Hewlett Packard Enterprise OneView Server Management Pack

HewlettPackard.Oneview.Server :: 3.2.0.0 (Management Pack)

Summary

Hewlett Packard Enterprise OneView Server Management Pack. This defines HPE Proliant Server Class structure and monitors. It processes monitoring of HPE Proliant Server. It relies on HPE OneView which performs base monitoring.

Related Link

HPE OneView for Microsoft System Center

PE OneView for Microsoft System Center Support

Management Pack Elements

Classes (3)

 DisplayNameIDBase ClassAbstractHostedSingletonGroupExtensionAccessibility
HewlettPackard.Oneview.Server.HPProliantServerHPE OneView Proliant ServerHewlettPackard.Oneview.Server.HPProliantServerHewlettPackard.OneView.HPLogicalHardwareFalseTrueFalseFalseFalseInternal
HewlettPackard.Oneview.Server.HPServerCollectionHPE Server CollectionHewlettPackard.Oneview.Server.HPServerCollectionHewlettPackard.OneView.HPHealthCollectionFalseTrueFalseFalseFalsePublic
HewlettPackard.Oneview.Server.HPServerGroupHPE OneView Proliant Server GroupHewlettPackard.Oneview.Server.HPServerGroupHewlettPackard.OneView.HPGroupFalseFalseTrueFalseFalsePublic

Relationship Types (3)

 DisplayNameIDSourceTargetAccessibilityAbstract
HewlettPackard.OneView.Server.HPApplianceHostingHPServersCollectionHPE OneView Appliance Hosting HPE OneView Proliant Servers CollectionHewlettPackard.OneView.Server.HPApplianceHostingHPServersCollectionHewlettPackard.OneView.ApplianceHewlettPackard.Oneview.Server.HPServerCollectionPublicFalse
HewlettPackard.OneView.Server.HPServerGroupContainsHPProliantServerHPE Server Group Contains HPE OneView Proliant ServerHewlettPackard.OneView.Server.HPServerGroupContainsHPProliantServerHewlettPackard.Oneview.Server.HPServerGroupHewlettPackard.Oneview.Server.HPProliantServerPublicFalse
HewlettPackard.OneView.Server.HPServersCollectionHostingHPProliantServerHPE Server Collection Hosting HPE OneView Proliant ServerHewlettPackard.OneView.Server.HPServersCollectionHostingHPProliantServerHewlettPackard.Oneview.Server.HPServerCollectionHewlettPackard.Oneview.Server.HPProliantServerPublicFalse

DataSource Modules (3)

 DisplayNameIDIsolationAccessibility
HewlettPackard.Oneview.Server.HPProliantServer.Discovery.DSHPE OneView Proliant Server Discovery Data SourceHewlettPackard.Oneview.Server.HPProliantServer.Discovery.DSAnyInternal
HewlettPackard.OneView.Server.HPServersCollection.Discovery.DSHPE Server Collection Discovery Data SourceHewlettPackard.OneView.Server.HPServersCollection.Discovery.DSAnyInternal
HewlettPackard.OneView.ProliantServer.UnitMonitor.DSHewlettPackard.OneView.ProliantServer.UnitMonitor.DSHewlettPackard.OneView.ProliantServer.UnitMonitor.DSAnyPublic

Unit Monitor Types (1)

 DisplayNameIDAccessibilitySupport Monitor Recalculate
HewlettPackard.OneView.ProliantServer.ResourceHealthStateHPE OneView Proliant Server Monitor TypeHewlettPackard.OneView.ProliantServer.ResourceHealthStatePublicFalse

Categories (2)

 IDTarget
HewlettPackard.Oneview.Server.HPProliantServer.iLO.Task.CategoryHewlettPackard.Oneview.Server.HPProliantServer.iLO.Task.CategoryHewlettPackard.Oneview.Server.HPProliantServer.iLO.Task
HewlettPackard.Oneview.Server.HPProliantServer.OneViewWebConsole.Task.CategoryHewlettPackard.Oneview.Server.HPProliantServer.OneViewWebConsole.Task.CategoryHewlettPackard.Oneview.Server.HPProliantServer.OneViewWebConsole.Task

Discoveries (3)

 DisplayNameIDTargetEnabled
HewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServerHPE OneView Proliant Server DiscoveryHewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServerHewlettPackard.Oneview.Server.HPServerCollectionTrue
HewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPServerCollectionHPE Server Collection DiscoveryHewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPServerCollectionHewlettPackard.OneView.ApplianceTrue
HewlettPackard.Oneview.Server.ProliantServerGroupContainsProliantServer.DiscoveryHPE OneView Proliant Server Group to Proliant Server membership discovery ruleHewlettPackard.Oneview.Server.ProliantServerGroupContainsProliantServer.DiscoveryHewlettPackard.Oneview.Server.HPServerGroupTrue

