Fujitsu PRIMERGY Windows Servers RAID.MIB Alerts

Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts :: 8.1.6.0 (Management Pack)


This Management Pack (MP) contains the detailed alert rules for the RAID.MIB.
Copyright (C) Fujitsu Technology Solutions 2008 - 2014.

Management Pack Elements

Rules (406)

 DisplayNameIDTargetCategoryEnabledAlert Generate
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10002Write access of the ServerView RAID Manager revoked [RAID_MIB_10002]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10002Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10003BBU temperature out of range [RAID_MIB_10003]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10003Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10004BBU temperature unstable [RAID_MIB_10004]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10004Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10005BBU temperature above threshold [RAID_MIB_10005]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10005Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10006BBU Voltage out of range [RAID_MIB_10006]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10006Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10007BBU Voltage unstable [RAID_MIB_10007]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10007Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10008BBU Voltage below threshold [RAID_MIB_10008]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10008Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10009BBU communication error [RAID_MIB_10009]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10009Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10013BBU failed [RAID_MIB_10013]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10013Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10014BBU fast charging failed [RAID_MIB_10014]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10014Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10015BBU charge count exceeded [RAID_MIB_10015]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10015Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10016BBU needs reconditioning [RAID_MIB_10016]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10016Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10022Disk marked offline [RAID_MIB_10022]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10022Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10023Disk timed out [RAID_MIB_10023]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10023Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10025Global hot spare deleted on disk [RAID_MIB_10025]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10025Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10027Dedicated hot spare deleted on disk [RAID_MIB_10027]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10027Fujitsu.Servers.PRIMERGY.Windows.RaidManagementAvailabilityHealthFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10030Rebuild on disk failed [RAID_MIB_10030]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10030Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10031Bad block on disk detected [RAID_MIB_10031]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10031Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10033Disk removed [RAID_MIB_10033]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10033Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10036Bad sector on disk detected [RAID_MIB_10036]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10036Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10037COD I/O error on disk [RAID_MIB_10037]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10037Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10038Error on disk detected [RAID_MIB_10038]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10038Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10040Retry I/O on disk [RAID_MIB_10040]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10040Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10041ECC error on disk [RAID_MIB_10041]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10041Fujitsu.Servers.PRIMERGY.Windows.RaidManagementAvailabilityHealthTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10043Media error on disk [RAID_MIB_10043]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10043Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10044SMART Warning on disk [RAID_MIB_10044]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10044Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10045SMART error on disk [RAID_MIB_10045]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10045Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10046Bad disk inserted in enclosure [RAID_MIB_10046]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10046Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10047Enclosure powered down [RAID_MIB_10047]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10047Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10049Fan in enclosure failed [RAID_MIB_10049]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10049Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10050Temperature sensor in enclosure above threshold [RAID_MIB_10050]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10050Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10051Power supply in enclosure failed [RAID_MIB_10051]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10051Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_100523.3V power failed for disk [RAID_MIB_10052]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10052Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_100535.0V Power failed for disk [RAID_MIB_10053]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10053Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_1005412V Power failed for disk [RAID_MIB_10054]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10054Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10057Rebuild failed on logical drive [RAID_MIB_10057]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10057Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10058Rebuild aborted on logical drive [RAID_MIB_10058]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10058Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10062Consistency check failed on logical drive [RAID_MIB_10062]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10062Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10063Consistency check aborted on logical drive [RAID_MIB_10063]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10063Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10066Consistency check finished with errors on logical drive [RAID_MIB_10066]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10066Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10067Inconsistency detected on logical drive [RAID_MIB_10067]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10067Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10070Migration failed on logical drive [RAID_MIB_10070]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10070Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10071Migration aborted on logical drive [RAID_MIB_10071]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10071Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10074Patrol Read aborted [RAID_MIB_10074]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10074Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10078Logical drive degraded [RAID_MIB_10078]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10078Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10079Logical drive failed [RAID_MIB_10079]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10079Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10081Logical drive deleted [RAID_MIB_10081]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10081Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10083Logical drive error on disk [RAID_MIB_10083]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10083Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10084Logical drive bad block detected [RAID_MIB_10084]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10084Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10089BGI canceled on logical drive [RAID_MIB_10089]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10089Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10090Initialization canceled on logical drive [RAID_MIB_10090]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10090Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10093Hot spare operation on logical drive failed [RAID_MIB_10093]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10093Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10094Logical drive forced from failed to degraded [RAID_MIB_10094]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10094Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10096Alarm disabled [RAID_MIB_10096]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10096Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10139Channel disabled [RAID_MIB_10139]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10139Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10151BBU voltage problem detected [RAID_MIB_10151]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10151Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10152BBU temperature problem detected [RAID_MIB_10151]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10152Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10154BBU failed [RAID_MIB_10154]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10154Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10157Disk error fixed [RAID_MIB_10157]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10157Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10170Reboot required [RAID_MIB_10170]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10170Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10195Unable to recover cache data from TBBU [RAID_MIB_10195]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10195Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10197Cluster down; communication with peer lost [RAID_MIB_10197]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10197Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10200Controller cache discarded [RAID_MIB_10200]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10200Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10201Unable to recover cache data [RAID_MIB_10201]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10201Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10203Controller cache discarded [RAID_MIB_10203]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10203Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10204Fatal firmware error [RAID_MIB_10204]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10204Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10206Flash downloaded image corrupt [RAID_MIB_10206]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10206Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10207Flash erase error [RAID_MIB_10207]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10207Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10208Flash timeout during erase [RAID_MIB_10208]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10208Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10209Flash error [RAID_MIB_10209]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10209Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10212Flash programming error [RAID_MIB_10212]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10212Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10213Flash timeout during programming [RAID_MIB_10213]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10213Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10214Flash chip type unknown [RAID_MIB_10214]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10214Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10215Flash command set unknown [RAID_MIB_10215]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10215Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10216Flash verify failure [RAID_MIB_10216]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10216Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10221Multi-bit ECC error [RAID_MIB_10221]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10221Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10222Single-bit ECC error [RAID_MIB_10222]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10222Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10223Not enough controller memory [RAID_MIB_10223]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10223Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10231BGI finished with uncorrectable errors [RAID_MIB_10231]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10231Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10232BGI detected uncorrectable double medium errors [RAID_MIB_10232]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10232Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10233BGI failed [RAID_MIB_10233]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10233Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10237Consistency check found inconsistent parity [RAID_MIB_10237]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10237Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10240Initialization failed [RAID_MIB_10240]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10240Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10245Reconstruct detected uncorrectable double medium errors [RAID_MIB_10245]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10245Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10248Reconstruction resume failed [RAID_MIB_10248]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10248Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10250Clear aborted [RAID_MIB_10250]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10250Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10251Clear failed [RAID_MIB_10251]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10251Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10255Error on disk [RAID_MIB_10255]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10255Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10258Hot Spare SMART polling failed [RAID_MIB_10258]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10258Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10259Disk not supported [RAID_MIB_10259]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10259Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10262Patrol Read found an uncorrectable medium error [RAID_MIB_10262]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10262Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10263Predictive failure [RAID_MIB_10263]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10263Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10264Puncturing bad block [RAID_MIB_10264]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10264Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10265Rebuild aborted by user [RAID_MIB_10265]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10265Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10271Rebuild stopped [RAID_MIB_10271]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10271Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10272Reassign write operation failed [RAID_MIB_10272]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10272Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10273Unrecoverable medium error during rebuild [RAID_MIB_10273]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10273Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10275Unrecoverable medium error during recovery [RAID_MIB_10275]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10275Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10279Redundant path broken [RAID_MIB_10279]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10279Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10281Dedicated Hot Spare no longer useful [RAID_MIB_10281]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10281Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10282SAS topology error: Loop detected [RAID_MIB_10282]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10282Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10283SAS topology error: Non-addressable device [RAID_MIB_10283]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10283Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10284SAS topology error: Multiple ports to the same SAS address [RAID_MIB_10284]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10284Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10285SAS topology error: Expander error [RAID_MIB_10285]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10285Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10286SAS topology error: SMP timeout [RAID_MIB_10286]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10286Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10287SAS topology error: Out of route entries [RAID_MIB_10286]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10287Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10288SAS topology error: Index not found [RAID_MIB_10288]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10288Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10289SAS topology error: SMP function failed [RAID_MIB_10289]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10289Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10290SAS topology error: SMP CRC error [RAID_MIB_10290]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10290Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10291SAS topology error: Multiple subtractive [RAID_MIB_10291]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10291Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10292SAS topology error: Table to table [RAID_MIB_10292]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10292Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10293SAS topology error: Multiple paths [RAID_MIB_10293]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10293Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10294Unable to access disk [RAID_MIB_10294]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10294Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10295Dedicated hot spare not useful for all arrays [RAID_MIB_10295]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10295Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10296Global hot spare does not cover all arrays [RAID_MIB_10296]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10296Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10297Marking inconsistent [RAID_MIB_10297]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10297Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10303BBU has failed and cannot support data retention [RAID_MIB_10303]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10303Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10307BBU relearn timed out [RAID_MIB_10307]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10307Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10314BBU removed [RAID_MIB_10314]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10314Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10317Enclosure communication lost [RAID_MIB_10317]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10317Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10320Enclosure fan removed [RAID_MIB_10320]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10320Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10321Enclosure EMM failed [RAID_MIB_10321]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10321Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10323Enclosure EMM removed [RAID_MIB_10323]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10323Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10324Enclosure shutdown [RAID_MIB_10324]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10324Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10325Enclosure not supported; too many enclosures connected to port [RAID_MIB_10324]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10325Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10326Enclosure firmware mismatch [RAID_MIB_10325]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10326Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10327Enclosure sensor bad [RAID_MIB_10327]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10327Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10328Enclosure PHY bad [RAID_MIB_10328]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10328Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10329Enclosure is unstable [RAID_MIB_10329]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10329Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10330Enclosure hardware error [RAID_MIB_10330]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10330Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10331Enclosure not responding [RAID_MIB_10331]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10331Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10332SAS/SATA mixing not supported in enclosure [RAID_MIB_10332]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10332Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10336Disk too small to be used for auto-rebuild [RAID_MIB_10336]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10336Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10338BBU disabled; changing Write-Back virtual disks to Write-Through [RAID_MIB_10338]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10338Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10340Bad block table full [RAID_MIB_10340]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10340Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10341MDC Aborted Due to Ownership Loss [RAID_MIB_10341]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10341Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10342BGI aborted [RAID_MIB_10342]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10342Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10343BBU/charger problems detected [RAID_MIB_10343]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10343Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10344Single-bit ECC error; warning threshold exceeded [RAID_MIB_10344]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10344Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10345Single-bit ECC error; critical threshold exceeded [RAID_MIB_10345]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10345Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10346Single-bit ECC error: further reporting disabled [RAID_MIB_10346]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10346Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10347Enclosure power supply cable removed [RAID_MIB_10347]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10347Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10352BBU retention test failed [RAID_MIB_10352]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10352Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10355NVRAM retention test failed [RAID_MIB_10355]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10355Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10357Self check test failed [RAID_MIB_10357]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10357Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10362NVRAM is corrupt; reinitializing [RAID_MIB_10362]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10362Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10363NVRAM mismatch occurred [RAID_MIB_10363]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10363Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10364SAS wide port lost link on PHY [RAID_MIB_10364]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10364Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10366SAS port has exceeded the allowed error rate [RAID_MIB_10366]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10366Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10367Bad block reassigned [RAID_MIB_10367]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10367Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10376Enclosure firmware download failed [RAID_MIB_10376]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10376Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10377Disk is not certified [RAID_MIB_10377]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10377Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10378Dirty cache data discarded by user [RAID_MIB_10378]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10378Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10379PDs missing from configuration at boot [RAID_MIB_10379]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10379Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10380VDs missing drives and will go offline at boot [RAID_MIB_10380]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10380Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10381VDs missing at boot [RAID_MIB_10381]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10381Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10382Previous configuration completely missing at boot [RAID_MIB_10382]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10382Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10388Logical