SCUtils Management Pack for APC PDU

SCUtils.APC.PDU.MP :: 1.3.0.0 (Management Pack)

Management Pack Elements

Classes (27)

 DisplayNameIDBase ClassAbstractHostedSingletonGroupExtensionAccessibility
SCUtils.APC.PDUAPC PDUSCUtils.APC.PDUSystem.NetworkManagement.NodeFalseFalseFalseFalseFalsePublic
SCUtils.APC.PDU.AdminSettings.ActivationSCUtils Management Pack for APC PDU ActivationSCUtils.APC.PDU.AdminSettings.ActivationSCUtils.AdminSettings.BaseFalseFalseTrueFalseFalsePublic
SCUtils.APC.PDU.Devices.BankAPC PDU Devices BankSCUtils.APC.PDU.Devices.BankSCUtils.APC.PDU.LogycalDevicesTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.Devices.DeviceAPC PDU Devices DeviceSCUtils.APC.PDU.Devices.DeviceSCUtils.APC.PDU.LogycalDevicesTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.Devices.GroupAPC PDU Devices GroupSCUtils.APC.PDU.Devices.GroupSystem.GroupFalseFalseTrueTrueFalsePublic
SCUtils.APC.PDU.Devices.OutletAPC PDU Devices OutletSCUtils.APC.PDU.Devices.OutletSCUtils.APC.PDU.LogycalDevicesTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.Devices.PhaseAPC PDU Devices PhaseSCUtils.APC.PDU.Devices.PhaseSCUtils.APC.PDU.LogycalDevicesTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.Devices.PhaseBankAPC PDU Devices Phase/BankSCUtils.APC.PDU.Devices.PhaseBankSCUtils.APC.PDU.LogycalDevicesTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.Devices.SensorAPC PDU Devices SensorSCUtils.APC.PDU.Devices.SensorSystem.NetworkManagement.NumericSensorTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.LogycalDevicesAPC PDU Logycal DevicesSCUtils.APC.PDU.LogycalDevicesSystem.NetworkManagement.LogicalDeviceTrueFalseFalseFalseFalsePublic
SCUtils.APC.PDU.OutletPDU Outlet LoadSCUtils.APC.PDU.OutletSCUtils.APC.PDU.Devices.OutletFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU.OutletsPDU OutletsSCUtils.APC.PDU.OutletsSystem.LogicalEntityFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU.PhaseBankPDU Phase/BankSCUtils.APC.PDU.PhaseBankSCUtils.APC.PDU.Devices.PhaseBankFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU.PhasesPDU Phases/BanksSCUtils.APC.PDU.PhasesSystem.LogicalEntityFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2APC PDU2SCUtils.APC.PDU2System.NetworkManagement.NodeFalseFalseFalseFalseFalsePublic
SCUtils.APC.PDU2.BankPDU BankSCUtils.APC.PDU2.BankSCUtils.APC.PDU.Devices.BankFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.BanksPDU BanksSCUtils.APC.PDU2.BanksSystem.LogicalEntityFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.DeviceAPC PDU2 DeviceSCUtils.APC.PDU2.DeviceSCUtils.APC.PDU.Devices.DeviceFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.DevicesAPC PDU2 DevicesSCUtils.APC.PDU2.DevicesSystem.LogicalEntityFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.OutletMeteredPDU Outlet MeteredSCUtils.APC.PDU2.OutletMeteredSCUtils.APC.PDU.Devices.OutletFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.OutletsPDU OutletsSCUtils.APC.PDU2.OutletsSystem.LogicalEntityFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.OutletSwitchedPDU Outlet SwitchedSCUtils.APC.PDU2.OutletSwitchedSCUtils.APC.PDU.Devices.OutletFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.PhasePDU PhaseSCUtils.APC.PDU2.PhaseSCUtils.APC.PDU.Devices.PhaseFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.PhasesPDU PhasesSCUtils.APC.PDU2.PhasesSystem.LogicalEntityFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.SensorPDU SensorSCUtils.APC.PDU2.SensorSCUtils.APC.PDU.Devices.SensorFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.SensorDiscretePDU Discrete SensorSCUtils.APC.PDU2.SensorDiscreteSCUtils.APC.PDU.Devices.SensorFalseTrueFalseFalseFalsePublic
SCUtils.APC.PDU2.SensorsPDU SensorsSCUtils.APC.PDU2.SensorsSystem.LogicalEntityFalseTrueFalseFalseFalsePublic

Relationship Types (18)

 DisplayNameIDSourceTargetAccessibilityAbstract
SCUtils.APC.PDU.Relationship.DevicesGroupContains.APC.PDUAPC PDU Devices Group Contains APC PDUSCUtils.APC.PDU.Relationship.DevicesGroupContains.APC.PDUSCUtils.APC.PDU.Devices.GroupSCUtils.APC.PDUPublicFalse
SCUtils.APC.PDU.Relationship.DevicesGroupContains.APC.PDU2APC PDU Devices Group Contains APC PDU2SCUtils.APC.PDU.Relationship.DevicesGroupContains.APC.PDU2SCUtils.APC.PDU.Devices.GroupSCUtils.APC.PDU2PublicFalse
SCUtils.APC.PDU.Relationship.Host.APC.PDU.OutletsAPC PDU Host OutletsSCUtils.APC.PDU.Relationship.Host.APC.PDU.OutletsSCUtils.APC.PDUSCUtils.APC.PDU.OutletsPublicFalse
SCUtils.APC.PDU.Relationship.Host.APC.PDU.PhasesAPC PDU Host PhasesSCUtils.APC.PDU.Relationship.Host.APC.PDU.PhasesSCUtils.APC.PDUSCUtils.APC.PDU.PhasesPublicFalse
SCUtils.APC.PDU.Relationship.Outlets.Host.APC.PDU.OutletAPC PDU Outlets Host Outlet LoadSCUtils.APC.PDU.Relationship.Outlets.Host.APC.PDU.OutletSCUtils.APC.PDU.OutletsSCUtils.APC.PDU.OutletPublicFalse
SCUtils.APC.PDU.Relationship.Phases.Host.APC.PDU.PhaseBankAPC PDU Phases Host Phase LoadSCUtils.APC.PDU.Relationship.Phases.Host.APC.PDU.PhaseBankSCUtils.APC.PDU.PhasesSCUtils.APC.PDU.PhaseBankPublicFalse
SCUtils.APC.PDU2.Relationship.Banks.Host.APC.PDU2.BankBanks Host APC PDU2 BankSCUtils.APC.PDU2.Relationship.Banks.Host.APC.PDU2.BankSCUtils.APC.PDU2.BanksSCUtils.APC.PDU2.BankPublicFalse
SCUtils.APC.PDU2.Relationship.Devices.Host.APC.PDU2.DeviceAPC PDU Devices Host APC PDU2 DeviceSCUtils.APC.PDU2.Relationship.Devices.Host.APC.PDU2.DeviceSCUtils.APC.PDU2.DevicesSCUtils.APC.PDU2.DevicePublicFalse
SCUtils.APC.PDU2.Relationship.Host.APC.PDU2.BanksAPC PDU2 Host APC PDU2 BanksSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.BanksSCUtils.APC.PDU2SCUtils.APC.PDU2.BanksPublicFalse
SCUtils.APC.PDU2.Relationship.Host.APC.PDU2.DevicesAPC PDU2 Host PDU2 DevicesSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.DevicesSCUtils.APC.PDU2SCUtils.APC.PDU2.DevicesPublicFalse
SCUtils.APC.PDU2.Relationship.Host.APC.PDU2.OutletsAPC PDU2 Host APC PDU2 OutletsSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.OutletsSCUtils.APC.PDU2SCUtils.APC.PDU2.OutletsPublicFalse
SCUtils.APC.PDU2.Relationship.Host.APC.PDU2.PhasesAPC PDU2 Host APC PDU2 PhasesSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.PhasesSCUtils.APC.PDU2SCUtils.APC.PDU2.PhasesPublicFalse
SCUtils.APC.PDU2.Relationship.Host.APC.PDU2.SensorsAPC PDU2 Host APC PDU2 SensorsSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.SensorsSCUtils.APC.PDU2SCUtils.APC.PDU2.SensorsPublicFalse
SCUtils.APC.PDU2.Relationship.Outlets.Host.APC.PDU2.OutletMeteredOutlets Host APC PDU2 Outlet MeteredSCUtils.APC.PDU2.Relationship.Outlets.Host.APC.PDU2.OutletMeteredSCUtils.APC.PDU2.OutletsSCUtils.APC.PDU2.OutletMeteredPublicFalse
SCUtils.APC.PDU2.Relationship.Outlets.Host.APC.PDU2.OutletSwitchedOutlets Host APC PDU2 Outlet SwitchedSCUtils.APC.PDU2.Relationship.Outlets.Host.APC.PDU2.OutletSwitchedSCUtils.APC.PDU2.OutletsSCUtils.APC.PDU2.OutletSwitchedPublicFalse
SCUtils.APC.PDU2.Relationship.Phases.Host.APC.PDU2.PhasePhases Host APC PDU2 PhaseSCUtils.APC.PDU2.Relationship.Phases.Host.APC.PDU2.PhaseSCUtils.APC.PDU2.PhasesSCUtils.APC.PDU2.PhasePublicFalse
SCUtils.APC.PDU2.Relationship.Sensors.Host.APC.PDU2.SensorSensors Host APC PDU2 SensorSCUtils.APC.PDU2.Relationship.Sensors.Host.APC.PDU2.SensorSCUtils.APC.PDU2.SensorsSCUtils.APC.PDU2.SensorPublicFalse
SCUtils.APC.PDU2.Relationship.Sensors.Host.APC.PDU2.SensorDiscreteSensors Host APC PDU2 SensorDiscreteSCUtils.APC.PDU2.Relationship.Sensors.Host.APC.PDU2.SensorDiscreteSCUtils.APC.PDU2.SensorsSCUtils.APC.PDU2.SensorDiscretePublicFalse

ConditionDetection Modules (1)

 IDIsolationAccessibility
SCUtils.APC.PDU.DS.Transponder.CDSCUtils.APC.PDU.DS.Transponder.CDAnyPublic

DataSource Modules (17)