Dependency Monitors (2)

 DisplayNameIDTargetAlgorithmSource MonitorRelationshipCategoryEnabledAlert GenerateAccessibility
HewlettPackard.Oneview.Server.ProliantServerCollectionContainsProliantServerHPE OneView Proliant Server to HPE Server Collection Dependency MonitorHewlettPackard.Oneview.Server.ProliantServerCollectionContainsProliantServerHewlettPackard.Oneview.Server.HPServerCollectionWorstOfSystem.Health.AvailabilityStateHewlettPackard.OneView.Server.HPServersCollectionHostingHPProliantServerAvailabilityHealthTrueFalseInternal
HewlettPackard.Oneview.Server.ProliantServerGroupContainsProliantServerHPE OneView Proliant Server to HPE OneView Proliant Server Group Dependency MonitorHewlettPackard.Oneview.Server.ProliantServerGroupContainsProliantServerHewlettPackard.Oneview.Server.HPServerGroupWorstOfSystem.Health.AvailabilityStateHewlettPackard.OneView.Server.HPServerGroupContainsHPProliantServerAvailabilityHealthTrueFalseInternal

Unit Monitors (1)

 DisplayNameIDTargetCategoryEnabledAlert GenerateAccessibility
HewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServer.UnitMonitorHPE OneView Proliant Server Health MonitorHewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServer.UnitMonitorHewlettPackard.Oneview.Server.HPProliantServerStateCollectionTrueTrueInternal

Rules (69)

