPack.Recovery.BGICompletedWithErrorsWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BGICompletedWithErrors
DellProPack.Recovery.BGIFailedErrorCDellProPack.Recovery.BGIFailedErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.BGIFailedError
DellProPack.Recovery.BGIFailedErrorWCDellProPack.Recovery.BGIFailedErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BGIFailedError
DellProPack.Recovery.BroadcomNICLinkDownCDellProPack.Recovery.BroadcomNICLinkDownCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.BroadcomNICLinkDown
DellProPack.Recovery.BroadcomNICLinkDownWCDellProPack.Recovery.BroadcomNICLinkDownWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.BroadcomNICLinkDown
DellProPack.Recovery.CacheDeviceMissingUnresponsiveCDellProPack.Recovery.CacheDeviceMissingUnresponsiveCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CacheDeviceMissingUnresponsive
DellProPack.Recovery.CacheDeviceMissingUnresponsiveWCDellProPack.Recovery.CacheDeviceMissingUnresponsiveWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CacheDeviceMissingUnresponsive
DellProPack.Recovery.CachedLUNRWFailureCDellProPack.Recovery.CachedLUNRWFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CachedLUNRWFailure
DellProPack.Recovery.CachedLUNRWFailureWCDellProPack.Recovery.CachedLUNRWFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CachedLUNRWFailure
DellProPack.Recovery.CCCompletedUncorrectableErrorCDellProPack.Recovery.CCCompletedUncorrectableErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CCCompletedUncorrectableError
DellProPack.Recovery.CCCompletedUncorrectableErrorWCDellProPack.Recovery.CCCompletedUncorrectableErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CCCompletedUncorrectableError
DellProPack.Recovery.CCDetectedUncorrectableMeduimErrorCDellProPack.Recovery.CCDetectedUncorrectableMeduimErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CCDetectedUncorrectableMeduimError
DellProPack.Recovery.CCDetectedUncorrectableMeduimErrorWCDellProPack.Recovery.CCDetectedUncorrectableMeduimErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CCDetectedUncorrectableMeduimError
DellProPack.Recovery.CommunicationTimeOutWarningWCDellProPack.Recovery.CommunicationTimeOutWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CommunicationTimeOutWarning
DellProPack.Recovery.CommunicationWithEnclosureLostCDellProPack.Recovery.CommunicationWithEnclosureLostCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CommunicationWithEnclosureLost
DellProPack.Recovery.CommunicationWithEnclosureLostWCDellProPack.Recovery.CommunicationWithEnclosureLostWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CommunicationWithEnclosureLost
DellProPack.Recovery.ControlleDisconnectedFromItsVDWCDellProPack.Recovery.ControlleDisconnectedFromItsVDWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControlleDisconnectedFromItsVD
DellProPack.Recovery.ControllerBatteryDegradedWCDellProPack.Recovery.ControllerBatteryDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControllerBatteryDegraded
DellProPack.Recovery.ControllerBatteryLearnCycleTimeoutWCDellProPack.Recovery.ControllerBatteryLearnCycleTimeoutWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControllerBatteryLearnCycleTimeout
DellProPack.Recovery.ControllerBatteryLowWCDellProPack.Recovery.ControllerBatteryLowWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControllerBatteryLow
DellProPack.Recovery.ControllerBatteryTempAboveNormalWCDellProPack.Recovery.ControllerBatteryTempAboveNormalWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControllerBatteryTempAboveNormal
DellProPack.Recovery.ControllerBatteyRemovedWCDellProPack.Recovery.ControllerBatteyRemovedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControllerBatteyRemoved
DellProPack.Recovery.controllerDIMMCriticallyDegradedCDellProPack.Recovery.controllerDIMMCriticallyDegradedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.controllerDIMMCriticallyDegraded
DellProPack.Recovery.controllerDIMMCriticallyDegradedWCDellProPack.Recovery.controllerDIMMCriticallyDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.controllerDIMMCriticallyDegraded
DellProPack.Recovery.ControllerLostCommunicationWithHotSpareWCDellProPack.Recovery.ControllerLostCommunicationWithHotSpareWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.ControllerLostCommunicationWithHotSpare
