External Array Accelerator failed. (consolidation)
The external array accelerator has failed. (consolidation)
This could be caused by the following:
External Array Accelerator Board Status Change. This trap signifies that the agent has detected a change in the status of a Array Accelerator Cache Board. The current status is represented by the variable cpqFcaAccelStatus.
If the accelerator board status is permDisabled(5), you might need to replace the accelerator board.
For additional troubleshooting, the following tasks are available:
HP System Management Homepage
HP Integrated Lights-Out
The following are monitored NT Event Log entries by this rule:
Event ID | Publisher | Log Message |
---|---|---|
1148 | Storage Agents | External Array Accelerator Status Change. The array accelerator board attached to the external controller in I/O slot %5 of array "%4" has a new status of %6. |
See the latest information about HP ProLiant Management Packs:
Insight Control for Microsoft System Center documentation
HP ProLiant Servers SNMP Management Pack
Target | HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerStorage |
Category | Alert |
Enabled | False |
Alert Generate | True |
Alert Severity | Error |
Alert Priority | High |
Remotable | True |
Event Log | System |
Comment | Mom2005ID='{75D8627B-4AA3-4036-A38F-730DDB0289B6}' |
ID | Module Type | TypeId | RunAs |
---|---|---|---|
_907D4578_146C_11D3_AB21_00A0C98620CE_ | DataSource | Microsoft.Windows.EventProvider | Default |
GenerateAlert | WriteAction | System.Health.GenerateAlert | Default |
<Rule ID="HewlettPackard.Servers.ProLiant.SNMP.External_Array_Accelerator_failed._5_Rule" Target="HewlettPackard.Servers.ProLiant.SNMP.HPProLiantSNMPServerStorage" Enabled="false" Comment="Mom2005ID='{75D8627B-4AA3-4036-A38F-730DDB0289B6}'">
<Category>Alert</Category>
<DataSources>
<DataSource ID="_907D4578_146C_11D3_AB21_00A0C98620CE_" Comment="{907D4578-146C-11D3-AB21-00A0C98620CE}" TypeID="Windows!Microsoft.Windows.EventProvider">
<ComputerName>$Target/Host/Host/Property[Type="Windows!Microsoft.Windows.Computer"]/PrincipalName$</ComputerName>
<LogName>System</LogName>
<Expression>
<And>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>PublisherName</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>Storage Agents</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventLevel</XPathQuery>
</ValueExpression>
<Operator>LessEqual</Operator>
<ValueExpression>
<Value>2</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
<Expression>
<SimpleExpression>
<ValueExpression>
<XPathQuery>EventDisplayNumber</XPathQuery>
</ValueExpression>
<Operator>Equal</Operator>
<ValueExpression>
<Value>1148</Value>
</ValueExpression>
</SimpleExpression>
</Expression>
</And>
</Expression>
</DataSource>
</DataSources>
<WriteActions>
<WriteAction ID="GenerateAlert" TypeID="SystemHealth!System.Health.GenerateAlert">
<Priority>2</Priority>
<Severity>2</Severity>
<AlertName>HP Windows (SNMP) External Array Accelerator failed.</AlertName>
<AlertDescription>$Data/EventDescription$</AlertDescription>
<AlertOwner/>
<Suppression>
<SuppressionValue/>
</Suppression>
</WriteAction>
</WriteActions>
</Rule>