 IDIsolationAccessibility
SCUtils.APC.PDU.Advanced.SnmpProbe.DSSCUtils.APC.PDU.Advanced.SnmpProbe.DSAnyPublic
SCUtils.APC.PDU.BasicSnmpProbe.DSSCUtils.APC.PDU.BasicSnmpProbe.DSAnyPublic
SCUtils.APC.PDU.Device.Details.Discovery.DSSCUtils.APC.PDU.Device.Details.Discovery.DSAnyInternal
SCUtils.APC.PDU.Device.Discovery.DSSCUtils.APC.PDU.Device.Discovery.DSAnyInternal
SCUtils.APC.PDU.DiscoverObject.DSSCUtils.APC.PDU.DiscoverObject.DSAnyPublic
SCUtils.APC.PDU.DiscoverProperties.DSSCUtils.APC.PDU.DiscoverProperties.DSAnyPublic
SCUtils.APC.PDU.DiscoverSubSystem.DSSCUtils.APC.PDU.DiscoverSubSystem.DSAnyPublic
SCUtils.APC.PDU.DiscoverySnmpProbe.DSSCUtils.APC.PDU.DiscoverySnmpProbe.DSAnyPublic
SCUtils.APC.PDU.DiscoveryWalkSnmpProbe.DSSCUtils.APC.PDU.DiscoveryWalkSnmpProbe.DSAnyPublic
SCUtils.APC.PDU.LicenseCheck.DSSCUtils.APC.PDU.LicenseCheck.DSAnyPublic
SCUtils.APC.PDU.Outlet.Convert.Mapped.DSSCUtils.APC.PDU.Outlet.Convert.Mapped.DSAnyPublic
SCUtils.APC.PDU.PhaseBank.DivisionTo10.DSSCUtils.APC.PDU.PhaseBank.DivisionTo10.DSAnyInternal
SCUtils.APC.PDU.PhaseBank.DivisionTo100.DSSCUtils.APC.PDU.PhaseBank.DivisionTo100.DSAnyInternal
SCUtils.APC.PDU2.Device.Details.Discovery.DSSCUtils.APC.PDU2.Device.Details.Discovery.DSAnyInternal
SCUtils.APC.PDU2.OutletSwitched.Convert.Mapped.DSSCUtils.APC.PDU2.OutletSwitched.Convert.Mapped.DSAnyPublic
SCUtils.APC.PDU2.Sensor.Convert.Mapped.DSSCUtils.APC.PDU2.Sensor.Convert.Mapped.DSAnyPublic
SCUtils.APC.PDU2.SensorDiscrete.Convert.Mapped.DSSCUtils.APC.PDU2.SensorDiscrete.Convert.Mapped.DSAnyPublic

ProbeAction Modules (8)

 IDIsolationAccessibility
SCUtils.APC.PDU.Device.Activate.PASCUtils.APC.PDU.Device.Activate.PAAnyPublic
SCUtils.APC.PDU.Device.CheckLicense.PASCUtils.APC.PDU.Device.CheckLicense.PAAnyPublic
SCUtils.APC.PDU.Device.Division.PASCUtils.APC.PDU.Device.Division.PAAnyPublic
SCUtils.APC.PDU.Device.DoubleTextConverter.PASCUtils.APC.PDU.Device.DoubleTextConverter.PAAnyPublic
SCUtils.APC.PDU.Device.GetUniqueID.PASCUtils.APC.PDU.Device.GetUniqueID.PAAnyPublic
SCUtils.APC.PDU.Device.Indexer.ProveAction.MTSCUtils.APC.PDU.Device.Indexer.ProveAction.MTAnyPublic
SCUtils.APC.PDU.Device.Matcher.ProveAction.MTSCUtils.APC.PDU.Device.Matcher.ProveAction.MTAnyPublic
SCUtils.APC.PDU.Device.SingleTextConverter.PASCUtils.APC.PDU.Device.SingleTextConverter.PAAnyPublic

WriteAction Modules (1)

 IDIsolationAccessibility
SCUtils.APC.PDU.Device.Disposal.WASCUtils.APC.PDU.Device.Disposal.WAAnyPublic

Unit Monitor Types (4)

 IDAccessibilitySupport Monitor Recalculate
SCUtils.APC.PDU.MonitorType.Advanced.StatusProbeSCUtils.APC.PDU.MonitorType.Advanced.StatusProbePublicFalse
SCUtils.APC.PDU.MonitorType.Advanced.ThreeLevel.StatusProbeSCUtils.APC.PDU.MonitorType.Advanced.ThreeLevel.StatusProbePublicFalse
SCUtils.APC.PDU.MonitorType.StatusProbeSCUtils.APC.PDU.MonitorType.StatusProbePublicFalse
SCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbeSCUtils.APC.PDU.MonitorType.ThreeLevel.StatusProbePublicFalse

Categories (4)

 IDTarget
SCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.Http.CategorySCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.Http.CategorySCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.Http
SCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.Https.CategorySCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.Https.CategorySCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.Https
SCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.Http.CategorySCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.Http.CategorySCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.Http
SCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.Https.CategorySCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.Https.CategorySCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.Https

Discoveries (35)

 DisplayNameIDTargetEnabled
SCUtils.APC.PDU.Details.DiscoveryAPC PDU Details DiscoverySCUtils.APC.PDU.Details.DiscoverySCUtils.APC.PDUTrue
SCUtils.APC.PDU.Devices.Group.DiscoveryAPC PDU Devices Group DiscoverySCUtils.APC.PDU.Devices.Group.DiscoverySCUtils.APC.PDU.Devices.GroupTrue
SCUtils.APC.PDU.DiscoveryAPC PDU DiscoverySCUtils.APC.PDU.DiscoverySystem.NetworkManagement.NodeTrue
SCUtils.APC.PDU.Outlet.Convert.Mapped.DiscoveryAPC PDU Outlet Convert Properties DiscoverySCUtils.APC.PDU.Outlet.Convert.Mapped.DiscoverySCUtils.APC.PDU.OutletTrue
SCUtils.APC.PDU.Outlet.Index.DiscoveryAPC PDU Outlet Index DiscoverySCUtils.APC.PDU.Outlet.Index.DiscoverySCUtils.APC.PDU.OutletsTrue
SCUtils.APC.PDU.Outlet.Properties.DiscoveryAPC PDU Outlet Properties DiscoverySCUtils.APC.PDU.Outlet.Properties.DiscoverySCUtils.APC.PDU.OutletTrue
SCUtils.APC.PDU.Outlets.DiscoveryAPC PDU Outlets DiscoverySCUtils.APC.PDU.Outlets.DiscoverySCUtils.APC.PDUTrue
SCUtils.APC.PDU.PhaseBank.Index.DiscoveryAPC PDU Phase/Bank Index DiscoverySCUtils.APC.PDU.PhaseBank.Index.DiscoverySCUtils.APC.PDU.PhasesTrue
SCUtils.APC.PDU.PhaseBank.Properties.DiscoveryAPC PDU Phase/Bank Properties DiscoverySCUtils.APC.PDU.PhaseBank.Properties.DiscoverySCUtils.APC.PDU.PhaseBankTrue
SCUtils.APC.PDU.Phases.DiscoveryAPC PDU Phases DiscoverySCUtils.APC.PDU.Phases.DiscoverySCUtils.APC.PDUTrue
SCUtils.APC.PDU2.Bank.Properties.DiscoveryAPC PDU2 Bank Properties DiscoverySCUtils.APC.PDU2.Bank.Properties.DiscoverySCUtils.APC.PDU2.BankTrue
SCUtils.APC.PDU2.Bank.Properties.Index.DiscoveryAPC PDU2 Bank Properties Index DiscoverySCUtils.APC.PDU2.Bank.Properties.Index.DiscoverySCUtils.APC.PDU2.BanksTrue
SCUtils.APC.PDU2.Banks.DiscoveryAPC PDU2 Banks DiscoverySCUtils.APC.PDU2.Banks.DiscoverySCUtils.APC.PDU2True
SCUtils.APC.PDU2.Details.DiscoveryAPC PDU2 Details DiscoverySCUtils.APC.PDU2.Details.DiscoverySCUtils.APC.PDU2True
SCUtils.APC.PDU2.Device.Properties.DiscoveryAPC PDU2 Device Properties DiscoverySCUtils.APC.PDU2.Device.Properties.DiscoverySCUtils.APC.PDU2.DeviceTrue
SCUtils.APC.PDU2.Device.Properties.Index.DiscoveryAPC PDU2 Device Properties Index DiscoverySCUtils.APC.PDU2.Device.Properties.Index.DiscoverySCUtils.APC.PDU2.DevicesTrue
SCUtils.APC.PDU2.Devices.DiscoveryAPC PDU2 Devices DiscoverySCUtils.APC.PDU2.Devices.DiscoverySCUtils.APC.PDU2True
SCUtils.APC.PDU2.Devices.Group.DiscoveryAPC PDU2 Devices Group DiscoverySCUtils.APC.PDU2.Devices.Group.DiscoverySCUtils.APC.PDU.Devices.GroupTrue
SCUtils.APC.PDU2.DiscoveryAPC PDU2 DiscoverySCUtils.APC.PDU2.DiscoverySystem.NetworkManagement.NodeTrue
SCUtils.APC.PDU2.OutletMetered.Properties.DiscoveryAPC PDU2 Metered Outlet Properties DiscoverySCUtils.APC.PDU2.OutletMetered.Properties.DiscoverySCUtils.APC.PDU2.OutletMeteredTrue
SCUtils.APC.PDU2.OutletMetered.Properties.Index.DiscoveryAPC PDU2 Metered Outlet Properties Index DiscoverySCUtils.APC.PDU2.OutletMetered.Properties.Index.DiscoverySCUtils.APC.PDU2.OutletsTrue
SCUtils.APC.PDU2.Outlets.DiscoveryAPC PDU2 Outlets DiscoverySCUtils.APC.PDU2.Outlets.DiscoverySCUtils.APC.PDU2True
SCUtils.APC.PDU2.OutletSwitched.Convert.Mapped.DiscoveryAPC PDU2 Switched Outlet Convert Number to String DiscoverySCUtils.APC.PDU2.OutletSwitched.Convert.Mapped.DiscoverySCUtils.APC.PDU2.OutletSwitchedTrue
SCUtils.APC.PDU2.OutletSwitched.Properties.DiscoveryAPC PDU2 Switched Outlet Properties DiscoverySCUtils.APC.PDU2.OutletSwitched.Properties.DiscoverySCUtils.APC.PDU2.OutletSwitchedTrue
SCUtils.APC.PDU2.OutletSwitched.Properties.Index.DiscoveryAPC PDU2 Switched Outlet Properties Index DiscoverySCUtils.APC.PDU2.OutletSwitched.Properties.Index.DiscoverySCUtils.APC.PDU2.OutletsTrue
SCUtils.APC.PDU2.Phase.Properties.DiscoveryAPC PDU2 Phase Properties DiscoverySCUtils.APC.PDU2.Phase.Properties.DiscoverySCUtils.APC.PDU2.PhaseTrue
SCUtils.APC.PDU2.Phase.Properties.Index.DiscoveryAPC PDU2 Phase Properties Index DiscoverySCUtils.APC.PDU2.Phase.Properties.Index.DiscoverySCUtils.APC.PDU2.PhasesTrue
SCUtils.APC.PDU2.Phases.DiscoveryAPC PDU2 Phases DiscoverySCUtils.APC.PDU2.Phases.DiscoverySCUtils.APC.PDU2True
SCUtils.APC.PDU2.Sensor.Convert.Mapped.DiscoveryAPC PDU2 Sensor Convert Number to String DiscoverySCUtils.APC.PDU2.Sensor.Convert.Mapped.DiscoverySCUtils.APC.PDU2.SensorTrue
SCUtils.APC.PDU2.Sensor.Properties.DiscoveryAPC PDU2 Sensor Properties DiscoverySCUtils.APC.PDU2.Sensor.Properties.DiscoverySCUtils.APC.PDU2.SensorTrue
SCUtils.APC.PDU2.Sensor.Properties.Index.DiscoveryAPC PDU2 Sensor Properties Index DiscoverySCUtils.APC.PDU2.Sensor.Properties.Index.DiscoverySCUtils.APC.PDU2.SensorsTrue
SCUtils.APC.PDU2.SensorDiscrete.Convert.Mapped.DiscoveryAPC PDU2 Discrete Sensor Convert Number to String DiscoverySCUtils.APC.PDU2.SensorDiscrete.Convert.Mapped.DiscoverySCUtils.APC.PDU2.SensorDiscreteTrue
SCUtils.APC.PDU2.SensorDiscrete.Properties.DiscoveryAPC PDU2 Discrete Sensor Properties DiscoverySCUtils.APC.PDU2.SensorDiscrete.Properties.DiscoverySCUtils.APC.PDU2.SensorDiscreteTrue
SCUtils.APC.PDU2.SensorDiscrete.Properties.Index.DiscoveryAPC PDU2 Discrete Sensor Properties Index DiscoverySCUtils.APC.PDU2.SensorDiscrete.Properties.Index.DiscoverySCUtils.APC.PDU2.SensorsTrue
SCUtils.APC.PDU2.Sensors.DiscoveryAPC PDU2 Sensors DiscoverySCUtils.APC.PDU2.Sensors.DiscoverySCUtils.APC.PDU2True