DellProPack.Recovery.CurrentSensorDetectedFailureValueCDellProPack.Recovery.CurrentSensorDetectedFailureValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CurrentSensorDetectedFailureValue
DellProPack.Recovery.CurrentSensorDetectedFailureValueWCDellProPack.Recovery.CurrentSensorDetectedFailureValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CurrentSensorDetectedFailureValue
DellProPack.Recovery.CurrentSensorFailureCDellProPack.Recovery.CurrentSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.CurrentSensorFailure
DellProPack.Recovery.CurrentSensorFailureWCDellProPack.Recovery.CurrentSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CurrentSensorFailure
DellProPack.Recovery.CurrentSensorWarningWCDellProPack.Recovery.CurrentSensorWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.CurrentSensorWarning
DellProPack.Recovery.DCPowerSupplySwitchedOffWCDellProPack.Recovery.DCPowerSupplySwitchedOffWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.DCPowerSupplySwitchedOff
DellProPack.Recovery.DedicatedHotSpareFailedWCDellProPack.Recovery.DedicatedHotSpareFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.DedicatedHotSpareFailed
DellProPack.Recovery.DeviceFailedErrorCDellProPack.Recovery.DeviceFailedErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.DeviceFailedError
DellProPack.Recovery.DeviceFailedErrorWCDellProPack.Recovery.DeviceFailedErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.DeviceFailedError
DellProPack.Recovery.DeviceInUnknownStateCDellProPack.Recovery.DeviceInUnknownStateCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.DeviceInUnknownState
DellProPack.Recovery.DeviceInUnknownStateWCDellProPack.Recovery.DeviceInUnknownStateWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.DeviceInUnknownState
DellProPack.Recovery.DeviceIsMissingWCDellProPack.Recovery.DeviceIsMissingWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.DeviceIsMissing
DellProPack.Recovery.DiskMediumErrorCDellProPack.Recovery.DiskMediumErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.DiskMediumError
DellProPack.Recovery.DiskMediumErrorWCDellProPack.Recovery.DiskMediumErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.DiskMediumError
DellProPack.Recovery.EMMFailureCDellProPack.Recovery.EMMFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.EMMFailure
DellProPack.Recovery.EMMFailureWCDellProPack.Recovery.EMMFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.EMMFailure
DellProPack.Recovery.EnclosureComponentFailedCDellProPack.Recovery.EnclosureComponentFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.EnclosureComponentFailed
DellProPack.Recovery.EnclosureComponentFailedWCDellProPack.Recovery.EnclosureComponentFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.EnclosureComponentFailed
DellProPack.Recovery.EnclosureHardwareErrorCDellProPack.Recovery.EnclosureHardwareErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.EnclosureHardwareError
DellProPack.Recovery.EnclosureHardwareErrorWCDellProPack.Recovery.EnclosureHardwareErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.EnclosureHardwareError
DellProPack.Recovery.EnclosureShutdownCDellProPack.Recovery.EnclosureShutdownCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.EnclosureShutdown
DellProPack.Recovery.EnclosureShutdownWCDellProPack.Recovery.EnclosureShutdownWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.EnclosureShutdown
DellProPack.Recovery.FanNotFunctioningCorrectlyCDellProPack.Recovery.FanNotFunctioningCorrectlyCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.FanNotFunctioningCorrectly
DellProPack.Recovery.FanNotFunctioningCorrectlyWCDellProPack.Recovery.FanNotFunctioningCorrectlyWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.FanNotFunctioningCorrectly
DellProPack.Recovery.FanSensorDetectedFailureValueCDellProPack.Recovery.FanSensorDetectedFailureValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.FanSensorDetectedFailureValue
DellProPack.Recovery.FanSensorDetectedFailureValueWCDellProPack.Recovery.FanSensorDetectedFailureValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.FanSensorDetectedFailureValue
