The drive array physical drive has degraded.
This could be caused by the following:
Physical Drive Status Changed. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current physical drive status.
If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)', or 'notAuthenticated(9)', replace the drive.
For additional troubleshooting, the following tasks are available:
HPE OneView Web Console
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Log File | Publisher | Log Message |
---|---|---|---|
3046 | HP OneView Management | HP OneView Event Manager-Server | Physical Drive Status Change (3046) Physical Drive Status Change. This trap signifies that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status. User Action: If cpaDaPhyDrvStatus is 'failed(3)', 'predictiveFailure(4)', 'ssdWearOut(8)' or 'notAuthenticated(9)', replace the drive. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Location: '%5'; Controller: '%6'; Index: '%7'; Location String: '%8'; Type: '%9'; (1=other, 2=parallelScsi, 3=sata, 4=sas) Model: '%10'; Firmware: '%11'; Serial Number: '%12'; Failure Code: '%13'; Status: '%14'; (1=other, 2=ok, 3=failed, 4=predictiveFailure, 5=erasing, 6=eraseDone, 7=eraseQueued, 8=ssdWearOut, 9=notAuthenticated) SCSI Bus Number: '%15'; [SNMP TRAP: 3046 in CPQIDA.MIB] |
See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:
HPE Microsoft Management Integration Solution
Hewlett Packard Enterprise OneView Server Management Pack
Target | HewlettPackard.Oneview.Server.HPProliantServer |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | HP OneView Management |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Physical_Drive_degraded.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="UnsignedInteger">EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="UnsignedInteger">3046</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>Drive Array Physical Drive degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>