All Unit Monitors in SCUtils.APC.PDU.MP Management Pack

 DisplayNameDescriptionIDTargetParent MonitorCategoryEnabledInstance NameCounter NameFrequencyAlert GenerateAlert SeverityAlert PriorityAlert Auto ResolveMonitor TypeRemotableAccessibilityRunAs
SCUtils.APC.PDU.Monitor.rPDULoadStatusLoadStatePDU Phase/Bank State Getting this OID will return the phase/bank load state. phaseLoadNormal(1) indicates that the phase/bank is operating properly within the rPDULoadConfigLowLoadThreshold and rPDULoadConfigNearOverloadThreshold OID values. phaseLoadLow(2) indicates that the phase/bank load has dropped below the rPDULoadConfigLowLoadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadNearOverload(3) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigNearOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. phaseLoadOverload(4) indicates that the phase/bank load is greater than or equal to the rPDULoadConfigOverloadThreshold OID value. An SNMP trap will occur when this state is entered or cleared. SCUtils.APC.PDU.Monitor.rPDULoadStatusLoadStateSCUtils.APC.PDU.PhaseBankSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU.Monitor.rPDUPowerSupplyAlarmPDU Power Supply AlarmGetting this OID will return powerSupply AlarmSCUtils.APC.PDU.Monitor.rPDUPowerSupplyAlarmSCUtils.APC.PDUSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.StatusProbeTruePublic
SCUtils.APC.PDU2.Bank.Monitor.rPDU2BankStatusLoadStatePhase Load StatusIndicates the present load status of the Rack PDU phase being queriedSCUtils.APC.PDU2.Bank.Monitor.rPDU2BankStatusLoadStateSCUtils.APC.PDU2.BankSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusLoadStatePDU Load Status Indicates the present load status of the Rack PDU SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusLoadStateSCUtils.APC.PDU2.DeviceSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply1StatusPDU Power Supply 1 AlarmGetting this OID will return power supply 1 AlarmSCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply1StatusSCUtils.APC.PDU2.DeviceSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.StatusProbeTruePublic
SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply2StatusPDU Power Supply 2 AlarmGetting this OID will return power supply 2 AlarmSCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply2StatusSCUtils.APC.PDU2.DeviceSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.StatusProbeTruePublic
SCUtils.APC.PDU2.OutletMetered.Monitor.rPDU2OutletMeteredStatusStatePhase Load StatusIndicates the present load status of the Rack PDU phase being queriedSCUtils.APC.PDU2.OutletMetered.Monitor.rPDU2OutletMeteredStatusStateSCUtils.APC.PDU2.OutletMeteredSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU2.Phase.Monitor.rPDU2PhaseStatusLoadStateBank Load StatusIndicates the present load status of the Rack PDU bank being queriedSCUtils.APC.PDU2.Phase.Monitor.rPDU2PhaseStatusLoadStateSCUtils.APC.PDU2.PhaseSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusCommStatusSensor Communication StatusThe communications status of the sensorSCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusCommStatusSCUtils.APC.PDU2.SensorSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.StatusProbeTruePublic
SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusHumidityStatusHumidity Status This OID reports the current state of the humidity probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured humidity lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured humidity lies below the low threshold. A normal (4) response indicates that the probe is present and its measured humidity lies within all humidity thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a humidity above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a humidity above the max threshold. SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusHumidityStatusSCUtils.APC.PDU2.SensorSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusTempStatusTemperature Status This OID reports the current state of the temperature probe. A notPresent (1) response indicates that no probe is attached. A belowMin (2) response indicates that the probe is present and its measured temperature lies below the minimum threshold. A belowLow (3) response indicates that the probe is present and its measured temperature lies below the low threshold. A normal (4) response indicates that the probe is present and its measured temperature lies within all temperature thresholds. An aboveHigh (5) response indicates that the probe is present and is measuring a temperature above the high threshold. An aboveMax (6) response indicates that the probe is present and is measuring a temperature above the max threshold. SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusTempStatusSCUtils.APC.PDU2.SensorSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeTruePublic
SCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusAlarmStateDiscrete Sensor Alarm StatusIndicates alarm status of discrete sensor inputSCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusAlarmStateSCUtils.APC.PDU2.SensorDiscreteSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.StatusProbeTruePublic
SCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusCommStatusDiscrete Sensor Communication StatusThe communications status of the sensorSCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusCommStatusSCUtils.APC.PDU2.SensorDiscreteSystem.Health.AvailabilityStateAvailabilityHealthTrue0TrueMatchMonitorHealthNormalTrueSCUtils.APC.PDU.MonitorType.StatusProbeTruePublic