A fan has degraded.
This could be caused by the following:
The system fan status has been set to degraded. An optional system fan is not operating normally.
The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan.
The Fault Tolerant Fans have lost redundancy for the specified chassis.
Replace the fan.
For additional troubleshooting, the following tasks are available:
HPE OneView Web Console
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Log File | Publisher | Log Message |
---|---|---|---|
6021 | HP OneView Management | HP OneView Event Manager-Server | System Fan Degraded (6021) The system fan status has been set to degraded. An optional system fan is not operating normally. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; [SNMP TRAP: 6021 in CPQHLTH.MIB] |
6035 | HP OneView Management | HP OneView Event Manager-Server | Fan Degraded (6035) The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis: '%5'; Index: '%6'; [SNMP TRAP: 6035 in CPQHLTH.MIB] |
6037 | HP OneView Management | HP OneView Event Manager-Server | Fan Redundancy Lost (6037) The Fault Tolerant Fans have lost redundancy for the specified chassis. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis: '%5'; [SNMP TRAP: 6037 in CPQHLTH.MIB] |
See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:
HPE Microsoft Management Integration Solution
Hewlett Packard Enterprise OneView Server Management Pack
Target | HewlettPackard.Oneview.Server.HPProliantServer |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | HP OneView Management |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.Fan_degraded.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(6021|6035|6037)$</Pattern>
</RegExExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>Fan degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>