DellProPack.Recovery.FanSensorFailureCDellProPack.Recovery.FanSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.FanSensorFailure
DellProPack.Recovery.FanSensorFailureWCDellProPack.Recovery.FanSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.FanSensorFailure
DellProPack.Recovery.GlobalHotSpareFailedWCDellProPack.Recovery.GlobalHotSpareFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.GlobalHotSpareFailed
DellProPack.Recovery.InconsistentParityDataWCDellProPack.Recovery.InconsistentParityDataWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.InconsistentParityData
DellProPack.Recovery.IntelNICLinkDownCDellProPack.Recovery.IntelNICLinkDownCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.IntelNICLinkDown
DellProPack.Recovery.IntelNICLinkDownWCDellProPack.Recovery.IntelNICLinkDownWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.IntelNICLinkDown
DellProPack.Recovery.MemoryDeviceErrorCDellProPack.Recovery.MemoryDeviceErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.MemoryDeviceError
DellProPack.Recovery.MemoryDeviceErrorWCDellProPack.Recovery.MemoryDeviceErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.MemoryDeviceError
DellProPack.Recovery.MemoryDeviceStatusWarningWCDellProPack.Recovery.MemoryDeviceStatusWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.MemoryDeviceStatusWarning
DellProPack.Recovery.MultiBitECCErrorCDellProPack.Recovery.MultiBitECCErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.MultiBitECCError
DellProPack.Recovery.MultiBitECCErrorWCDellProPack.Recovery.MultiBitECCErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.MultiBitECCError
DellProPack.Recovery.NVRAMHasCorruptData_2328WCDellProPack.Recovery.NVRAMHasCorruptData_2328WCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.NVRAMHasCorruptData_2328
DellProPack.Recovery.NVRAMHasCorruptedDataWCDellProPack.Recovery.NVRAMHasCorruptedDataWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.NVRAMHasCorruptedData
DellProPack.Recovery.OMSSFluidCacheCommunicationsFailureCDellProPack.Recovery.OMSSFluidCacheCommunicationsFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.OMSSFluidCacheCommunicationsFailure
DellProPack.Recovery.OMSSFluidCacheCommunicationsFailureWCDellProPack.Recovery.OMSSFluidCacheCommunicationsFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.OMSSFluidCacheCommunicationsFailure
DellProPack.Recovery.PatrolReadUncorrectableMediaErrorCDellProPack.Recovery.PatrolReadUncorrectableMediaErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.PatrolReadUncorrectableMediaError
DellProPack.Recovery.PatrolReadUncorrectableMediaErrorWCDellProPack.Recovery.PatrolReadUncorrectableMediaErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PatrolReadUncorrectableMediaError
DellProPack.Recovery.PCIeSSDCacheDeviceFailureCDellProPack.Recovery.PCIeSSDCacheDeviceFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.PCIeSSDCacheDeviceFailure
DellProPack.Recovery.PCIeSSDCacheDeviceFailureWCDellProPack.Recovery.PCIeSSDCacheDeviceFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PCIeSSDCacheDeviceFailure
DellProPack.Recovery.PhysicalDiskRebuildFailedCDellProPack.Recovery.PhysicalDiskRebuildFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.PhysicalDiskRebuildFailed
DellProPack.Recovery.PhysicalDiskRebuildFailedWCDellProPack.Recovery.PhysicalDiskRebuildFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PhysicalDiskRebuildFailed
DellProPack.Recovery.PowerSupplyDetectedFailureCDellProPack.Recovery.PowerSupplyDetectedFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.PowerSupplyDetectedFailure
DellProPack.Recovery.PowerSupplyDetectedFailureWCDellProPack.Recovery.PowerSupplyDetectedFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PowerSupplyDetectedFailure
DellProPack.Recovery.PowerSupplyInTheEnclosureHasACFailureWCDellProPack.Recovery.PowerSupplyInTheEnclosureHasACFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PowerSupplyInTheEnclosureHasACFailure
DellProPack.Recovery.PowerSupplyInTheEnclosureHasDCFailureWCDellProPack.Recovery.PowerSupplyInTheEnclosureHasDCFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PowerSupplyInTheEnclosureHasDCFailure
DellProPack.Recovery.PowerSupplySensorWarningWCDellProPack.Recovery.PowerSupplySensorWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PowerSupplySensorWarning
