A storage system fan has degraded.
This could be caused by the following:
Storage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.
Storage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status.
Storage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status.
If the fan status is degraded or failed, replace any failed fans or fan modules.
For additional troubleshooting, the following tasks are available:
HPE OneView Web Console
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Log File | Publisher | Log Message |
---|---|---|---|
8008 | HP OneView Management | HP OneView Event Manager-Server | Fan Status Change (8008) Storage System fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If the fan status is degraded or failed, replace any failed fans. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Fan Status: '%5'; (1=other, 2=ok, 3=failed, 4=noFan, 5=degraded) [SNMP TRAP: 8008 in CPQSTSYS.MIB] |
8022 | HP OneView Management | HP OneView Event Manager-Server | Storage System Fan Status Change (8022) Storage system fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status. User Action: If cpqSsBackplaneFanStatus is 'degraded(4)', 'degraded-Fan1Failed(7)', 'degraded-Fan2Failed(8)' or 'failed(5)', replace the fan or fan modules. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis Name: '%5'; Chassis Time: '%6'; Backplane Index: '%7'; Backplane Vendor: '%8'; Backplane Model: '%9'; Backplane Serial Number: '%10'; Backplane Fan Status: '%11'; (1=other, 2=notInstalled, 3=ok, 4=degraded, 5=failed, 6=notSupported, 7=degraded-Fan1Failed, 8=degraded-Fan2Failed) [SNMP TRAP: 8022 in CPQSTSYS.MIB] |
8029 | HP OneView Management | HP OneView Event Manager-Server | Fan Status Change (8029) Storage System fan status change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status. User Action: If cpqSsBoxFanStatus is 'degraded(5)' or 'failed(3)', replace any failed fans or fan modules. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Controller Location: '%5'; Controller: '%6'; Bus: '%7'; Vendor: '%8'; Model: '%9'; Serial Number: '%10'; Fan Status: '%11'; (1=other, 2=ok, 3=failed, 4=noFan, 5=degraded) Location: '%12'; [SNMP TRAP: 8029 in CPQSTSYS.MIB] |
8020 | HP OneView Management | HP OneView Event Manager-Server | Fan Status Change (8020) Storage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status. User Action: If cpqSsFanModuleStatus is 'degraded(4)' or 'failed(5)', replace any failed fans or fan modules. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis Name: '%5'; Chassis Time: '%6'; Fan Module Location: '%7'; (1=other, 2=fanBay, 3=composite, 4=fanBay2) Fan Module Status: '%8'; (1=other, 2=notInstalled, 3=ok, 4=degraded, 5=failed) Fan Module Serial Number: '%9'; Fan Module Board Revision: '%10'; [SNMP TRAP: 8020 in CPQSTSYS.MIB] |
See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:
HPE Microsoft Management Integration Solution
Hewlett Packard Enterprise OneView Server Management Pack
Target | HewlettPackard.Oneview.Server.HPProliantServer |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | HP OneView Management |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Fan_degraded.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(8008|8022|8029|8020)$</Pattern>
</RegExExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>Storage System Fan degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>