Dependency Monitors (18)

 DisplayNameIDTargetAlgorithmSource MonitorRelationshipCategoryEnabledAlert GenerateAccessibility
SCUtils.APC.PDU.Monitor.APCPDUDependsOn.APC.PDU.Outlets.AvailabilityPDU OutletsSCUtils.APC.PDU.Monitor.APCPDUDependsOn.APC.PDU.Outlets.AvailabilitySCUtils.APC.PDUWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU.Relationship.Host.APC.PDU.OutletsAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU.Monitor.APCPDUDependsOn.APC.PDU.Phases.AvailabilityPDU Phases/BanksSCUtils.APC.PDU.Monitor.APCPDUDependsOn.APC.PDU.Phases.AvailabilitySCUtils.APC.PDUWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU.Relationship.Host.APC.PDU.PhasesAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU.Monitor.GroupContains.APC.PDUAPC PDU DevicesSCUtils.APC.PDU.Monitor.GroupContains.APC.PDUSCUtils.APC.PDU.Devices.GroupWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU.Relationship.DevicesGroupContains.APC.PDUAvailabilityHealthTrueFalseInternal
SCUtils.APC.PDU.Monitor.GroupContains.APC.PDU2APC PDU2SCUtils.APC.PDU.Monitor.GroupContains.APC.PDU2SCUtils.APC.PDU.Devices.GroupWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU.Relationship.DevicesGroupContains.APC.PDU2AvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU.Monitor.OutletsDependsOn.APC.PDU.Outlet.AvailabilityPDU OutletSCUtils.APC.PDU.Monitor.OutletsDependsOn.APC.PDU.Outlet.AvailabilitySCUtils.APC.PDU.OutletsWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU.Relationship.Outlets.Host.APC.PDU.OutletAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU.Monitor.PhasesDependsOn.APC.PDU.PhaseBank.AvailabilityPDU Phase/BankSCUtils.APC.PDU.Monitor.PhasesDependsOn.APC.PDU.PhaseBank.AvailabilitySCUtils.APC.PDU.PhasesWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU.Relationship.Phases.Host.APC.PDU.PhaseBankAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Banks.AvailabilityPDU2 BanksSCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Banks.AvailabilitySCUtils.APC.PDU2WorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.BanksAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Devices.AvailabilityAPC PDU2 DevicesSCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Devices.AvailabilitySCUtils.APC.PDU2WorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.DevicesAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Outlets.AvailabilityPDU2 OutletsSCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Outlets.AvailabilitySCUtils.APC.PDU2WorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.OutletsAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Phases.AvailabilityPDU2 PhasesSCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Phases.AvailabilitySCUtils.APC.PDU2WorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.PhasesAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Sensors.AvailabilityPDU2 SensorsSCUtils.APC.PDU2.Monitor.APCPDUDependsOn.APC.PDU2.Sensors.AvailabilitySCUtils.APC.PDU2WorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Host.APC.PDU2.SensorsAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.BanksDependsOn.APC.PDU2.Bank.AvailabilityPDU2 BankSCUtils.APC.PDU2.Monitor.BanksDependsOn.APC.PDU2.Bank.AvailabilitySCUtils.APC.PDU2.BanksWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Banks.Host.APC.PDU2.BankAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.DevicesDependsOn.APC.PDU2.Device.AvailabilityAPC PDU2 DeviceSCUtils.APC.PDU2.Monitor.DevicesDependsOn.APC.PDU2.Device.AvailabilitySCUtils.APC.PDU2.DevicesWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Devices.Host.APC.PDU2.DeviceAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.OutletsDependsOn.APC.PDU2.OutletMetered.AvailabilityPDU2 Metered OutletSCUtils.APC.PDU2.Monitor.OutletsDependsOn.APC.PDU2.OutletMetered.AvailabilitySCUtils.APC.PDU2.OutletsWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Outlets.Host.APC.PDU2.OutletMeteredAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.OutletsDependsOn.APC.PDU2.OutletSwitched.AvailabilityPDU2 Switched OutletSCUtils.APC.PDU2.Monitor.OutletsDependsOn.APC.PDU2.OutletSwitched.AvailabilitySCUtils.APC.PDU2.OutletsWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Outlets.Host.APC.PDU2.OutletSwitchedAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.PhasesDependsOn.APC.PDU2.Phase.AvailabilityPDU2 PhaseSCUtils.APC.PDU2.Monitor.PhasesDependsOn.APC.PDU2.Phase.AvailabilitySCUtils.APC.PDU2.PhasesWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Phases.Host.APC.PDU2.PhaseAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.SensorsDependsOn.APC.PDU2.Sensor.AvailabilityPDU2 SensorSCUtils.APC.PDU2.Monitor.SensorsDependsOn.APC.PDU2.Sensor.AvailabilitySCUtils.APC.PDU2.SensorsWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Sensors.Host.APC.PDU2.SensorAvailabilityHealthTrueFalsePublic
SCUtils.APC.PDU2.Monitor.SensorsDependsOn.APC.PDU2.SensorDiscrete.AvailabilityPDU2 Discrete SensorSCUtils.APC.PDU2.Monitor.SensorsDependsOn.APC.PDU2.SensorDiscrete.AvailabilitySCUtils.APC.PDU2.SensorsWorstOfSystem.Health.AvailabilityStateSCUtils.APC.PDU2.Relationship.Sensors.Host.APC.PDU2.SensorDiscreteAvailabilityHealthTrueFalsePublic

Unit Monitors (13)

 DisplayNameIDTargetCategoryEnabledAlert GenerateAccessibility
SCUtils.APC.PDU.Monitor.rPDULoadStatusLoadStatePDU Phase/Bank StateSCUtils.APC.PDU.Monitor.rPDULoadStatusLoadStateSCUtils.APC.PDU.PhaseBankAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU.Monitor.rPDUPowerSupplyAlarmPDU Power Supply AlarmSCUtils.APC.PDU.Monitor.rPDUPowerSupplyAlarmSCUtils.APC.PDUAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Bank.Monitor.rPDU2BankStatusLoadStatePhase Load StatusSCUtils.APC.PDU2.Bank.Monitor.rPDU2BankStatusLoadStateSCUtils.APC.PDU2.BankAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusLoadStatePDU Load StatusSCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusLoadStateSCUtils.APC.PDU2.DeviceAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply1StatusPDU Power Supply 1 AlarmSCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply1StatusSCUtils.APC.PDU2.DeviceAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply2StatusPDU Power Supply 2 AlarmSCUtils.APC.PDU2.Device.Monitor.rPDU2DeviceStatusPowerSupply2StatusSCUtils.APC.PDU2.DeviceAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.OutletMetered.Monitor.rPDU2OutletMeteredStatusStatePhase Load StatusSCUtils.APC.PDU2.OutletMetered.Monitor.rPDU2OutletMeteredStatusStateSCUtils.APC.PDU2.OutletMeteredAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Phase.Monitor.rPDU2PhaseStatusLoadStateBank Load StatusSCUtils.APC.PDU2.Phase.Monitor.rPDU2PhaseStatusLoadStateSCUtils.APC.PDU2.PhaseAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusCommStatusSensor Communication StatusSCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusCommStatusSCUtils.APC.PDU2.SensorAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusHumidityStatusHumidity StatusSCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusHumidityStatusSCUtils.APC.PDU2.SensorAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusTempStatusTemperature StatusSCUtils.APC.PDU2.Sensor.Monitor.rPDU2SensorTempHumidityStatusTempStatusSCUtils.APC.PDU2.SensorAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusAlarmStateDiscrete Sensor Alarm StatusSCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusAlarmStateSCUtils.APC.PDU2.SensorDiscreteAvailabilityHealthTrueTruePublic
SCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusCommStatusDiscrete Sensor Communication StatusSCUtils.APC.PDU2.SensorDiscrete.Monitor.rPDU2SensorDiscreteStatusCommStatusSCUtils.APC.PDU2.SensorDiscreteAvailabilityHealthTrueTruePublic