DellProPack.Recovery.PredictiveDriveErrorWCDellProPack.Recovery.PredictiveDriveErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.PredictiveDriveError
DellProPack.Recovery.RechargeCountMaximumExceededWCDellProPack.Recovery.RechargeCountMaximumExceededWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.RechargeCountMaximumExceeded
DellProPack.Recovery.RedundancyDegradedWarningCDellProPack.Recovery.RedundancyDegradedWarningCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.RedundancyDegradedWarning
DellProPack.Recovery.RedundancyDegradedWarningWCDellProPack.Recovery.RedundancyDegradedWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.RedundancyDegradedWarning
DellProPack.Recovery.RedundancyDegradedWCDellProPack.Recovery.RedundancyDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.RedundancyDegraded
DellProPack.Recovery.RedundancyLostErrorCDellProPack.Recovery.RedundancyLostErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.RedundancyLostError
DellProPack.Recovery.RedundancyLostErrorWCDellProPack.Recovery.RedundancyLostErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.RedundancyLostError
DellProPack.Recovery.RedundancyLostWCDellProPack.Recovery.RedundancyLostWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.RedundancyLost
DellProPack.Recovery.SASComponentsFailureCDellProPack.Recovery.SASComponentsFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.SASComponentsFailure
DellProPack.Recovery.SASComponentsFailureWCDellProPack.Recovery.SASComponentsFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SASComponentsFailure
DellProPack.Recovery.SASDisksCannotReplaceSATADisksWCDellProPack.Recovery.SASDisksCannotReplaceSATADisksWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SASDisksCannotReplaceSATADisks
DellProPack.Recovery.SASExpanderErrorCDellProPack.Recovery.SASExpanderErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.SASExpanderError
DellProPack.Recovery.SASExpanderErrorWCDellProPack.Recovery.SASExpanderErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SASExpanderError
DellProPack.Recovery.SASPortReportWarningWCDellProPack.Recovery.SASPortReportWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SASPortReportWarning
DellProPack.Recovery.SASSMPCommunicationsErrorCDellProPack.Recovery.SASSMPCommunicationsErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.SASSMPCommunicationsError
DellProPack.Recovery.SASSMPCommunicationsErrorWCDellProPack.Recovery.SASSMPCommunicationsErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SASSMPCommunicationsError
DellProPack.Recovery.SATADisksCannotReplaceSASDisksWCDellProPack.Recovery.SATADisksCannotReplaceSASDisksWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SATADisksCannotReplaceSASDisks
DellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2187WCDellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2187WCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2187
DellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2319WCDellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2319WCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SingleBitECCErrorOnControllerDIMM_2319
DellProPack.Recovery.SingleBitEncounteredErrorDuringIOoperationWCDellProPack.Recovery.SingleBitEncounteredErrorDuringIOoperationWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.SingleBitEncounteredErrorDuringIOoperation
DellProPack.Recovery.StorageBatteryChargerErrorCDellProPack.Recovery.StorageBatteryChargerErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.StorageBatteryChargerError
DellProPack.Recovery.StorageBatteryChargerErrorWCDellProPack.Recovery.StorageBatteryChargerErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.StorageBatteryChargerError
DellProPack.Recovery.StorageDeviceInaccessibleCDellProPack.Recovery.StorageDeviceInaccessibleCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.StorageDeviceInaccessible
DellProPack.Recovery.StorageDeviceInaccessibleWCDellProPack.Recovery.StorageDeviceInaccessibleWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.StorageDeviceInaccessible
DellProPack.Recovery.StorageManagementcommunicationErrorCDellProPack.Recovery.StorageManagementcommunicationErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.StorageManagementcommunicationError