Drive is partially degraded [RAID_MIB_10388]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10388Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10389BBU requires reconditioning [RAID_MIB_10389]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10389Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10398MDC finished with errors on logical drive [RAID_MIB_10398]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10398Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10401Logical drive disabled because SAS drives not supported [RAID_MIB_10401]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10401Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10402Disks missing [RAID_MIB_10402]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10402Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10408MDC failed on logical drive [RAID_MIB_10408]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10408Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10409MDC aborted on logical drive [RAID_MIB_10409]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10409Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10412State change from operational to degraded [RAID_MIB_10412]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10412Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10413State change from operational to partially degraded [RAID_MIB_10413]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10413Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10414State change from operational to failed [RAID_MIB_10414]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10414Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10416State change from degraded to degraded [RAID_MIB_10416]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10416Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10417State change from degraded to partially degraded [RAID_MIB_10417]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10417Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10418State change from degraded to failed [RAID_MIB_10418]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10418Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10420State change from partially degraded to degraded [RAID_MIB_10420]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10420Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10421State change from partially degraded to partially degraded [RAID_MIB_10421]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10421Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10422State change from partially degraded to failed [RAID_MIB_10422]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10422Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10424State change from failed to degraded [RAID_MIB_10424]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10424Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10425State change from failed to partially degraded [RAID_MIB_10425]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10425Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10426State change from failed to failed [RAID_MIB_10426]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10426Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10427State change by user from available to failed [RAID_MIB_10427]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10427Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10432State change by user from failed to failed [RAID_MIB_10432]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10432Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10437State change by user from hot spare to failed [RAID_MIB_10437]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10437Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10442State change by user from rebuilding to failed [RAID_MIB_10442]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10442Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10447State change by user from operational to failed [RAID_MIB_10447]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10447Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10451State change from available to failed [RAID_MIB_10451]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10451Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10456State change from failed to failed [RAID_MIB_10456]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10456Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10461State change from hot spare to failed [RAID_MIB_10461]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10461Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10466State change from rebuilding to failed [RAID_MIB_10466]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10466Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10471State change from operational to failed [RAID_MIB_10471]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10471Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10475MDC detected uncorrectable multiple medium errors on logical drive [RAID_MIB_10475]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10475Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10476Disk missing after reboot [RAID_MIB_10476]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10476Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10477Logical drive missing after reboot [RAID_MIB_10477]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10477Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10480Puncture enabled [RAID_MIB_10480]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10480Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10481Puncture disabled [RAID_MIB_10481]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10481Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10482Enclosure EMM not installed [RAID_MIB_10482]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10482Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10485State change from available to offline [RAID_MIB_10485]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10485Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10486State change by user from available to offline [RAID_MIB_10486]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10486Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10487State change by user from failed to offline [RAID_MIB_10487]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10487Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10488State change by user from hot spare to offline [RAID_MIB_10488]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10488Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10490State change by user from offline to failed [RAID_MIB_10490]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10490Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10492State change by user from offline to offline [RAID_MIB_10492]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10492Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10495State change by user from operational to offline [RAID_MIB_10495]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10495Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10496State change by user from rebuilding to offline [RAID_MIB_10496]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10496Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10497State change from failed to offline [RAID_MIB_10497]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10497Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10498State change from hot spare to offline [RAID_MIB_10498]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10498Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10500State change from offline to failed [RAID_MIB_10500]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10500Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10502State change from offline to offline [RAID_MIB_10502]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10502Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10505State change from operational to offline [RAID_MIB_10505]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10505Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10506State change from rebuilding to offline [RAID_MIB_10506]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10506Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10508Data in cache not flushed during power up [RAID_MIB_10508]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10508Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10512Logical drive