A temperature has failed and the system will shut down.
This could be caused by the following:
The temperature status has been set to failed. The system will be shut down due to this thermal condition.
The temperature status has been set to failed in the specified chassis and location. The system will be shut down due to this condition.
None
For additional troubleshooting, the following tasks are available:
HPE OneView Web Console
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Log File | Publisher | Log Message |
---|---|---|---|
6017 | HP OneView Management | HP OneView Event Manager-Server | Thermal Failure (6017) The temperature status has been set to failed. The system will be shut down due to this thermal condition. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; [SNMP TRAP: 6017 in CPQHLTH.MIB] |
6040 | HP OneView Management | HP OneView Event Manager-Server | Thermal Failure (6040) The temperature status has been set to failed in the specified chassis and location. The system will be shut down due to this condition. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis: '%5'; Location: '%6'; (1=other, 2=unknown, 3=system, 4=systemBoard, 5=ioBoard, 6=cpu, 7=memory, 8=storage, 9=removableMedia, 10=powerSupply, 11=ambient, 12=chassis, 13=bridgeCard) [SNMP TRAP: 6040 in CPQHLTH.MIB] |
See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:
HPE Microsoft Management Integration Solution
Hewlett Packard Enterprise OneView Server Management Pack
Target | HewlettPackard.Oneview.Server.HPProliantServer |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Error |
Alert Priority | High |
Remotable | True |
Event Log | HP OneView Management |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.Temperature_failed_and_system_shutdown.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(6017|6040)$</Pattern>
</RegExExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>Temperature failed and system shutdown.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>