Rules (190)

 DisplayNameIDTargetCategoryEnabledAlert Generate
SCUtils.APC.PDU.LicenseCheck.RuleSCUtils Management Pack for APC PDU License Check RuleSCUtils.APC.PDU.LicenseCheck.RuleSCUtils.APC.PDU.Devices.GroupAlertTrueTrue
SCUtils.APC.PDU.Rule.accessViolationConsolePDU Trap Alert Rule - Someone has attempted to login via the console with the incorrect passwordSCUtils.APC.PDU.Rule.accessViolationConsoleSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.accessViolationHTTPPDU Trap Alert Rule - Someone has attempted to login via HTTP with the incorrect passwordSCUtils.APC.PDU.Rule.accessViolationHTTPSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.apcTestTrapPDU Trap Alert Rule - Trap used to test SNMP trap functionalitySCUtils.APC.PDU.Rule.apcTestTrapSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.configChangeOutletPDU Trap Alert Rule - The specified PDU outlet has changed configuration.SCUtils.APC.PDU.Rule.configChangeOutletSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.configChangeSNMPPDU Trap Alert Rule - The SNMP configuration has been changedSCUtils.APC.PDU.Rule.configChangeSNMPSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.DisposalAPC PDU Disposal RuleSCUtils.APC.PDU.Rule.DisposalSCUtils.APC.PDU.Devices.GroupMaintenanceTrueFalse
SCUtils.APC.PDU.Rule.humidityThresholdViolation1PDU Trap Alert Rule - Probe 1 humidity threshold violatedSCUtils.APC.PDU.Rule.humidityThresholdViolation1SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.humidityThresholdViolation2PDU Trap Alert Rule - Probe 2 humidity threshold violatedSCUtils.APC.PDU.Rule.humidityThresholdViolation2SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.humidityThresholdViolationCleared1PDU Trap Alert Rule - An Environmental Monitor humidity threshold violation has been cleared on probe 1SCUtils.APC.PDU.Rule.humidityThresholdViolationCleared1SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.humidityThresholdViolationCleared2PDU Trap Alert Rule - An Environmental Monitor humidity threshold violation has been cleared on probe 2SCUtils.APC.PDU.Rule.humidityThresholdViolationCleared2SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.outletOffPDU Trap Alert Rule - The specified PDU outlet has turned offSCUtils.APC.PDU.Rule.outletOffSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.outletOnPDU Trap Alert Rule - The specified PDU outlet has turned onSCUtils.APC.PDU.Rule.outletOnSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.outletRebootPDU Trap Alert Rule - The specified PDU outlet has rebootedSCUtils.APC.PDU.Rule.outletRebootSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.passwordChangePDU Trap Alert Rule - The password for the device has been changedSCUtils.APC.PDU.Rule.passwordChangeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduAtypicalBypassModePDU Trap Alert Rule - PDU is in Atypical Bypass ModeSCUtils.APC.PDU.Rule.pduAtypicalBypassModeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelFrequencyOutOfRangePDU Trap Alert Rule - Circuit Panel Input Frequency Out Of RangeSCUtils.APC.PDU.Rule.pduCircuitPanelFrequencyOutOfRangeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelFrequencyOutofRangeClearedPDU Trap Alert Rule - Circuit Panel Input Frequency No Longer Out Of RangeSCUtils.APC.PDU.Rule.pduCircuitPanelFrequencyOutofRangeClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputOvercurrentPDU Trap Alert Rule - Circuit Panel Input OvercurrentSCUtils.APC.PDU.Rule.pduCircuitPanelInputOvercurrentSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputOvercurrentClearedPDU Trap Alert Rule - Circuit Panel Input Overcurrent ClearedSCUtils.APC.PDU.Rule.pduCircuitPanelInputOvercurrentClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputOvervoltagePDU Trap Alert Rule - Circuit Panel Input OvervoltageSCUtils.APC.PDU.Rule.pduCircuitPanelInputOvervoltageSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputOvervoltageClearedPDU Trap Alert Rule - Circuit Panel Input Overvoltage ClearedSCUtils.APC.PDU.Rule.pduCircuitPanelInputOvervoltageClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputUndercurrentPDU Trap Alert Rule - Circuit Panel Input UndercurrentSCUtils.APC.PDU.Rule.pduCircuitPanelInputUndercurrentSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputUndercurrentClearedPDU Trap Alert Rule - Circuit Panel Input Undercurrent ClearedSCUtils.APC.PDU.Rule.pduCircuitPanelInputUndercurrentClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputUndervoltagePDU Trap Alert Rule - Circuit Panel Input UndervoltageSCUtils.APC.PDU.Rule.pduCircuitPanelInputUndervoltageSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelInputUndervoltageClearedPDU Trap Alert Rule - Circuit Panel Input Undervoltage ClearedSCUtils.APC.PDU.Rule.pduCircuitPanelInputUndervoltageClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelNeutralOvercurrentPDU Trap Alert Rule - Circuit Panel Input Neutral OvercurrentSCUtils.APC.PDU.Rule.pduCircuitPanelNeutralOvercurrentSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCircuitPanelNeutralOvercurrentClearedPDU Trap Alert Rule - Circuit Panel Input Neutral Overcurrent ClearedSCUtils.APC.PDU.Rule.pduCircuitPanelNeutralOvercurrentClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCommunicationEstablishedPDU Trap Alert Rule - Communication EstablishedSCUtils.APC.PDU.Rule.pduCommunicationEstablishedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduCommunicationLostPDU Trap Alert Rule - Communication LostSCUtils.APC.PDU.Rule.pduCommunicationLostSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduContactFaultPDU Trap Alert Rule - A contact closure in the PDU is in an abnormal positionSCUtils.APC.PDU.Rule.pduContactFaultSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduContactFaultClearedPDU Trap Alert Rule - A contact closure in the PDU is in a normal positionSCUtils.APC.PDU.Rule.pduContactFaultClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduForcedBypassModePDU Trap Alert Rule - PDU is in Forced Bypass ModeSCUtils.APC.PDU.Rule.pduForcedBypassModeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduGroundOvercurrentPDU Trap Alert Rule - Ground OvercurrentSCUtils.APC.PDU.Rule.pduGroundOvercurrentSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduGroundOvercurrentClearedPDU Trap Alert Rule - Ground Overcurrent ClearedSCUtils.APC.PDU.Rule.pduGroundOvercurrentClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduInputTransformerOverTemperaturePDU Trap Alert Rule - Input Transformer Over TemperatureSCUtils.APC.PDU.Rule.pduInputTransformerOverTemperatureSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduInputTransformerOverTemperatureClearedPDU Trap Alert Rule - Input Transformer Over Temperature ClearedSCUtils.APC.PDU.Rule.pduInputTransformerOverTemperatureClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduMaintenanceBypassModePDU Trap Alert Rule - PDU is in Maintenance Bypass ModeSCUtils.APC.PDU.Rule.pduMaintenanceBypassModeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduNoPanelFeedModePDU Trap Alert Rule - PDU is in No Panel Feed ModeSCUtils.APC.PDU.Rule.pduNoPanelFeedModeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduOnBatteryModePDU Trap Alert Rule - PDU is in On Battery ModeSCUtils.APC.PDU.Rule.pduOnBatteryModeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduSystemOffPDU Trap Alert Rule - PDU System OffSCUtils.APC.PDU.Rule.pduSystemOffSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUPSInputVoltageLostPDU Trap Alert Rule - UPS Input Voltage phase-N LostSCUtils.APC.PDU.Rule.pduUPSInputVoltageLostSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUPSInputVoltageRestoredPDU Trap Alert Rule - UPS Input Voltage phase-N RestoredSCUtils.APC.PDU.Rule.pduUPSInputVoltageRestoredSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUpsOperationModePDU Trap Alert Rule - PDU is in Ups Operation ModeSCUtils.APC.PDU.Rule.pduUpsOperationModeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUtilityLineOvervoltagePDU Trap Alert Rule - Utility Line OvervoltageSCUtils.APC.PDU.Rule.pduUtilityLineOvervoltageSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUtilityLineOvervoltageClearedPDU Trap Alert Rule - Utility Line Overvoltage ClearedSCUtils.APC.PDU.Rule.pduUtilityLineOvervoltageClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUtilityLineUndervoltagePDU Trap Alert Rule - Utility Line UndervoltageSCUtils.APC.PDU.Rule.pduUtilityLineUndervoltageSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.pduUtilityLineUndervoltageClearedPDU Trap Alert Rule - Utility Line Undervoltage ClearedSCUtils.APC.PDU.Rule.pduUtilityLineUndervoltageClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUBankPhaseLowLoadPDU Trap Alert Rule - A bank or phase on the Rack PDU has violated the low load thresholdSCUtils.APC.PDU.Rule.rPDUBankPhaseLowLoadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUBankPhaseLowLoadClearedPDU Trap Alert Rule - The bank or phase low load condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUBankPhaseLowLoadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUBankPhaseNearOverloadPDU Trap Alert Rule - A bank or phase of the Rack PDU is near an overload conditionSCUtils.APC.PDU.Rule.rPDUBankPhaseNearOverloadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUBankPhaseNearOverloadClearedPDU Trap Alert Rule - The bank or phase near overload condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUBankPhaseNearOverloadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUBankPhaseOverloadPDU Trap Alert Rule - A bank or phase of the Rack PDU is in an overload conditionSCUtils.APC.PDU.Rule.rPDUBankPhaseOverloadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUBankPhaseOverloadClearedPDU Trap Alert Rule - The bank or phase overload condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUBankPhaseOverloadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUCancelPendingCommandPDU Trap Alert Rule - A cancel pending command has been made on a Switched Rack PDUSCUtils.APC.PDU.Rule.rPDUCancelPendingCommandSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUCommunicationEstablishedPDU Trap Alert Rule - Communication with a Rack PDU has been establishedSCUtils.APC.PDU.Rule.rPDUCommunicationEstablishedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUCommunicationLostPDU Trap Alert Rule - Communication with a Rack PDU has been lostSCUtils.APC.PDU.Rule.rPDUCommunicationLostSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rpduCriticalConditionPDU Trap Alert Rule - A RPDU critical condition has been detectedSCUtils.APC.PDU.Rule.rpduCriticalConditionSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rpduCriticalConditionClearedPDU Trap Alert Rule - A RPDU critical condition has been clearedSCUtils.APC.PDU.Rule.rpduCriticalConditionClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUDeviceConfigChangePDU Trap Alert Rule - A device configuration change has been made on a Rack PDUSCUtils.APC.PDU.Rule.rPDUDeviceConfigChangeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rpduInformationalConditionPDU Trap Alert Rule - A RPDU informational condition has been detected.SCUtils.APC.PDU.Rule.rpduInformationalConditionSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rpduInformationalConditionClearedPDU Trap Alert Rule - A RPDU informational condition has been cleared.SCUtils.APC.PDU.Rule.rpduInformationalConditionClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDULoadStatusLoadPhase/Bank Load RuleSCUtils.APC.PDU.Rule.rPDULoadStatusLoadSCUtils.APC.PDU.PhaseBankPerformanceCollectionTrueFalse