 DisplayNameIDTargetCategoryEnabledAlert Generate
HewlettPackard.Oneview.Server.HPProliantServer.ATA_RAID_Logical_Drive_degraded.RuleIDE Logical Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.ATA_RAID_Logical_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.DC_DC_power_converter_degraded_or_failed.RuleDC-DC power converter degraded or failed.HewlettPackard.Oneview.Server.HPProliantServer.DC_DC_power_converter_degraded_or_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Degraded.RuleA proliant server is in warning state.HewlettPackard.Oneview.Server.HPProliantServer.Degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Accelerator_data_degraded_or_failed.RuleDrive Array Accelerator data degraded or failed.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Accelerator_data_degraded_or_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Accelerator_degraded_or_failed_or_battery_failed.RuleDrive Array Accelerator degraded or failed or battery failed.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Accelerator_degraded_or_failed_or_battery_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Controller_degraded.RuleDrive Array Controller degraded.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Controller_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Logical_Drive_degraded.RuleDrive Array Logical Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Logical_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Physical_Drive_degraded.RuleDrive Array Physical Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Physical_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Spare_Drive_degraded.RuleDrive Array Spare Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Spare_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Tape_Drive_degraded.RuleDrive Array Tape Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Tape_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Tape_Library_door_degraded.RuleDrive Array Tape Library door degraded.HewlettPackard.Oneview.Server.HPProliantServer.Drive_Array_Tape_Library_door_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Accelerator_failed_or_data_failed_or_battery_failed.RuleExternal Array Accelerator failed or data failed or battery failed.HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Accelerator_failed_or_data_failed_or_battery_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Controller_degraded_or_failed.RuleExternal Array Controller degraded or failed.HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Controller_degraded_or_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Logical_Drive_failed.RuleExternal Array Logical Drive failed.HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Logical_Drive_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Physical_Drive_failed.RuleExternal Array Physical Drive failed.HewlettPackard.Oneview.Server.HPProliantServer.External_Array_Physical_Drive_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Tape_Drive_degraded.RuleExternal Tape Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.External_Tape_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Tape_Library_degraded.RuleExternal Tape Library degraded.HewlettPackard.Oneview.Server.HPProliantServer.External_Tape_Library_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.External_Tape_Library_door_degraded.RuleExternal Tape Library door degraded.HewlettPackard.Oneview.Server.HPProliantServer.External_Tape_Library_door_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Failed.RuleA proliant server is in critical state.HewlettPackard.Oneview.Server.HPProliantServer.Failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Fan_degraded.RuleFan degraded.HewlettPackard.Oneview.Server.HPProliantServer.Fan_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Fan_failed.RuleFan failed.HewlettPackard.Oneview.Server.HPProliantServer.Fan_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Fibre_Channel_Controller_degraded.RuleFibre Channel Controller degraded.HewlettPackard.Oneview.Server.HPProliantServer.Fibre_Channel_Controller_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.IDE_ATA_Disk_degraded.RuleIDE ATA Disk degraded.HewlettPackard.Oneview.Server.HPProliantServer.IDE_ATA_Disk_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Memory_Board_Catridge_Failed.RuleMemory Board or Cartridge is failed.HewlettPackard.Oneview.Server.HPProliantServer.Memory_Board_Catridge_Failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Memory_Board_Catridge_Removed.RuleMemory Board or Cartridge or Riser is Removed.HewlettPackard.Oneview.Server.HPProliantServer.Memory_Board_Catridge_Removed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Memory_degraded.RuleMemory degraded.HewlettPackard.Oneview.Server.HPProliantServer.Memory_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Memory_error_tracking_disabled.RuleMemory error tracking disabled.HewlettPackard.Oneview.Server.HPProliantServer.Memory_error_tracking_disabled.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Network_Interface_failed.RuleNetwork Interface failed.HewlettPackard.Oneview.Server.HPProliantServer.Network_Interface_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.NIC_Teaming_failed.RuleNIC Teaming failed.HewlettPackard.Oneview.Server.HPProliantServer.NIC_Teaming_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Power_on_self_test_degraded.RulePower-On-Self-Test degraded.HewlettPackard.Oneview.Server.HPProliantServer.Power_on_self_test_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Power_sub_system_degraded_or_failed.RulePower subsystem degraded or failed.HewlettPackard.Oneview.Server.HPProliantServer.Power_sub_system_degraded_or_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Processor_degraded.RuleProcessor degraded.HewlettPackard.Oneview.Server.HPProliantServer.Processor_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Rack_enclosure_power_subsystem_degraded.RuleRack enclosure power subsystem degraded.HewlettPackard.Oneview.Server.HPProliantServer.Rack_enclosure_power_subsystem_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Rack_power_subsystem_degraded.RuleRack power subsystem degraded.HewlettPackard.Oneview.Server.HPProliantServer.Rack_power_subsystem_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Rack_power_subsystem_not_redundant.RuleRack power subsystem not redundant.HewlettPackard.Oneview.Server.HPProliantServer.Rack_power_subsystem_not_redundant.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Rack_power_supply_failed.RuleRack power supply failed.HewlettPackard.Oneview.Server.HPProliantServer.Rack_power_supply_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Rack_server_power_subsystem_degraded.RuleRack server power subsystem degraded.HewlettPackard.Oneview.Server.HPProliantServer.Rack_server_power_subsystem_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Redundancy_Flash_Media_failed.RuleFlash media failed.HewlettPackard.Oneview.Server.HPProliantServer.Redundancy_Flash_Media_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_battery_connector_degraded.RuleRemote Management Processor battery connector degraded.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_battery_connector_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_battery_failed.RuleRemote Management Processor battery failed.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_battery_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_degraded.RuleRemote Management Processor degraded.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_failed.RuleRemote Management Processor failed.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_keyboard_connector_degraded.RuleRemote Management Processor keyboard connector degraded.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_keyboard_connector_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_mouse_connector_degraded.RuleRemote Management Processor mouse connector degraded.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_mouse_connector_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_power_connector_degraded.RuleRemote Management Processor power connector degraded.HewlettPackard.Oneview.Server.HPProliantServer.Remote_Management_Processor_power_connector_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SAS_SATA_Logical_Drive_degraded.RuleSAS/SATA Logical Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.SAS_SATA_Logical_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SAS_SATA_Physical_Drive_degraded.RuleSAS/SATA Physical Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.SAS_SATA_Physical_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SAS_Tape_Drive_degraded.RuleSAS Tape Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.SAS_Tape_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Physical_Drive_failed.RuleSCSI Physical Drive failed.HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Physical_Drive_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Drive_degraded.RuleSCSI Tape Drive degraded.HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Drive_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Drive_failed.RuleSCSI Tape Drive failed.HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Drive_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Library_failed.RuleSCSI Tape Library failed.HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Library_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Solid_State_Disk_Status_Change.RuleSolid State Disk degraded.HewlettPackard.Oneview.Server.HPProliantServer.Solid_State_Disk_Status_Change.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Connection_degraded.RuleStorage System Connection degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Connection_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Fan_degraded.RuleStorage System Fan degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Fan_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Fault_Tolerant_Power_Supply_degraded.RuleStorage System Fault Tolerant Power Supply degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Fault_Tolerant_Power_Supply_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Global_Service_Indicator.RuleStorage system Global Service Indicator Status Change.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Global_Service_Indicator.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Power_Supply_degraded.RuleStorage System Power Supply degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Power_Supply_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Power_Supply_UPS_degraded.RuleStorage System Power Supply UPS degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Power_Supply_UPS_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Recovery_Server_degraded.RuleStorage System Recovery Server degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Recovery_Server_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Side_Panel_degraded.RuleStorage System Side Panel degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Side_Panel_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Temperature_degraded.RuleStorage System Temperature degraded.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Temperature_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Temperature_failed.RuleStorage System Temperature failed.HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Temperature_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.SyncOperation_Flash_Media_failed.RuleUSB storage device sync failed.HewlettPackard.Oneview.Server.HPProliantServer.SyncOperation_Flash_Media_failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.System_Battery_Failed.RuleSystem Battery Failed.HewlettPackard.Oneview.Server.HPProliantServer.System_Battery_Failed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.System_Battery_Removed.RuleSystem Battery Removed.HewlettPackard.Oneview.Server.HPProliantServer.System_Battery_Removed.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Temperature_degraded.RuleTemperature degraded.HewlettPackard.Oneview.Server.HPProliantServer.Temperature_degraded.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Temperature_failed_and_system_shutdown.RuleTemperature failed and system shutdown.HewlettPackard.Oneview.Server.HPProliantServer.Temperature_failed_and_system_shutdown.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue
HewlettPackard.Oneview.Server.HPProliantServer.Test_Alert.RuleTest Alert.HewlettPackard.Oneview.Server.HPProliantServer.Test_Alert.RuleHewlettPackard.Oneview.Server.HPProliantServerAlertTrueTrue