DellProPack.Recovery.StorageManagementcommunicationErrorWCDellProPack.Recovery.StorageManagementcommunicationErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.StorageManagementcommunicationError
DellProPack.Recovery.TemperatureDroppedBelowMinimumWarningThresholdWCDellProPack.Recovery.TemperatureDroppedBelowMinimumWarningThresholdWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureDroppedBelowMinimumWarningThreshold
DellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThresholdCDellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThresholdCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThreshold
DellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThresholdWCDellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThresholdWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureDroppedBelowTheMinimumFailureThreshold
DellProPack.Recovery.TemperatureExceededMaximumThresholdValueCDellProPack.Recovery.TemperatureExceededMaximumThresholdValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.TemperatureExceededMaximumThresholdValue
DellProPack.Recovery.TemperatureExceededMaximumThresholdValueWCDellProPack.Recovery.TemperatureExceededMaximumThresholdValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureExceededMaximumThresholdValue
DellProPack.Recovery.TemperatureExceededMaximumWarningThresholdWCDellProPack.Recovery.TemperatureExceededMaximumWarningThresholdWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureExceededMaximumWarningThreshold
DellProPack.Recovery.TemperatureSensorDetectedFailureCDellProPack.Recovery.TemperatureSensorDetectedFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.TemperatureSensorDetectedFailure
DellProPack.Recovery.TemperatureSensorDetectedFailureWCDellProPack.Recovery.TemperatureSensorDetectedFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureSensorDetectedFailure
DellProPack.Recovery.TemperatureSensorDetectedWarningValueWCDellProPack.Recovery.TemperatureSensorDetectedWarningValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureSensorDetectedWarningValue
DellProPack.Recovery.TemperatureSensorFailureCDellProPack.Recovery.TemperatureSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.TemperatureSensorFailure
DellProPack.Recovery.TemperatureSensorFailureWCDellProPack.Recovery.TemperatureSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TemperatureSensorFailure
DellProPack.Recovery.TheBatteryHealthPoorWCDellProPack.Recovery.TheBatteryHealthPoorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TheBatteryHealthPoor
DellProPack.Recovery.TheControllerDIMMIsnonfunctionalCDellProPack.Recovery.TheControllerDIMMIsnonfunctionalCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.TheControllerDIMMIsnonfunctional
DellProPack.Recovery.TheControllerDIMMIsnonfunctionalWCDellProPack.Recovery.TheControllerDIMMIsnonfunctionalWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TheControllerDIMMIsnonfunctional
DellProPack.Recovery.TheControllerUnableToRecoverDataCDellProPack.Recovery.TheControllerUnableToRecoverDataCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.TheControllerUnableToRecoverData
DellProPack.Recovery.TheControllerUnableToRecoverDataWCDellProPack.Recovery.TheControllerUnableToRecoverDataWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TheControllerUnableToRecoverData
DellProPack.Recovery.TheEnclosureHasABadSensorWCDellProPack.Recovery.TheEnclosureHasABadSensorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.TheEnclosureHasABadSensor
DellProPack.Recovery.UnrecoverableDiskMediaErrorCDellProPack.Recovery.UnrecoverableDiskMediaErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.UnrecoverableDiskMediaError
DellProPack.Recovery.UnrecoverableDiskMediaErrorWCDellProPack.Recovery.UnrecoverableDiskMediaErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.UnrecoverableDiskMediaError
DellProPack.Recovery.UnrecoverableMediumErrorDetectedVDCDellProPack.Recovery.UnrecoverableMediumErrorDetectedVDCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.UnrecoverableMediumErrorDetectedVD
DellProPack.Recovery.UnrecoverableMediumErrorDetectedVDWCDellProPack.Recovery.UnrecoverableMediumErrorDetectedVDWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.UnrecoverableMediumErrorDetectedVD