SCUtils.APC.PDU.Rule.rPDULowLoadPDU Trap Alert Rule - A Rack PDU has violated the low load thresholdSCUtils.APC.PDU.Rule.rPDULowLoadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDULowLoadClearedPDU Trap Alert Rule - The low load condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDULowLoadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUNearOverloadPDU Trap Alert Rule - A Rack PDU is near an overload conditionSCUtils.APC.PDU.Rule.rPDUNearOverloadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUNearOverloadClearedPDU Trap Alert Rule - The near overload condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUNearOverloadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletConfigChangePDU Trap Alert Rule - An outlet configuration change has been made on a Switched Rack PDUSCUtils.APC.PDU.Rule.rPDUOutletConfigChangeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletLowLoadPDU Trap Alert Rule - A Rack PDU has violated the outlet low load thresholdSCUtils.APC.PDU.Rule.rPDUOutletLowLoadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletLowLoadClearedPDU Trap Alert Rule - The outlet low load condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUOutletLowLoadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletNearOverloadPDU Trap Alert Rule - A Rack PDU is near an outlet overload conditionSCUtils.APC.PDU.Rule.rPDUOutletNearOverloadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletNearOverloadClearedPDU Trap Alert Rule - The outlet near overload condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUOutletNearOverloadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletOffPDU Trap Alert Rule - An outlet on a Switched Rack PDU has turned offSCUtils.APC.PDU.Rule.rPDUOutletOffSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletOnPDU Trap Alert Rule - An outlet on a Switched Rack PDU has turned onSCUtils.APC.PDU.Rule.rPDUOutletOnSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletOverloadPDU Trap Alert Rule - A Rack PDU is in an overload conditionSCUtils.APC.PDU.Rule.rPDUOutletOverloadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOutletOverloadClearedPDU Trap Alert Rule - The outlet overload condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUOutletOverloadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOverloadPDU Trap Alert Rule - A Rack PDU is in an overload conditionSCUtils.APC.PDU.Rule.rPDUOverloadSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUOverloadClearedPDU Trap Alert Rule - The overload condition on a Rack PDU has been clearedSCUtils.APC.PDU.Rule.rPDUOverloadClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUPhaseConfigChangePDU Trap Alert Rule - A phase configuration change has been made on a Rack PDUSCUtils.APC.PDU.Rule.rPDUPhaseConfigChangeSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUPowerSupply1FailPDU Trap Alert Rule - Power Supply 1 on Rack PDU is in FAIL stateSCUtils.APC.PDU.Rule.rPDUPowerSupply1FailSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUPowerSupply1OkPDU Trap Alert Rule - Power Supply 1 on Rack PDU is operating normallySCUtils.APC.PDU.Rule.rPDUPowerSupply1OkSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUPowerSupply2FailPDU Trap Alert Rule - Power Supply 2 on Rack PDU is in FAIL stateSCUtils.APC.PDU.Rule.rPDUPowerSupply2FailSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rPDUPowerSupply2OkPDU Trap Alert Rule - Power Supply 2 on Rack PDU is operating normallySCUtils.APC.PDU.Rule.rPDUPowerSupply2OkSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rpduWarningConditionPDU Trap Alert Rule - A RPDU warning condition has been detectedSCUtils.APC.PDU.Rule.rpduWarningConditionSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.rpduWarningConditionClearedPDU Trap Alert Rule - A RPDU warning condition has been clearedSCUtils.APC.PDU.Rule.rpduWarningConditionClearedSCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.temperatureThresholdViolation1PDU Trap Alert Rule - An Environmental Monitor temperature threshold has been violated on probe 1SCUtils.APC.PDU.Rule.temperatureThresholdViolation1SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.temperatureThresholdViolation2PDU Trap Alert Rule - An Environmental Monitor temperature threshold has been violated on probe 2SCUtils.APC.PDU.Rule.temperatureThresholdViolation2SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.temperatureThresholdViolationCleared1PDU Trap Alert Rule - An Environmental Monitor temperature threshold violation has been cleared on probe 1SCUtils.APC.PDU.Rule.temperatureThresholdViolationCleared1SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU.Rule.temperatureThresholdViolationCleared2PDU Trap Alert Rule - An Environmental Monitor temperature threshold violation has been cleared on probe 2SCUtils.APC.PDU.Rule.temperatureThresholdViolationCleared2SCUtils.APC.PDUAlertTrueTrue
SCUtils.APC.PDU2.Bank.Rule.rPDU2BankStatusCurrentBank current draw, in Amps RuleSCUtils.APC.PDU2.Bank.Rule.rPDU2BankStatusCurrentSCUtils.APC.PDU2.BankPerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusApparentPowerPDU load in kiloVoltAmps (kVA) RuleSCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusApparentPowerSCUtils.APC.PDU2.DevicePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusEnergyPDU load energy RuleSCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusEnergySCUtils.APC.PDU2.DevicePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusPowerPDU load in kilowatts RuleSCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusPowerSCUtils.APC.PDU2.DevicePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusCurrentOutlet current draw, in Amps RuleSCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusCurrentSCUtils.APC.PDU2.OutletMeteredPerformanceCollectionTrueFalse
SCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusEnergyOutlet load energy consumption, in kilowatt-hours RuleSCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusEnergySCUtils.APC.PDU2.OutletMeteredPerformanceCollectionTrueFalse
SCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusPowerPower draw of the load RuleSCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusPowerSCUtils.APC.PDU2.OutletMeteredPerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusApparentPowerPhase load apparent power in kiloVoltAmps (kVA) RuleSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusApparentPowerSCUtils.APC.PDU2.PhasePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusCurrentPhase current draw in Amps RuleSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusCurrentSCUtils.APC.PDU2.PhasePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPowerPhase load power in kilowatts (kW) RuleSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPowerSCUtils.APC.PDU2.PhasePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPowerFactorPhase load power factor RuleSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPowerFactorSCUtils.APC.PDU2.PhasePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusVoltagePhase Voltage, in Volts RuleSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusVoltageSCUtils.APC.PDU2.PhasePerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Rule.accessViolationConsolePDU2 Trap Alert Rule - Someone has attempted to login via the console with the incorrect passwordSCUtils.APC.PDU2.Rule.accessViolationConsoleSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.accessViolationHTTPPDU2 Trap Alert Rule - Someone has attempted to login via HTTP with the incorrect passwordSCUtils.APC.PDU2.Rule.accessViolationHTTPSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.apcTestTrapPDU2 Trap Alert Rule - Trap used to test SNMP trap functionalitySCUtils.APC.PDU2.Rule.apcTestTrapSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.configChangeOutletPDU2 Trap Alert Rule - The specified PDU outlet has changed configuration.SCUtils.APC.PDU2.Rule.configChangeOutletSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.configChangeSNMPPDU2 Trap Alert Rule - The SNMP configuration has been changedSCUtils.APC.PDU2.Rule.configChangeSNMPSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.humidityThresholdViolation1PDU2 Trap Alert Rule - Probe 1 humidity threshold violatedSCUtils.APC.PDU2.Rule.humidityThresholdViolation1SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.humidityThresholdViolation2PDU2 Trap Alert Rule - Probe 2 humidity threshold violatedSCUtils.APC.PDU2.Rule.humidityThresholdViolation2SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.humidityThresholdViolationCleared1PDU2 Trap Alert Rule - An Environmental Monitor humidity threshold violation has been cleared on probe 1SCUtils.APC.PDU2.Rule.humidityThresholdViolationCleared1SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.humidityThresholdViolationCleared2PDU2 Trap Alert Rule - An Environmental Monitor humidity threshold violation has been cleared on probe 2SCUtils.APC.PDU2.Rule.humidityThresholdViolationCleared2SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.outletOffPDU2 Trap Alert Rule - The specified PDU outlet has turned offSCUtils.APC.PDU2.Rule.outletOffSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.outletOnPDU2 Trap Alert Rule - The specified PDU outlet has turned onSCUtils.APC.PDU2.Rule.outletOnSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.outletRebootPDU2 Trap Alert Rule - The specified PDU outlet has rebootedSCUtils.APC.PDU2.Rule.outletRebootSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.passwordChangePDU2 Trap Alert Rule - The password for the device has been changedSCUtils.APC.PDU2.Rule.passwordChangeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduAtypicalBypassModePDU2 Trap Alert Rule - PDU is in Atypical Bypass ModeSCUtils.APC.PDU2.Rule.pduAtypicalBypassModeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelFrequencyOutOfRangePDU2 Trap Alert Rule - Circuit Panel Input Frequency Out Of RangeSCUtils.APC.PDU2.Rule.pduCircuitPanelFrequencyOutOfRangeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelFrequencyOutofRangeClearedPDU2 Trap Alert Rule - Circuit Panel Input Frequency No Longer Out Of RangeSCUtils.APC.PDU2.Rule.pduCircuitPanelFrequencyOutofRangeClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvercurrentPDU2 Trap Alert Rule - Circuit Panel Input OvercurrentSCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvercurrentSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvercurrentClearedPDU2 Trap Alert Rule - Circuit Panel Input Overcurrent ClearedSCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvercurrentClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvervoltagePDU2 Trap Alert Rule - Circuit Panel Input OvervoltageSCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvervoltageSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvervoltageClearedPDU2 Trap Alert Rule - Circuit Panel Input Overvoltage ClearedSCUtils.APC.PDU2.Rule.pduCircuitPanelInputOvervoltageClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndercurrentPDU2 Trap Alert Rule - Circuit Panel Input UndercurrentSCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndercurrentSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndercurrentClearedPDU2 Trap Alert Rule - Circuit Panel Input Undercurrent ClearedSCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndercurrentClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndervoltagePDU2 Trap Alert Rule - Circuit Panel Input UndervoltageSCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndervoltageSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndervoltageClearedPDU2 Trap Alert Rule - Circuit Panel Input Undervoltage ClearedSCUtils.APC.PDU2.Rule.pduCircuitPanelInputUndervoltageClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelNeutralOvercurrentPDU2 Trap Alert Rule - Circuit Panel Input Neutral OvercurrentSCUtils.APC.PDU2.Rule.pduCircuitPanelNeutralOvercurrentSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCircuitPanelNeutralOvercurrentClearedPDU2 Trap Alert Rule - Circuit Panel Input Neutral Overcurrent ClearedSCUtils.APC.PDU2.Rule.pduCircuitPanelNeutralOvercurrentClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCommunicationEstablishedPDU2 