Fujitsu PRIMERGY Out-Of-Band Server - Power Management Tasks

Fujitsu.Servers.PRIMERGY.OutOfBand.PowerMgmtTask :: 8.5.2.0 (Management Pack)

This Management Pack provides additional tasks to perform Power Management (Server Power On/Off, Server Reset) via the embedded iRMC of the Fujitsu Out-Of-Band Server.

Summary

Fujitsu PRIMERGY Out-Of-Band Server - Power Management Tasks Management Pack

Copyright 2015-2018 FUJITSU LIMITED

This Management Pack contains additional task definitions to perform Power Management operations like server power on, power off, server reset etc. via the embedded iRMC of the Fujitsu Out-Of-Band Server.

Related Links

Fujitsu Servers Integration for Server Management Solutions

Management Pack Elements

WriteAction Modules (1)

 DisplayNameIDIsolationAccessibility
Fujitsu.Servers.PRIMERGY.OutOfBand.BmcPowerManagementWriteActionModuleTypeBMC Power Management Write Action Module TypeFujitsu.Servers.PRIMERGY.OutOfBand.BmcPowerManagementWriteActionModuleTypeAnyInternal

Agent Tasks (12)

 DisplayNameIDTargetAccessibilityCategoryEnabled
Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.PowerCycleRemote Server Power CycleFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.PowerCycleFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.PowerOffRemote Server Power OffFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.PowerOffFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.PowerOnRemote Server Power OnFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.PowerOnFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.RequestRebootRequest Server Reboot (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.RequestRebootFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.RequestShutdownRequest Server Shutdown (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.RequestShutdownFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.iRMC.ResetRemote Server ResetFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.ResetFujitsu.Servers.PRIMERGY.OutOfBand.iRMC.iRMCDeviceInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.Server.PowerCycleRemote Power CycleFujitsu.Servers.PRIMERGY.OutOfBand.Server.PowerCycleFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.Server.PowerOffRemote Power OffFujitsu.Servers.PRIMERGY.OutOfBand.Server.PowerOffFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.Server.PowerOnRemote Power OnFujitsu.Servers.PRIMERGY.OutOfBand.Server.PowerOnFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.Server.RequestRebootRequest Reboot (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.Server.RequestRebootFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.Server.RequestShutdownRequest Shutdown (requires ServerView Agents)Fujitsu.Servers.PRIMERGY.OutOfBand.Server.RequestShutdownFujitsu.Servers.PRIMERGY.OutOfBand.ServerInternalCustomTrue
Fujitsu.Servers.PRIMERGY.OutOfBand.Server.ResetRemote Hard ResetFujitsu.Servers.PRIMERGY.OutOfBand.Server.ResetFujitsu.Servers.PRIMERGY.OutOfBand.ServerPublicCustomTrue