Monitor Property Overrides (1)

 IDContextTarget
HewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServer.UnitMonitor.OverrideHewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServer.UnitMonitor.OverrideHewlettPackard.Oneview.Server.HPProliantServerHewlettPackard.Oneview.Server.HewlettPackard.Oneview.Server.HPProliantServer.UnitMonitor

Console Tasks (2)

 DisplayNameIDTargetAccessibilityEnabled
HewlettPackard.Oneview.Server.HPProliantServer.iLO.TaskHPE Integrated Lights-OutHewlettPackard.Oneview.Server.HPProliantServer.iLO.TaskHewlettPackard.Oneview.Server.HPProliantServerInternalTrue
HewlettPackard.Oneview.Server.HPProliantServer.OneViewWebConsole.TaskHPE OneView Web ConsoleHewlettPackard.Oneview.Server.HPProliantServer.OneViewWebConsole.TaskHewlettPackard.Oneview.Server.HPProliantServerInternalTrue

Folder Items (3)

 IDFolderNameElementID
HewlettPackard.Oneview.Server.HPServerGroupDiagramView.FolderItemHewlettPackard.Oneview.Server.HPServerGroupDiagramView.FolderItemHewlettPackard.OneView.Server.FolderHewlettPackard.Oneview.Server.HPServerGroupDiagramView
HewlettPackard.Oneview.Server.HPServersActiveAlert.FolderItemHewlettPackard.Oneview.Server.HPServersActiveAlert.FolderItemHewlettPackard.OneView.Server.FolderHewlettPackard.Oneview.Server.HPServersActiveAlert
HewlettPackard.Oneview.Server.HPServerStateView.FolderItemHewlettPackard.Oneview.Server.HPServerStateView.FolderItemHewlettPackard.OneView.Server.FolderHewlettPackard.Oneview.Server.HPServerStateView

Folders (1)

 DisplayNameIDParentFolderAccessibility
HewlettPackard.OneView.Server.FolderHPE ServersHewlettPackard.OneView.Server.FolderHewlettPackard.OneView.HPSystem.FolderPublic

Image References (3)

 DisplayNameIDImageID
HewlettPackard.Oneview.Server.HPProliantServerHPE OneView Proliant ServerHewlettPackard.Oneview.Server.HPProliantServerHewlettPackard.Oneview.Server.HPProliantServer.Big.Icon
HewlettPackard.Oneview.Server.HPServerCollectionHPE Server CollectionHewlettPackard.Oneview.Server.HPServerCollectionHewlettPackard.Oneview.Server.HPServerCollection.Big.Icon
HewlettPackard.Oneview.Server.HPServerGroupHPE OneView Proliant Server GroupHewlettPackard.Oneview.Server.HPServerGroupHewlettPackard.Oneview.Server.HPServerCollection.Big.Icon

Views (3)

 DisplayNameIDTargetTypeAccessibilityVisible
HewlettPackard.Oneview.Server.HPServerGroupDiagramViewGroup DiagramHewlettPackard.Oneview.Server.HPServerGroupDiagramViewHewlettPackard.Oneview.Server.HPServerGroupMicrosoft.SystemCenter.DiagramViewTypeInternalTrue
HewlettPackard.Oneview.Server.HPServersActiveAlertActive AlertHewlettPackard.Oneview.Server.HPServersActiveAlertHewlettPackard.Oneview.Server.HPProliantServerMicrosoft.SystemCenter.AlertViewTypeInternalTrue
HewlettPackard.Oneview.Server.HPServerStateViewHPE Server StateHewlettPackard.Oneview.Server.HPServerStateViewHewlettPackard.Oneview.Server.HPProliantServerMicrosoft.SystemCenter.StateViewTypeInternalTrue