A SCSI tape drive has degraded.
This could be caused by the following:
Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive heads to be cleaned.
Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape.
Clean the tape drive.
For additional troubleshooting, the following tasks are available:
HPE OneView Web Console
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Log File | Publisher | Log Message |
---|---|---|---|
5008 | HP OneView Management | HP OneView Event Manager-Server | Tape Drive Cleaning Required (5008) Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This will cause the tape drive heads to be cleaned. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Tape Physical Drive Condition: '%5'; (1=other, 2=ok, 3=degraded, 4=failed) [SNMP TRAP: 5008 in CPQSCSI.MIB] |
5009 | HP OneView Management | HP OneView Event Manager-Server | Tape Drive Cleaning Tape Needs Replacing (5009) Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Tape Physical Drive Condition: '%5'; (1=other, 2=ok, 3=degraded, 4=failed) [SNMP TRAP: 5009 in CPQSCSI.MIB] |
See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:
HPE Microsoft Management Integration Solution
Hewlett Packard Enterprise OneView Server Management Pack
Target | HewlettPackard.Oneview.Server.HPProliantServer |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | HP OneView Management |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.SCSI_Tape_Drive_degraded.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(5008|5009)$</Pattern>
</RegExExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>SCSI Tape Drive degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>