Trap Alert Rule - Communication EstablishedSCUtils.APC.PDU2.Rule.pduCommunicationEstablishedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduCommunicationLostPDU2 Trap Alert Rule - Communication LostSCUtils.APC.PDU2.Rule.pduCommunicationLostSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduContactFaultPDU2 Trap Alert Rule - A contact closure in the PDU is in an abnormal positionSCUtils.APC.PDU2.Rule.pduContactFaultSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduContactFaultClearedPDU2 Trap Alert Rule - A contact closure in the PDU is in a normal positionSCUtils.APC.PDU2.Rule.pduContactFaultClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduForcedBypassModePDU2 Trap Alert Rule - PDU is in Forced Bypass ModeSCUtils.APC.PDU2.Rule.pduForcedBypassModeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduGroundOvercurrentPDU2 Trap Alert Rule - Ground OvercurrentSCUtils.APC.PDU2.Rule.pduGroundOvercurrentSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduGroundOvercurrentClearedPDU2 Trap Alert Rule - Ground Overcurrent ClearedSCUtils.APC.PDU2.Rule.pduGroundOvercurrentClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduInputTransformerOverTemperaturePDU2 Trap Alert Rule - Input Transformer Over TemperatureSCUtils.APC.PDU2.Rule.pduInputTransformerOverTemperatureSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduInputTransformerOverTemperatureClearedPDU2 Trap Alert Rule - Input Transformer Over Temperature ClearedSCUtils.APC.PDU2.Rule.pduInputTransformerOverTemperatureClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduMaintenanceBypassModePDU2 Trap Alert Rule - PDU is in Maintenance Bypass ModeSCUtils.APC.PDU2.Rule.pduMaintenanceBypassModeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduNoPanelFeedModePDU2 Trap Alert Rule - PDU is in No Panel Feed ModeSCUtils.APC.PDU2.Rule.pduNoPanelFeedModeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduOnBatteryModePDU2 Trap Alert Rule - PDU is in On Battery ModeSCUtils.APC.PDU2.Rule.pduOnBatteryModeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduSystemOffPDU2 Trap Alert Rule - PDU System OffSCUtils.APC.PDU2.Rule.pduSystemOffSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUPSInputVoltageLostPDU2 Trap Alert Rule - UPS Input Voltage phase-N LostSCUtils.APC.PDU2.Rule.pduUPSInputVoltageLostSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUPSInputVoltageRestoredPDU2 Trap Alert Rule - UPS Input Voltage phase-N RestoredSCUtils.APC.PDU2.Rule.pduUPSInputVoltageRestoredSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUpsOperationModePDU2 Trap Alert Rule - PDU is in Ups Operation ModeSCUtils.APC.PDU2.Rule.pduUpsOperationModeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUtilityLineOvervoltagePDU2 Trap Alert Rule - Utility Line OvervoltageSCUtils.APC.PDU2.Rule.pduUtilityLineOvervoltageSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUtilityLineOvervoltageClearedPDU2 Trap Alert Rule - Utility Line Overvoltage ClearedSCUtils.APC.PDU2.Rule.pduUtilityLineOvervoltageClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUtilityLineUndervoltagePDU2 Trap Alert Rule - Utility Line UndervoltageSCUtils.APC.PDU2.Rule.pduUtilityLineUndervoltageSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.pduUtilityLineUndervoltageClearedPDU2 Trap Alert Rule - Utility Line Undervoltage ClearedSCUtils.APC.PDU2.Rule.pduUtilityLineUndervoltageClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUBankPhaseLowLoadPDU2 Trap Alert Rule - A bank or phase on the Rack PDU has violated the low load thresholdSCUtils.APC.PDU2.Rule.rPDUBankPhaseLowLoadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUBankPhaseLowLoadClearedPDU2 Trap Alert Rule - The bank or phase low load condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUBankPhaseLowLoadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUBankPhaseNearOverloadPDU2 Trap Alert Rule - A bank or phase of the Rack PDU is near an overload conditionSCUtils.APC.PDU2.Rule.rPDUBankPhaseNearOverloadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUBankPhaseNearOverloadClearedPDU2 Trap Alert Rule - The bank or phase near overload condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUBankPhaseNearOverloadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUBankPhaseOverloadPDU2 Trap Alert Rule - A bank or phase of the Rack PDU is in an overload conditionSCUtils.APC.PDU2.Rule.rPDUBankPhaseOverloadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUBankPhaseOverloadClearedPDU2 Trap Alert Rule - The bank or phase overload condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUBankPhaseOverloadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUCancelPendingCommandPDU2 Trap Alert Rule - A cancel pending command has been made on a Switched Rack PDUSCUtils.APC.PDU2.Rule.rPDUCancelPendingCommandSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUCommunicationEstablishedPDU2 Trap Alert Rule - Communication with a Rack PDU has been establishedSCUtils.APC.PDU2.Rule.rPDUCommunicationEstablishedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUCommunicationLostPDU2 Trap Alert Rule - Communication with a Rack PDU has been lostSCUtils.APC.PDU2.Rule.rPDUCommunicationLostSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rpduCriticalConditionPDU2 Trap Alert Rule - A RPDU critical condition has been detectedSCUtils.APC.PDU2.Rule.rpduCriticalConditionSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rpduCriticalConditionClearedPDU2 Trap Alert Rule - A RPDU critical condition has been clearedSCUtils.APC.PDU2.Rule.rpduCriticalConditionClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUDeviceConfigChangePDU2 Trap Alert Rule - A device configuration change has been made on a Rack PDUSCUtils.APC.PDU2.Rule.rPDUDeviceConfigChangeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rpduInformationalConditionPDU2 Trap Alert Rule - A RPDU informational condition has been detected.SCUtils.APC.PDU2.Rule.rpduInformationalConditionSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rpduInformationalConditionClearedPDU2 Trap Alert Rule - A RPDU informational condition has been cleared.SCUtils.APC.PDU2.Rule.rpduInformationalConditionClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDULowLoadPDU2 Trap Alert Rule - A Rack PDU has violated the low load thresholdSCUtils.APC.PDU2.Rule.rPDULowLoadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDULowLoadClearedPDU2 Trap Alert Rule - The low load condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDULowLoadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUNearOverloadPDU2 Trap Alert Rule - A Rack PDU is near an overload conditionSCUtils.APC.PDU2.Rule.rPDUNearOverloadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUNearOverloadClearedPDU2 Trap Alert Rule - The near overload condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUNearOverloadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletConfigChangePDU2 Trap Alert Rule - An outlet configuration change has been made on a Switched Rack PDUSCUtils.APC.PDU2.Rule.rPDUOutletConfigChangeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletLowLoadPDU2 Trap Alert Rule - A Rack PDU has violated the outlet low load thresholdSCUtils.APC.PDU2.Rule.rPDUOutletLowLoadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletLowLoadClearedPDU2 Trap Alert Rule - The outlet low load condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUOutletLowLoadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletNearOverloadPDU2 Trap Alert Rule - A Rack PDU is near an outlet overload conditionSCUtils.APC.PDU2.Rule.rPDUOutletNearOverloadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletNearOverloadClearedPDU2 Trap Alert Rule - The outlet near overload condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUOutletNearOverloadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletOffPDU2 Trap Alert Rule - An outlet on a Switched Rack PDU has turned offSCUtils.APC.PDU2.Rule.rPDUOutletOffSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletOnPDU2 Trap Alert Rule - An outlet on a Switched Rack PDU has turned onSCUtils.APC.PDU2.Rule.rPDUOutletOnSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletOverloadPDU2 Trap Alert Rule - A Rack PDU is in an overload conditionSCUtils.APC.PDU2.Rule.rPDUOutletOverloadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOutletOverloadClearedPDU2 Trap Alert Rule - The outlet overload condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUOutletOverloadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOverloadPDU2 Trap Alert Rule - A Rack PDU is in an overload conditionSCUtils.APC.PDU2.Rule.rPDUOverloadSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUOverloadClearedPDU2 Trap Alert Rule - The overload condition on a Rack PDU has been clearedSCUtils.APC.PDU2.Rule.rPDUOverloadClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUPhaseConfigChangePDU2 Trap Alert Rule - A phase configuration change has been made on a Rack PDUSCUtils.APC.PDU2.Rule.rPDUPhaseConfigChangeSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUPowerSupply1FailPDU2 Trap Alert Rule - Power Supply 1 on Rack PDU is in FAIL stateSCUtils.APC.PDU2.Rule.rPDUPowerSupply1FailSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUPowerSupply1OkPDU2 Trap Alert Rule - Power Supply 1 on Rack PDU is operating normallySCUtils.APC.PDU2.Rule.rPDUPowerSupply1OkSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUPowerSupply2FailPDU2 Trap Alert Rule - Power Supply 2 on Rack PDU is in FAIL stateSCUtils.APC.PDU2.Rule.rPDUPowerSupply2FailSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rPDUPowerSupply2OkPDU2 Trap Alert Rule - Power Supply 2 on Rack PDU is operating normallySCUtils.APC.PDU2.Rule.rPDUPowerSupply2OkSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rpduWarningConditionPDU2 Trap Alert Rule - A RPDU warning condition has been detectedSCUtils.APC.PDU2.Rule.rpduWarningConditionSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.rpduWarningConditionClearedPDU2 Trap Alert Rule - A RPDU warning condition has been clearedSCUtils.APC.PDU2.Rule.rpduWarningConditionClearedSCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.temperatureThresholdViolation1PDU2 Trap Alert Rule - An Environmental Monitor temperature threshold has been violated on probe 1SCUtils.APC.PDU2.Rule.temperatureThresholdViolation1SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.temperatureThresholdViolation2PDU2 Trap Alert Rule - An Environmental Monitor temperature threshold has been violated on probe 2SCUtils.APC.PDU2.Rule.temperatureThresholdViolation2SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.temperatureThresholdViolationCleared1PDU2 Trap Alert Rule - An Environmental Monitor temperature threshold violation has been cleared on probe 1SCUtils.APC.PDU2.Rule.temperatureThresholdViolationCleared1SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Rule.temperatureThresholdViolationCleared2PDU2 Trap Alert Rule - An Environmental Monitor temperature threshold violation has been cleared on probe 2SCUtils.APC.PDU2.Rule.temperatureThresholdViolationCleared2SCUtils.APC.PDU2AlertTrueTrue
SCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusRelativeHumiditySensor humidity reading in percent relative humidity RuleSCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusRelativeHumiditySCUtils.APC.PDU2.SensorPerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempCSensor temperature reading in degrees Celsius RuleSCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempCSCUtils.APC.PDU2.SensorPerformanceCollectionTrueFalse
SCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempFSensor temperature reading in degrees Fahrenheit RuleSCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempFSCUtils.APC.PDU2.SensorPerformanceCollectionTrueFalse

