A storage system power supply has degraded.
This could be caused by the following:
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status.
Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status.
If the power supply status is degraded, take action to restore power or replace the failed power supply.
For additional troubleshooting, the following tasks are available:
HPE OneView Web Console
HPE Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Log File | Publisher | Log Message |
---|---|---|---|
8024 | HP OneView Management | HP OneView Event Manager-Server | Power Supply Status Change (8024) Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status. User Action: If cpqSsBackplaneFtpsStatus is 'degraded(4)', restore power or replace the failed power supply. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis Name: '%5'; Chassis Time: '%6'; Backplane Index: '%7'; Backplane Vendor: '%8'; Backplane Model: '%9'; Backplane Serial Number: '%10'; Backplane Fault Tolerant Power Supply Status: '%11'; (1=other, 2=noFltTolPower, 3=ok, 4=degraded, 5=failed, 6=notSupported, 7=noFltTolPower-Bay1Missing, 8=noFltTolPower-Bay2Missing) [SNMP TRAP: 8024 in CPQSTSYS.MIB] |
8021 | HP OneView Management | HP OneView Event Manager-Server | Power Supply Status Change (8021) Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status. User Action: If cpqSsPowerSupplyStatus is 'failed(4)', restore power or replace the failed power supply. Source IP Address: '%1'; Source System GUID: '%2'; Server Hostname: '%3'; Chassis Name: '%5'; Chassis Time: '%6'; Power Supply Bay: '%7'; (1=other, 2=powerBay1, 3=powerBay2, 4=composite) Power Supply Status: '%8'; (1=other, 2=notInstalled, 3=ok, 4=failed, 5=degraded) Power Supply Serial Number: '%9'; Power Supply Board Revision: '%10'; Power Supply Firmware Revision: '%11'; [SNMP TRAP: 8021 in CPQSTSYS.MIB] |
See the latest information about Hewlett Packard Enterprise OneView Server Management Pack:
HPE Microsoft Management Integration Solution
Hewlett Packard Enterprise OneView Server Management Pack
Target | HewlettPackard.Oneview.Server.HPProliantServer |
Category | Alert |
Enabled | True |
Alert Generate | True |
Alert Severity | Warning |
Alert Priority | High |
Remotable | True |
Event Log | HP OneView Management |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
DS | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Oneview.Server.HPProliantServer.Storage_System_Power_Supply_degraded.Rule" Target="HewlettPackard.Oneview.Server.HPProliantServer" Enabled="true" ConfirmDelivery="false" Remotable="true" Priority="Normal" DiscardLevel="100">
<Category>Alert</Category>
<DataSources>
<DataSource ID="DS" TypeID="Windows!Microsoft.Windows.EventProvider">
<LogName>HP OneView Management</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">HP OneView Event Manager-Server</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<RegExExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>MatchesMOM2005BooleanRegularExpression</Operator>
<Pattern>^(8024|8021)$</Pattern>
</RegExExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery Type="String">Params/Param[2]</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value Type="String">$Target/Property[Type="HewlettPackard.Oneview.Server.HPProliantServer"]/ObjectID$</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="Health!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>1</Severity>
<AlertName>Storage System Power Supply degraded.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue>$Data/Params/Param[2]$</SuppressionValue>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>