Fujitsu PRIMERGY Out-Of-Band Server - Power Management Tasks

Fujitsu.Servers.PRIMERGY.OutOfBand.PowerMgmtTask :: 8.2.0.0 (Management Pack)

Fujitsu PRIMERGY Out-Of-Band Server - Power Management Tasks. This Management Pack provides additional tasks to perform Power Management (Server Power On/Off, Server Reset) via the embedded iRMC of the Fujitsu Out-Of-Band Server.

Summary

Fujitsu PRIMERGY Out-Of-Band Server - Power Management Tasks Management Pack

Copyright (C) Fujitsu Technology Solutions 2016

This Management Pack contains additional task definitions to perform Power Management operations like server power on, power off, server reset etc. via the embedded iRMC of the Fujitsu Out-Of-Band Server.

Related Links

Fujitsu Servers Integration for Server Management Solutions

Management Pack Elements

WriteAction Modules (1)

 DisplayNameIDIsolationAccessibility
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcPowerManagementWriteActionModuleTypeBMC Power Management Write Action Module TypeFujitsu.Servers.PRIMERGY.OutOfBand.BmcPowerManagementWriteActionModuleTypeAnyInternal

Agent Tasks (12)

 DisplayNameIDTargetAccessibilityCategoryEnabled
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerPowerCycleRemote Server Power CycleFujitsu.Servers.PRIMERGY.OutOfBand.BmcServerPowerCycleFujitsu.Servers.PRIMERGY.OutOfBand.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerPowerOffRemote Server Power OffFujitsu.Servers.PRIMERGY.OutOfBand.BmcServerPowerOffFujitsu.Servers.PRIMERGY.OutOfBand.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerPowerOnRemote Server Power OnFujitsu.Servers.PRIMERGY.OutOfBand.BmcServerPowerOnFujitsu.Servers.PRIMERGY.OutOfBand.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerRequestRebootRequest Server Reboot (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerRequestRebootFujitsu.Servers.PRIMERGY.OutOfBand.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerRequestShutdownRequest Server Shutdown (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerRequestShutdownFujitsu.Servers.PRIMERGY.OutOfBand.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcServerResetRemote Server ResetFujitsu.Servers.PRIMERGY.OutOfBand.BmcServerResetFujitsu.Servers.PRIMERGY.OutOfBand.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.ServerPowerCycleRemote Power CycleFujitsu.Servers.PRIMERGY.OutOfBand.ServerPowerCycleFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.ServerPowerOffRemote Power OffFujitsu.Servers.PRIMERGY.OutOfBand.ServerPowerOffFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.ServerPowerOnRemote Power OnFujitsu.Servers.PRIMERGY.OutOfBand.ServerPowerOnFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.ServerRequestRebootRequest Reboot (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.ServerRequestRebootFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.ServerRequestShutdownRequest Shutdown (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.ServerRequestShutdownFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.ServerResetRemote Hard ResetFujitsu.Servers.PRIMERGY.OutOfBand.ServerResetFujitsu.Servers.PRIMERGY.OutOfBand.ServerPublicCustomTrue