Agent Tasks (3)

 DisplayNameIDTargetAccessibilityCategoryEnabled
SCUtils.APC.PDU.Activate.TaskActivateSCUtils.APC.PDU.Activate.TaskSCUtils.APC.PDU.AdminSettings.ActivationInternalCustomTrue
SCUtils.APC.PDU.CheckLicense.TaskCheck a licenseSCUtils.APC.PDU.CheckLicense.TaskSCUtils.APC.PDU.AdminSettings.ActivationInternalCustomTrue
SCUtils.APC.PDU.GetUniqueID.TaskGet Unique ID for an offline activationSCUtils.APC.PDU.GetUniqueID.TaskSCUtils.APC.PDU.AdminSettings.ActivationInternalCustomTrue

Console Tasks (4)

 DisplayNameIDTargetAccessibilityEnabled
SCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.HttpOpen APC PDU web interface using 80 portSCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.HttpSCUtils.APC.PDUPublicTrue
SCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.HttpsOpen APC PDU web interface using 443 portSCUtils.APC.PDU.ConsoleTasks.OpenWebConsole.HttpsSCUtils.APC.PDUPublicTrue
SCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.HttpOpen APC PDU2 web interface using 80 portSCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.HttpSCUtils.APC.PDU2PublicTrue
SCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.HttpsOpen APC PDU2 web interface using 443 portSCUtils.APC.PDU2.ConsoleTasks.OpenWebConsole.HttpsSCUtils.APC.PDU2PublicTrue

Folder Items (7)

 IDFolderNameElementID
SCUtils.APC.PDU.Devices.AlertView.FolderItemSCUtils.APC.PDU.Devices.AlertView.FolderItemSCUtils.APC.PDU.Devices.AlertView.FolderSCUtils.APC.PDU.Devices.AlertView
SCUtils.APC.PDU.Devices.DiagramView.FolderItemSCUtils.APC.PDU.Devices.DiagramView.FolderItemSCUtils.APC.PDU.Devices.FolderSCUtils.APC.PDU.Devices.DiagramView
SCUtils.APC.PDU.Devices.PerformanceView.FolderItemSCUtils.APC.PDU.Devices.PerformanceView.FolderItemSCUtils.APC.PDU.Devices.PerformanceView.FolderSCUtils.APC.PDU.Devices.PerformanceView
SCUtils.APC.PDU.Devices.StateView.FolderItemSCUtils.APC.PDU.Devices.StateView.FolderItemSCUtils.APC.PDU.Devices.StateView.FolderSCUtils.APC.PDU.Devices.StateView
SCUtils.APC.PDU2.Devices.AlertView.FolderItemSCUtils.APC.PDU2.Devices.AlertView.FolderItemSCUtils.APC.PDU.Devices.AlertView.FolderSCUtils.APC.PDU2.Devices.AlertView
SCUtils.APC.PDU2.Devices.PerformanceView.FolderItemSCUtils.APC.PDU2.Devices.PerformanceView.FolderItemSCUtils.APC.PDU.Devices.PerformanceView.FolderSCUtils.APC.PDU2.Devices.PerformanceView
SCUtils.APC.PDU2.Devices.StateView.FolderItemSCUtils.APC.PDU2.Devices.StateView.FolderItemSCUtils.APC.PDU.Devices.StateView.FolderSCUtils.APC.PDU2.Devices.StateView

Folders (4)

 DisplayNameIDParentFolderAccessibility
SCUtils.APC.PDU.Devices.AlertView.FolderAlert ViewSCUtils.APC.PDU.Devices.AlertView.FolderSCUtils.APC.PDU.Devices.FolderPublic
SCUtils.APC.PDU.Devices.FolderAPC PDUSCUtils.APC.PDU.Devices.FolderMicrosoft.SystemCenter.Monitoring.ViewFolder.RootPublic
SCUtils.APC.PDU.Devices.PerformanceView.FolderPerformance ViewSCUtils.APC.PDU.Devices.PerformanceView.FolderSCUtils.APC.PDU.Devices.FolderPublic
SCUtils.APC.PDU.Devices.StateView.FolderState ViewSCUtils.APC.PDU.Devices.StateView.FolderSCUtils.APC.PDU.Devices.FolderPublic

Image References (18)

 DisplayNameIDImageID
SCUtils.APC.PDUAPC PDUSCUtils.APC.PDUSCUtils.APC.PDU_80.Icon
SCUtils.APC.PDU.OutletPDU Outlet LoadSCUtils.APC.PDU.OutletSCUtils.APC.PDU.Outlet_80.Icon
SCUtils.APC.PDU.OutletsPDU OutletsSCUtils.APC.PDU.OutletsSCUtils.APC.PDU.Outlets_80.Icon
SCUtils.APC.PDU.PhaseBankPDU Phase/BankSCUtils.APC.PDU.PhaseBankSCUtils.APC.PDU.PhaseBank_16.Icon
SCUtils.APC.PDU.PhasesPDU Phases/BanksSCUtils.APC.PDU.PhasesSCUtils.APC.PDU.Phases_80.Icon
SCUtils.APC.PDU2APC PDU2SCUtils.APC.PDU2SCUtils.APC.PDU2_80.Icon
SCUtils.APC.PDU2.BankPDU BankSCUtils.APC.PDU2.BankSCUtils.APC.PDU2.Bank_80.Icon
SCUtils.APC.PDU2.BanksPDU BanksSCUtils.APC.PDU2.BanksSCUtils.APC.PDU2.Banks_80.Icon
SCUtils.APC.PDU2.DeviceAPC PDU2 DeviceSCUtils.APC.PDU2.DeviceSCUtils.APC.PDU2.Device_80.Icon
SCUtils.APC.PDU2.DevicesAPC PDU2 DevicesSCUtils.APC.PDU2.DevicesSCUtils.APC.PDU2.Devices_80.Icon
SCUtils.APC.PDU2.OutletMeteredPDU Outlet MeteredSCUtils.APC.PDU2.OutletMeteredSCUtils.APC.PDU2.OutletMetered_80.Icon
SCUtils.APC.PDU2.OutletsPDU OutletsSCUtils.APC.PDU2.OutletsSCUtils.APC.PDU2.Outlets_80.Icon
SCUtils.APC.PDU2.OutletSwitchedPDU Outlet SwitchedSCUtils.APC.PDU2.OutletSwitchedSCUtils.APC.PDU2.OutletSwitched_80.Icon
SCUtils.APC.PDU2.PhasePDU PhaseSCUtils.APC.PDU2.PhaseSCUtils.APC.PDU2.Phase_80.Icon
SCUtils.APC.PDU2.PhasesPDU PhasesSCUtils.APC.PDU2.PhasesSCUtils.APC.PDU2.Phases_80.Icon
SCUtils.APC.PDU2.SensorPDU SensorSCUtils.APC.PDU2.SensorSCUtils.APC.PDU2.Sensor_80.Icon
SCUtils.APC.PDU2.SensorDiscretePDU Discrete SensorSCUtils.APC.PDU2.SensorDiscreteSCUtils.APC.PDU2.SensorDiscrete_80.Icon
SCUtils.APC.PDU2.SensorsPDU SensorsSCUtils.APC.PDU2.SensorsSCUtils.APC.PDU2.Sensors_80.Icon

Views (7)