error on disk media [RAID_MIB_10512]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10512Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10514Consistency check finished with errors on logical drive [RAID_MIB_10514]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10514Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10515Error on logical drive detected [RAID_MIB_10515]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10515Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10516Disk forced from failed to online [RAID_MIB_10516]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10516Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10517Transfer speed of disk changed [RAID_MIB_10517]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10517Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10518SAS port lost link [RAID_MIB_10518]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10518Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10522Global affinity hot spare commissioned in a different enclosure [RAID_MIB_10522]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10522Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10523Foreign configuration table overflow [RAID_MIB_10523]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10523Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10524Partial foreign configuration imported [RAID_MIB_10524]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10524Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10526Adapter missing after reboot [RAID_MIB_10526]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10526Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10528Rebuild aborted on disk [RAID_MIB_10528]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10528Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10529Consistency check finished with correctable errors on logical drive [RAID_MIB_10529]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10529Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10530Consistency check finished with uncorrectable errors on logical drive [RAID_MIB_10530]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10530Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10532MDC finished with uncorrectable errors on logical drive [RAID_MIB_10532]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10532Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10534Changed adapter property detected after reboot [RAID_MIB_10534]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10534Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10536Command timeout on disk [RAID_MIB_10536]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10536Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10537Disk reset [RAID_MIB_10537]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10537Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10538Bad block table on logical drive is 80\% full [RAID_MIB_10538]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10538Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10539Bad block table on logical drive is full [RAID_MIB_10539]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10539Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10540Uncorrectable medium error logged for logical drive [RAID_MIB_10540]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10540Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10542Bad block table on disk is 100\% full [RAID_MIB_10542]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10542Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10543Bad block table on logical drive is 100\% full [RAID_MIB_10543]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10543Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10544Adapter needs replacement, faulty IOP detected [RAID_MIB_10544]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10544Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10551Copyback failed on disk [RAID_MIB_10551]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10551Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10552Early power off warning was unsuccessful [RAID_MIB_10552]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10552Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10556Foreign configuration metadata needs to be upgraded [RAID_MIB_10556]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10556Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10565Redundant path broken [RAID_MIB_10565]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10565Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10567Redundant enclosure removed [RAID_MIB_10567]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10567Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10568Patrol Read can't be started [RAID_MIB_10568]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10568Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10570Copyback aborted on hot spare [RAID_MIB_10570]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10570Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10571Copyback aborted for rebuild [RAID_MIB_10571]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10571Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10572Cache discarded for logical drive (missing or offline) [RAID_MIB_10572]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10572Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10575Redundancy building failed on disk [RAID_MIB_10575]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10575Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10576Redundancy building aborted on disk [RAID_MIB_10576]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10576Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10588Firmware update timeout on disk [RAID_MIB_10588]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10588Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10589Firmware update failed on disk [RAID_MIB_10589]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10589Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10601Periodic BBU relearn is pending [RAID_MIB_10601]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10601Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10606Disk security key, re-key operation failed [RAID_MIB_10606]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10606Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10607Disk security key is invalid [RAID_MIB_10607]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10607Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10609Disk security key from escrow is invalid [RAID_MIB_10609]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10609Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10611Logical drive is partially secured [RAID_MIB_10611]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10611Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10616Security subsystem problems detected for disk [RAID_MIB_10616]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10616Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10617Adapter cache pinned for missing or offline logical drive [RAID_MIB_10617]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10617Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10618Adapter cache pinned for missing or offline logical drives [RAID_MIB_10618]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10618Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10621MDC started on an inconsistent logical drive [RAID_MIB_10621]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10621Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10622Disk security key failure, cannot access secured configuration [RAID_MIB_10622]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10622Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10623Disk security pass phrase from user is invalid [RAID_MIB_10623]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10623Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10625Abnormal shutdown sequence detected [RAID_MIB_10625]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10625Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10626Internal hardware error [RAID_MIB_10626]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10626Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10627Internal hardware error during POST [RAID_MIB_10627]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10627Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10630Disk failed due to bad block table overflow [RAID_MIB_10630]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10630Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10631Disk failure detected during POST [RAID_MIB_10631]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10631Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10632Failure detected during POST [RAID_MIB_10632]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10632Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10633Multiple failure on disk detected [RAID_MIB_10633]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10633Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10635Disk failure detected by Patrol Read [RAID_MIB_10635]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10635Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10636Disk failure detected after successfully building redundancy [RAID_MIB_10636]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10636Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10637Disk failure detected after aborting building redundancy [RAID_MIB_10637]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10637Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10638Disk failed [RAID_MIB_10638]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10638Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10639Disk failed [RAID_MIB_10639]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10639Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10658Operation failed [RAID_MIB_10658]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10658Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10660Array without logical drive left [RAID_MIB_10660]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10660Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10661Incorrect calendar parameter detected [RAID_MIB_10661]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10661Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10662Copyback on logical drive aborted due to bad block table overflow [RAID_MIB_10662]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10662Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10663Redundant copy on logical drive aborted due to bad block table overflow [RAID_MIB_10663]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10663Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10667Bad block detected on disk [RAID_MIB_10667]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10667Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10672Error detected on disk [RAID_MIB_10672]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10672Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10675Disk location in logical drive changed [RAID_MIB_10675]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10675Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10680Driver error [RAID_MIB_10680]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10680Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10682Copyback aborted on disk [RAID_MIB_10682]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10682Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10684Internal hardware error [RAID_MIB_10684]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10684Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10685Internal hardware error [RAID_MIB_10685]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10685Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10686Disk bad block table overflow error [RAID_MIB_10686]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10686Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10687Error with the remote BBU connector cable detected [RAID_MIB_10687]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10687Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10688Multiple failure on disk detected during POST [RAID_MIB_10688]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10688Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10689Disk failed due to SAS/SATA interface error rate too high [RAID_MIB_10689]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10689Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10694Logical drive degraded due to bad block table overflow [RAID_MIB_10694]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10694Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10695Disk failed due to write error detection by driver [RAID_MIB_10695]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10695Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10696Abnormal capacity of disk in logical drive detected [RAID_MIB_10696]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10696Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10697Illegal type of disk in logical drive detected [RAID_MIB_10697]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10697Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10700Internal PCI hardware error [RAID_MIB_10700]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10700Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10701Bad block table was updated by disk [RAID_MIB_10701]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10701Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10702Invalid disk on port during start up detected [RAID_MIB_10702]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10702Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10703Invalid disk on port during hot swap detected [RAID_MIB_10703]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10703Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10704SMART error on disk because internal error threshold on adapter is exceeded [RAID_MIB_10704]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10704Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10705Firmware and driver version mismatch [RAID_MIB_10705]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10705Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10711Disk failed since it never entered ready state [RAID_MIB_10711]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10711Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10712Internal software interface error [RAID_MIB_10712]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10712Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10713Device open error [RAID_MIB_10713]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10713Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10714Ioctl send error [RAID_MIB_10714]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10714Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10715Insufficient application memory [RAID_MIB_10715]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10715Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10716System API error [RAID_MIB_10716]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10716Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10717Firmware initialization failed [RAID_MIB_10717]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10717Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10718Firmware recovery failed [RAID_MIB_10718]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10718Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10729BBU requires recalibration [RAID_MIB_10729]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10729Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10732Task for object cannot be started. The scheduler will try to start the task again later [RAID_MIB_10732]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10732Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10734Task for object cannot be started. The scheduler has disabled the task [RAID_MIB_10734]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10734Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10736SAS topology error [RAID_MIB_10736]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10736Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10737BBU requires recalibration automatically initiated [RAID_MIB_10737]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10737Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10738Task for object could not be started at the normal execution time because the service or system was down [RAID_MIB_10738]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10738Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10739Task for object cannot be started. The task will be set to the next regular execution time [RAID_MIB_10739]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10739Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10755State change from copyback to failed [RAID_MIB_10755]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10755Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10757State change from copyback to offline [RAID_MIB_10757]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10757Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10763State change from JBOD to failed [RAID_MIB_10763]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10763Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10765State change from JBOD to offline [RAID_MIB_10765]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10765Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10781State change by user from copyback to failed [RAID_MIB_10781]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10781Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10783State change by user from copyback to offline [RAID_MIB_10783]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10783Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10789State change by user from JBOD to failed [RAID_MIB_10789]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10789Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10791State change by user from JBOD to offline [RAID_MIB_10791]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10791Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10801Disk security failed to communicate with external key management system [RAID_MIB_10801]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10801Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10803Logical drive secure failed [RAID_MIB_10803]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10803Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10804Controller encountered a fatal error and was reset [RAID_MIB_10804]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10804Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10805Configuration command could not be committed to disk [RAID_MIB_10805]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10805Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10807Power state change failed on disk (from active to stopped) [RAID_MIB_10807]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10807Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10808Power state change failed on disk (from stopped to active) [RAID_MIB_10808]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10808Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10809Logical drive is not ready [RAID_MIB_10809]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10809Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10812Adapter has been replaced during reboot [RAID_MIB_10812]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10812Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10813Enclosure power supply removed [RAID_MIB_10813]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10813Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10814Enclosure power supply turned off [RAID_MIB_10814]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10814Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10817Enclosure temperature sensor below warning threshold [RAID_MIB_10817]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10817Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10818Enclosure temperature sensor below error threshold [RAID_MIB_10818]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10818Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10819Enclosure temperature sensor above warning threshold [RAID_MIB_10819]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10819Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10820Enclosure temperature sensor above error threshold [RAID_MIB_10820]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10820Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10822Power state change failed on disk (from active to transition) [RAID_MIB_10822]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10822Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10824Power state change failed on disk (from stopped to transition) [RAID_MIB_10824]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10824Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10826Power state change failed on disk (from transition to active) [RAID_MIB_10826]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10826Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10828Power state change failed on disk (from transition to stopped) [RAID_MIB_10828]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10828Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10829Reset on-board expander [RAID_MIB_10829]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10829Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10846Consistency check rejected on uninitialized logical drive [RAID_MIB_10846]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10846Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10852CacheCade(TM) capacity changed [RAID_MIB_10852]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10852Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10853BBU life has degraded and cannot initiate transparent learn cycles [RAID_MIB_10853]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10853Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10857Advanced software options serial number mismatched [RAID_MIB_10857]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10857Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10858BBU cannot support data retention [RAID_MIB_10858]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10858Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10860Logical drive cannot transition to maximum power savings [RAID_MIB_10860]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10860Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10864Disk link failed in SAS wide port [RAID_MIB_10864]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10864Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10867FBU power pack is sub-optimal [RAID_MIB_10867]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10867Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10868Foreign configuration auto-import did not import any drives [RAID_MIB_10868]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10868Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10869FBU firmware update required [RAID_MIB_10869]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10869Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10870CacheCade(TM) capacity exceeds maximum allowed size [RAID_MIB_10870]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10870Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10871Logical drive protection information lost [RAID_MIB_10871]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10871Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10873Diagnostics failed for disk [RAID_MIB_10873]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10873Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10890Erase failed on disk [RAID_MIB_10890]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10890Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10895Erase failed on logical drive [RAID_MIB_10895]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10895Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10899Potential leakage during erase on logical drive [RAID_MIB_10899]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10899Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10900BBU charging was suspended due to high BBU temperature [RAID_MIB_10900]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10900Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10902FBU firmware update failed [RAID_MIB_10902]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10902Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10903Logical drive access blocked as cached data in CacheCade(TM) is unavailable [RAID_MIB_10903]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10903Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10906CacheCade(TM) disassociate failed on logical drive [RAID_MIB_10906]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10906Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10909Unexpected sense [RAID_MIB_10909]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10909Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10910Unexpected sense [RAID_MIB_10910]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10910Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10914Advanced Software Options was deactivated for [RAID_MIB_10914]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10914Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10918Patrol Read aborted on disk [RAID_MIB_10918]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10918Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10919Transient error detected while communicating with disk [RAID_MIB_10919]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10919Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10924State change on disk from shielded to offline [RAID_MIB_10924]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10924Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10925State change on disk from shielded to failed [RAID_MIB_10925]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10925Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10931State change on disk from shielded to shielded [RAID_MIB_10931]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10931Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10932State change on disk from available to shielded [RAID_MIB_10932]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10932Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10933State change on disk from offline to shielded [RAID_MIB_10933]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10933Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10934State change on disk from failed to shielded [RAID_MIB_10934]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10934Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10935State change on disk from hot spare to shielded [RAID_MIB_10935]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10935Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10936State change on disk from rebuilding to shielded [RAID_MIB_10936]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10936Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10937State change on disk from operational to shielded [RAID_MIB_10937]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10937Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10938State change on disk from copyback to shielded [RAID_MIB_10938]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10938Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10939State change on disk from JBOD to shielded [RAID_MIB_10939]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10939Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10941State change by user on disk from shielded to offline [RAID_MIB_10941]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10941Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10942State change by user on disk from shielded to failed [RAID_MIB_10942]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10942Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10948State change by user on disk from shielded to shielded [RAID_MIB_10948]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10948Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10949State change by user on disk from available to shielded [RAID_MIB_10949]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10949Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10950State change by user on disk from offline to shielded [RAID_MIB_10950]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10950Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10951State change by user on disk from failed to shielded [RAID_MIB_10951]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10951Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10952State change by user on disk from hot spare to shielded [RAID_MIB_10952]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10952Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10953State change by user on disk from rebuilding to shielded [RAID_MIB_10953]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10953Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10954State change by user on disk from operational to shielded [RAID_MIB_10954]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10954Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10955State change by user on disk from copyback to shielded [RAID_MIB_10955]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10955Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10956State change by user on disk from JBOD to shielded [RAID_MIB_10956]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10956Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10959Write performance reduced. [RAID_MIB_10959]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10959Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10960Write operations disabled. [RAID_MIB_10960]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10960Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10961Temperature close to error threshold [RAID_MIB_10961]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10961Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10962Temperature above error threshold [RAID_MIB_10962]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10962Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10963Internal voltage out of range [RAID_MIB_10963]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10963Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10964Auxiliary voltage out of range [RAID_MIB_10964]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10964Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10965Flashback error [RAID_MIB_10965]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10965Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10966Non-correctable PCI errors detected [RAID_MIB_10966]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10966Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10967Temperature above warning threshold [RAID_MIB_10967]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10967Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10968Memory is close to wearing out [RAID_MIB_10968]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10968Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10969Non-optimal PCI slot bandwidth [RAID_MIB_10969]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10969Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10970Correctable PCI errors detected [RAID_MIB_10970]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10970Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10971Power loss protection disabled [RAID_MIB_10971]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10971Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10972Write regulation activated due to power constraints of PCI slot [RAID_MIB_10972]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10972Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10973Write regulation activated due to high temperature [RAID_MIB_10973]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10973Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10974Write regulation activated to ensure adapter lifespan [RAID_MIB_10974]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10974Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10975Running in minimal status [RAID_MIB_10975]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10975Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10976PCI power budget alarm [RAID_MIB_10976]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10976Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10977LEB map missing [RAID_MIB_10977]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10977Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10978Update in progress [RAID_MIB_10978]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10978Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10979Reserves depleted [RAID_MIB_10979]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10979Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10981Attach failed [RAID_MIB_10981]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10981Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10982Detach failed [RAID_MIB_10982]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10982Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionFalseTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10984Detached [RAID_MIB_10984]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_10984Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue
Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_4Unexpected disconnect from ServerView RAID Manager [RAID_MIB_4]Fujitsu.Servers.PRIMERGY.Windows.RAIDMIB.Alerts.RAID_MIB_4Fujitsu.Servers.PRIMERGY.Windows.RaidManagementEventCollectionTrueTrue