DellProPack.Recovery.UnstableEnclosureFailureCDellProPack.Recovery.UnstableEnclosureFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.UnstableEnclosureFailure
DellProPack.Recovery.UnstableEnclosureFailureWCDellProPack.Recovery.UnstableEnclosureFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.UnstableEnclosureFailure
DellProPack.Recovery.VDBadBlockMediumErrorCDellProPack.Recovery.VDBadBlockMediumErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VDBadBlockMediumError
DellProPack.Recovery.VDBadBlockMediumErrorWCDellProPack.Recovery.VDBadBlockMediumErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VDBadBlockMediumError
DellProPack.Recovery.VirtuaDiskRebuildFailedCDellProPack.Recovery.VirtuaDiskRebuildFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VirtuaDiskRebuildFailed
DellProPack.Recovery.VirtuaDiskRebuildFailedWCDellProPack.Recovery.VirtuaDiskRebuildFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VirtuaDiskRebuildFailed
DellProPack.Recovery.VirtualDiskCheckConsistencyFailedCDellProPack.Recovery.VirtualDiskCheckConsistencyFailedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VirtualDiskCheckConsistencyFailed
DellProPack.Recovery.VirtualDiskCheckConsistencyFailedWCDellProPack.Recovery.VirtualDiskCheckConsistencyFailedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VirtualDiskCheckConsistencyFailed
DellProPack.Recovery.VirtualDiskDegradedWarningWCDellProPack.Recovery.VirtualDiskDegradedWarningWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VirtualDiskDegradedWarning
DellProPack.Recovery.VirtualDiskFailedErrorCDellProPack.Recovery.VirtualDiskFailedErrorCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VirtualDiskFailedError
DellProPack.Recovery.VirtualDiskFailedErrorWCDellProPack.Recovery.VirtualDiskFailedErrorWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VirtualDiskFailedError
DellProPack.Recovery.VirtualDiskPermanentlyDegradedCDellProPack.Recovery.VirtualDiskPermanentlyDegradedCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VirtualDiskPermanentlyDegraded
DellProPack.Recovery.VirtualDiskPermanentlyDegradedWCDellProPack.Recovery.VirtualDiskPermanentlyDegradedWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VirtualDiskPermanentlyDegraded
DellProPack.Recovery.VoltageSensorDetectedFailureValueCDellProPack.Recovery.VoltageSensorDetectedFailureValueCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VoltageSensorDetectedFailureValue
DellProPack.Recovery.VoltageSensorDetectedFailureValueWCDellProPack.Recovery.VoltageSensorDetectedFailureValueWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VoltageSensorDetectedFailureValue
DellProPack.Recovery.VoltageSensorFailureCDellProPack.Recovery.VoltageSensorFailureCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryC.GroupDellProPack.Recovery.VoltageSensorFailure
DellProPack.Recovery.VoltageSensorFailureWCDellProPack.Recovery.VoltageSensorFailureWCMicrosoft.SystemCenter.VirtualMachineManager.Pro.2008.RecoveryWC.GroupDellProPack.Recovery.VoltageSensorFailure

Folder Items (2)

 DisplayNameIDFolderNameElementID
DellProPack.View.ActiveAlertsDell Server PRO AlertsDellProPack.View.ActiveAlertsDellProPack.ViewFolder.RootDellProPack.View.ActiveAlerts
DellProPack.View.ActiveStateViewDell PROPack Monitored ServersDellProPack.View.ActiveStateViewDellProPack.ViewFolder.RootDellProPack.View.ActiveStateView

Folders (1)

 DisplayNameIDParentFolderAccessibility
DellProPack.ViewFolder.RootDell Server PROPackDellProPack.ViewFolder.RootMicrosoft.SystemCenter.Monitoring.ViewFolder.RootPublic

Image References (1)

 DisplayNameIDImageID
Dell.Propack.DellManagedHostDell PROPack Class for DiscoveryDell.Propack.DellManagedHostDell.Connections.hyperv.PROPack2.Image

Views (2)

 DisplayNameIDTargetTypeAccessibilityVisible
DellProPack.View.ActiveAlertsDell Server PRO AlertsDellProPack.View.ActiveAlertsDell.Propack.DellManagedHostMicrosoft.SystemCenter.AlertViewTypeInternalTrue
DellProPack.View.ActiveStateViewDell PROPack Monitored ServersDellProPack.View.ActiveStateViewDell.Propack.DellManagedHostMicrosoft.SystemCenter.StateViewTypePublicTrue

Images (1)

 IDFile NameAccessibility
Dell.Connections.hyperv.PROPack2.ImageDell.Connections.hyperv.PROPack2.ImageDell.Connections.hyperv.PROPack2.Image.pngInternal