Rack enclosure power subsystem degraded.

HewlettPackard.Oneview.Server.HPProliantServer.Rack_enclosure_power_subsystem_degraded.Rule (Rule)

Knowledge Base article:

Summary

A rack enclosure power subsystem has degraded.

Causes

This could be caused by the following:

Resolutions

Check the server enclosure connections or add power supplies.

Check the power enclosure connections or add power supplies.

Check the enclosure and/or blade power connections and reset the fuse.

Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed.

Check the power enclosure and power supplies. Replace any failed or degraded power supplies.

Remove the extra power enclosure.

Check the cabling of the power enclosure.

For additional troubleshooting, the following tasks are available:

Related Events

The following are monitored NT Event Log entries by this rule:

Event ID

Log File

Publisher

Log Message

22024

HP OneView Management

HP OneView Event Manager-Server

Inadequate power to power on (22024) Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found. User Action: Check server enclosure connections or add power supplies. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Server Blade Enclosure Name: '%7'; Rack Server Blade Position: '%8'; Rack Server Blade Spare Part Number: '%9'; Rack Enclosure Serial Number: '%10'; Rack Enclosure Trap Sequence Number: '%11'; [SNMP TRAP: 22024 in CPQRACK.MIB]

22025

HP OneView Management

HP OneView Event Manager-Server

Inadequate power to power on (22025) Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found. User Action: Check power enclosure connections or add power supplies. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Server Blade Enclosure Name: '%7'; Rack Server Blade Position: '%8'; Rack Server Blade Spare Part Number: '%9'; Rack Enclosure Serial Number: '%10'; Rack Enclosure Trap Sequence Number: '%11'; [SNMP TRAP: 22025 in CPQRACK.MIB]

22027

HP OneView Management

HP OneView Event Manager-Server

Fuse open (22027) Fuse open. The fuse has been tripped. User Action: Check enclosure and / or blade power connections and reset the fuse. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Name: '%7'; Rack Enclosure Fuse Location: '%8'; Rack Enclosure Spare Part Number: '%9'; Rack Enclosure Serial Number: '%10'; Rack Enclosure Trap Sequence Number: '%11'; [SNMP TRAP: 22027 in CPQRACK.MIB]

22030

HP OneView Management

HP OneView Event Manager-Server

Power subsystem not load balanced (22030) Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Name: '%7'; Rack Enclosure Serial Number: '%8'; Rack Enclosure Spare Part Number: '%9'; Rack Enclosure Trap Sequence Number: '%10'; [SNMP TRAP: 22030 in CPQRACK.MIB]

22031

HP OneView Management

HP OneView Event Manager-Server

Power subsystem DC power problem (22031) Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Name: '%7'; Rack Enclosure Serial Number: '%8'; Rack Enclosure Spare Part Number: '%9'; Rack Enclosure Trap Sequence Number: '%10'; [SNMP TRAP: 22031 in CPQRACK.MIB]

22032

HP OneView Management

HP OneView Event Manager-Server

Power subsystem AC facility input power exceeded (22032) Power subsystem AC facility input power exceeded. The power subsystem AC facility input power has been exceeded for this power enclosure. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Name: '%7'; Rack Enclosure Serial Number: '%8'; Rack Enclosure Spare Part Number: '%9'; Rack Enclosure Trap Sequence Number: '%10'; [SNMP TRAP: 22032 in CPQRACK.MIB]

22033

HP OneView Management

HP OneView Event Manager-Server

Unknown power consumption (22033) Unknown power consumption. There is an unknown power consumer drawing power. User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Serial Number: '%7'; Rack Enclosure Trap Sequence Number: '%8'; [SNMP TRAP: 22033 in CPQRACK.MIB]

22035

HP OneView Management

HP OneView Event Manager-Server

Power subsystem has too many power enclosures (22035) Power subsystem has too many power enclosures. The maximum number of power enclosures has been exceeded. User Action: Remove the extra power enclosure. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Name: '%7'; Rack Enclosure Serial Number: '%8'; Rack Enclosure Trap Sequence Number: '%9'; [SNMP TRAP: 22035 in CPQRACK.MIB]

22036

HP OneView Management

HP OneView Event Manager-Server

Power subsystem improperly configured (22036) Power subsystem improperly configured. The power subsystem has been improperly configured. User Action: Check the cabling of the power enclosure. Source IP Address: '%1'; Source System GUID: '%2'; Rack Name: '%5'; Rack UID: '%6'; Rack Enclosure Name: '%7'; Rack Enclosure Serial Number: '%8'; Rack Enclosure Spare Part Number: '%9'; Rack Enclosure Trap Sequence Number: '%10'; [SNMP TRAP: 22036 in CPQRACK.MIB]

Related Links

See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:

HPE Microsoft Management Integration Solution

Management Pack Information

Hewlett Packard Enterprise OneView Server Management Pack

Element properties:

TargetHewlettPackard.Oneview.Server.HPProliantServer
CategoryAlert
EnabledTrue
Alert GenerateTrue
Alert SeverityWarning
Alert PriorityHigh
RemotableTrue
Event LogHP OneView Management

Member Modules:

ID Module Type TypeId RunAs 
DS DataSource Microsoft.Windows.EventProvider Default
GenerateAlert WriteAction System.Health.GenerateAlert Default

Source Code:

<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.Rack_enclosure_power_subsystem_degraded.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(22024|22025|22027|22030|22031|22032|22033|22035|22036)$</Pattern>
</RegExExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>Rack enclosure power subsystem degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>