 DisplayNameIDTargetTypeAccessibilityVisible
SCUtils.APC.PDU.Devices.AlertViewPDU Alert ViewSCUtils.APC.PDU.Devices.AlertViewSCUtils.APC.PDUMicrosoft.SystemCenter.AlertViewTypePublicTrue
SCUtils.APC.PDU.Devices.DiagramViewDiagram ViewSCUtils.APC.PDU.Devices.DiagramViewSCUtils.APC.PDU.Devices.GroupMicrosoft.SystemCenter.DiagramViewTypePublicTrue
SCUtils.APC.PDU.Devices.PerformanceViewPDU Performance ViewSCUtils.APC.PDU.Devices.PerformanceViewSCUtils.APC.PDUMicrosoft.SystemCenter.PerformanceViewTypePublicTrue
SCUtils.APC.PDU.Devices.StateViewPDU State ViewSCUtils.APC.PDU.Devices.StateViewSCUtils.APC.PDUMicrosoft.SystemCenter.StateViewTypePublicTrue
SCUtils.APC.PDU2.Devices.AlertViewPDU2 Alert ViewSCUtils.APC.PDU2.Devices.AlertViewSCUtils.APC.PDU2Microsoft.SystemCenter.AlertViewTypePublicTrue
SCUtils.APC.PDU2.Devices.PerformanceViewPDU2 Performance ViewSCUtils.APC.PDU2.Devices.PerformanceViewSCUtils.APC.PDU2Microsoft.SystemCenter.PerformanceViewTypePublicTrue
SCUtils.APC.PDU2.Devices.StateViewPDU2 State ViewSCUtils.APC.PDU2.Devices.StateViewSCUtils.APC.PDU2Microsoft.SystemCenter.StateViewTypePublicTrue

Deployable Assemblies (1)

 IDFile NameAccessibility
Res.SCUtils.APC.PDU.LibraryRes.SCUtils.APC.PDU.LibrarySCUtils.APC.PDU.Library.dllPublic

Images (36)

 IDFile NameAccessibility
SCUtils.APC.PDU.Outlets_16.IconSCUtils.APC.PDU.Outlets_16.IconOutlets16.pngPublic
SCUtils.APC.PDU.Outlets_80.IconSCUtils.APC.PDU.Outlets_80.IconOutlets80.pngPublic
SCUtils.APC.PDU.Outlet_16.IconSCUtils.APC.PDU.Outlet_16.IconOutlet16.pngPublic
SCUtils.APC.PDU.Outlet_80.IconSCUtils.APC.PDU.Outlet_80.IconOutlet80.pngPublic
SCUtils.APC.PDU.PhaseBank_16.IconSCUtils.APC.PDU.PhaseBank_16.IconPhase16.pngPublic
SCUtils.APC.PDU.PhaseBank_80.IconSCUtils.APC.PDU.PhaseBank_80.IconPhase80.pngPublic
SCUtils.APC.PDU.Phases_16.IconSCUtils.APC.PDU.Phases_16.IconPhase16.pngPublic
SCUtils.APC.PDU.Phases_80.IconSCUtils.APC.PDU.Phases_80.IconPhase80.pngPublic
SCUtils.APC.PDU2.Banks_16.IconSCUtils.APC.PDU2.Banks_16.IconBanks16.pngPublic
SCUtils.APC.PDU2.Banks_80.IconSCUtils.APC.PDU2.Banks_80.IconBanks80.pngPublic
SCUtils.APC.PDU2.Bank_16.IconSCUtils.APC.PDU2.Bank_16.IconBank16.pngPublic
SCUtils.APC.PDU2.Bank_80.IconSCUtils.APC.PDU2.Bank_80.IconBank80.pngPublic
SCUtils.APC.PDU2.Devices_16.IconSCUtils.APC.PDU2.Devices_16.IconPDUs16.pngPublic
SCUtils.APC.PDU2.Devices_80.IconSCUtils.APC.PDU2.Devices_80.IconPDUs80.pngPublic
SCUtils.APC.PDU2.Device_16.IconSCUtils.APC.PDU2.Device_16.IconPDU216.pngPublic
SCUtils.APC.PDU2.Device_80.IconSCUtils.APC.PDU2.Device_80.IconPDU280.pngPublic
SCUtils.APC.PDU2.OutletMetered_16.IconSCUtils.APC.PDU2.OutletMetered_16.IconMeteredOutlet16.pngPublic
SCUtils.APC.PDU2.OutletMetered_80.IconSCUtils.APC.PDU2.OutletMetered_80.IconMeteredOutlet80.pngPublic
SCUtils.APC.PDU2.OutletSwitched_16.IconSCUtils.APC.PDU2.OutletSwitched_16.IconSwitchedOutlet16.pngPublic
SCUtils.APC.PDU2.OutletSwitched_80.IconSCUtils.APC.PDU2.OutletSwitched_80.IconSwitchedOutlet80.pngPublic
SCUtils.APC.PDU2.Outlets_16.IconSCUtils.APC.PDU2.Outlets_16.IconOutlets16.pngPublic
SCUtils.APC.PDU2.Outlets_80.IconSCUtils.APC.PDU2.Outlets_80.IconOutlets80.pngPublic
SCUtils.APC.PDU2.Phases_16.IconSCUtils.APC.PDU2.Phases_16.IconPhase16.pngPublic
SCUtils.APC.PDU2.Phases_80.IconSCUtils.APC.PDU2.Phases_80.IconPhase80.pngPublic
SCUtils.APC.PDU2.Phase_16.IconSCUtils.APC.PDU2.Phase_16.IconPhase16.pngPublic
SCUtils.APC.PDU2.Phase_80.IconSCUtils.APC.PDU2.Phase_80.IconPhase80.pngPublic
SCUtils.APC.PDU2.SensorDiscrete_16.IconSCUtils.APC.PDU2.SensorDiscrete_16.IconDiscreteSensor16.pngPublic
SCUtils.APC.PDU2.SensorDiscrete_80.IconSCUtils.APC.PDU2.SensorDiscrete_80.IconDiscreteSensor80.pngPublic
SCUtils.APC.PDU2.Sensors_16.IconSCUtils.APC.PDU2.Sensors_16.IconSensors16.pngPublic
SCUtils.APC.PDU2.Sensors_80.IconSCUtils.APC.PDU2.Sensors_80.IconSensors80.pngPublic
SCUtils.APC.PDU2.Sensor_16.IconSCUtils.APC.PDU2.Sensor_16.IconSensor16.pngPublic
SCUtils.APC.PDU2.Sensor_80.IconSCUtils.APC.PDU2.Sensor_80.IconSensor80.pngPublic
SCUtils.APC.PDU2_16.IconSCUtils.APC.PDU2_16.IconPDU216.pngPublic
SCUtils.APC.PDU2_80.IconSCUtils.APC.PDU2_80.IconPDU280.pngPublic
SCUtils.APC.PDU_16.IconSCUtils.APC.PDU_16.IconPDU16.pngPublic
SCUtils.APC.PDU_80.IconSCUtils.APC.PDU_80.IconPDU80.pngPublic

Linked Reports (19)

 DisplayNameIDBaseTargetAccessibilityVisible
SCUtils.APC.PDU.General.Information.ReportAPC PDU General Information ReportSCUtils.APC.PDU.General.Information.ReportMicrosoft.SystemCenter.DataWarehouse.Report.CustomConfigurationSCUtils.APC.PDUPublicTrue
SCUtils.APC.PDU.Rule.rPDULoadStatusLoad.ReportAPC PDU Phase/Bank Status Load ReportSCUtils.APC.PDU.Rule.rPDULoadStatusLoad.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU.PhaseBankPublicTrue
SCUtils.APC.PDU2.Bank.Rule.rPDU2BankStatusCurrent.ReportAPC PDU2 Bank current draw, in Amps, ReportSCUtils.APC.PDU2.Bank.Rule.rPDU2BankStatusCurrent.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.BankPublicTrue
SCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusApparentPower.ReportAPC PDU2 load, in kiloVoltAmps (kVA), ReportSCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusApparentPower.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.DevicePublicTrue
SCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusEnergy.ReportAPC PDU2 load energy consumption, in kilowatt-hours, ReportSCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusEnergy.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.DevicePublicTrue
SCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusPower.ReportAPC PDU2 load, in kilowatts, ReportSCUtils.APC.PDU2.Device.Rule.rPDU2DeviceStatusPower.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.DevicePublicTrue
SCUtils.APC.PDU2.General.Information.ReportAPC PDU2 General Information ReportSCUtils.APC.PDU2.General.Information.ReportMicrosoft.SystemCenter.DataWarehouse.Report.CustomConfigurationSCUtils.APC.PDU2PublicTrue
SCUtils.APC.PDU2.NPS.Device.General.Information.ReportAPC PDU2 NPS Devices General Information ReportSCUtils.APC.PDU2.NPS.Device.General.Information.ReportMicrosoft.SystemCenter.DataWarehouse.Report.CustomConfigurationSCUtils.APC.PDU2.DevicePublicTrue
SCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusCurrent.ReportAPC PDU2 Outlet current draw, in Amps, ReportSCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusCurrent.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.OutletMeteredPublicTrue
SCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusEnergy.ReportAPC PDU2 Outlet load energy consumption, in kilowatt-hours, ReportSCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusEnergy.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.OutletMeteredPublicTrue
SCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusPower.ReportAPC PDU2 Power draw of the load ReportSCUtils.APC.PDU2.OutletMetered.Rule.rPDU2OutletMeteredStatusPower.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.OutletMeteredPublicTrue
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusApparentPower.ReportAPC PDU2 Phase load apparent power, in kiloVoltAmps (kVA), ReportSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusApparentPower.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.PhasePublicTrue
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusCurrent.ReportAPC PDU2 Phase current draw, in Amps, ReportSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusCurrent.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.PhasePublicTrue
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPower.ReportAPC PDU2 Phase load power, in kilowatts (kW), ReportSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPower.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.PhasePublicTrue
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPowerFactor.ReportAPC PDU2 Phase load power factor ReportSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusPowerFactor.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.PhasePublicTrue
SCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusVoltage.ReportAPC PDU2 Phase Voltage, in Volts, ReportSCUtils.APC.PDU2.Phase.Rule.rPDU2PhaseStatusVoltage.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.PhasePublicTrue
SCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusRelativeHumidity.ReportAPC PDU2 Sensor humidity reading in percent relative humidity ReportSCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusRelativeHumidity.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.SensorPublicTrue
SCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempC.ReportAPC PDU2 Sensor temperature reading, in degrees Celsius, ReportSCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempC.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.SensorPublicTrue
SCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempF.ReportAPC PDU2 Sensor temperature reading, in degrees Fahrenheit, ReportSCUtils.APC.PDU2.Sensor.Rule.rPDU2SensorTempHumidityStatusTempF.ReportMicrosoft.SystemCenter.DataWarehouse.Report.PerformanceSCUtils.APC.PDU2.SensorPublicTrue